NCIDQ IDPX
Liberty University
Here are the best resources to pass NCIDQ IDPX. Find NCIDQ IDPX study guides, notes, assignments, and much more.
All 15 results
Sort by:
-
Exam (elaborations)
NCIDQ-PX EXAM| 210 QUESTIONS| WITH COMPLETE SOLUTIONS
-
--19November 20222022/2023A+Available in bundle
- Door openings must be a minimum of how many inches wide? Correct Answer: minimum of 36" 
 
The height of a door must not be less than what height? Correct Answer: minimum of 7'H 
 
Common path of egress travel distance must not exceed what length, measured along the path of travel? Correct Answer: 250' in length 
 
Common path of egress travel distance must not exceed what length? Correct Answer: 100' in length 
 
An accessible route with clear width less than 60" shall provide passing ...
-
$10.99 More Info
Classroom
-
Exam (elaborations)
NCIDQ – PX exam QUESTIONS WITH COMPLETE SOLUTIONS
-
--23November 20222022/2023A+Available in bundle
- What is building commissioning? Correct Answer: This is the process of inspecting, testing, starting up, and adjusting building systems and then verifying that the systems are operating as intended and that they meet the design criteria. 
 
how does an independent furniture rep differ from a manufacturer's rep? Correct Answer: This type of furniture representative is self-employed and may represent more than one manufacturer. 
 
What type of schedule is this? Correct Answer: This is a graphi...
-
$10.99 More Info
Classroom
-
Exam (elaborations)
NCIDQ Practicum| 208 questions| with complete solutions
-
--20November 20222022/2023A+Available in bundle
- Net Area/Net Assignable Area Correct Answer: The actual area required by a client to accommodate specified functions. Includes interior walls and building columns. DOES NOT include corridor circulation, closets, etc. 
 
Efficiency Factor Correct Answer: Also called "Circulation Area". It is the ratio of enclosed spaces (offices) to open spaces (workstations). 
 
Circulation Area= NSF/ Circulation Multiplier 
 
Useable Area (USF) Correct Answer: Also called the "occupant area" and excludes...
-
$9.99 More Info
Classroom
-
Exam (elaborations)
NCIDQ IDPX 184 questions with complete solutions
-
--16November 20222022/2023A+Available in bundle
- What is a design concept Correct Answer: This is an idea or statement concerning an overall physical response to ideas developed during programming 
 
What does the Certificate of Occupancy letter provide? Correct Answer: This letter is issued by the AHJ and allows the client to occupy a building or portion of a building after the final inspection 
 
What is the primary model building code used in the US? Correct Answer: The International Building Code (IBC) 
 
In the US, what document gives ...
-
$10.99 More Info
Classroom
-
Exam (elaborations)
NCIDQ IDPX - Codes and Standards Exam Questions with COMPLETE SOLUTION
-
--5November 20222022/2023A+Available in bundle
- What are the four stages of a product's life cycle? - The stages of this process include: - raw material acquisition - manufacturing - use and maintenance - disposal What is embodied energy? - This is the energy required by a product or material for its extraction as a raw material, initial processing, and subsequent manufacture into a finished product. In terms of its sustainability, what are the primary advantages and disadvantages of aluminum as a construction material? - This material has h...
-
$7.99 More Info
Classroom
-
Exam (elaborations)
NCIDQ RANDOM EXAM 148 QUESTIONS WITH COMPLETE SOLUTIONS
-
--11November 20222022/2023A+Available in bundle
- The common lab of egress travel distance can not exceed...? Correct Answer: 100' 
 
How high can a light switch be mounted? Correct Answer: 48" 
 
What is the min distance between a double door vestibule? Correct Answer: 48" plus the width of the door(s) at 90 degrees 
 
What is the equation for number of fire extinguishers in a space? Correct Answer: 1 per every 3000sf 
 
How much fabric is required to create drapery with a fullness of 150%? Correct Answer: 2.5 times finished fabric wid...
-
$10.99 More Info
Classroom
-
Exam (elaborations)
NCIDQ IDPX – Fall Exam Questions Bank with COMPLETE SOLUTION
-
--23November 20222022/2023A+Available in bundle
- The 3-part technical sections in the CSI MasterFormat specs refer to: Correct Answer: general, products, execution 
 
What is the typical term used to describe the furniture sales agreement between the client and interior designer? Correct Answer: proposal 
 
Which veneer cut would result in the least veneer waste, but be the least desirable to use for the table? Correct Answer: rotary slicing 
 
When estimating how much fabric will be required for custom designed draperies, which needs to be...
-
$12.99 More Info
Classroom
-
Exam (elaborations)
NCIDQ – IDPX EXAM| 232 QUESTIONS| WITH COMPLETE SOLUTIONS
-
--50November 20222022/2023A+Available in bundle
- A: Door Schedule 
Where would it be best to call out the frame material on an entry door? 
A. door schedule 
B. finish schedule 
C. hardware schedule 
D. finish plan 
A: 'I' should be used for interior design sheets when an architect's drawings are included as part of the drawing set 
 
'I' is most commonly used when architectural drawings are also included in a drawing set, as a means to easily distinguish between architectural and interiors work. 
When would be most appropriate for an int...
-
$12.99 More Info
Classroom
-
Exam (elaborations)
NCIDQ IDPX EXAM| 182 QUESTIONS WITH COMPLETE SOLUTIONS
-
--18November 20222022/2023A+Available in bundle
- In regard to interior design, what is a guard, and what dimension must it have in commercial construction? This is a building component installed to prevent falls from an elevated area. Its required minimum heights 42" AFF 
 
What is fire resistance-rated glazing? This is glass or some other glazing material that has been tested according to ASTM E119 as part of a fire-resistance-rated wall assembly 
 
How many construction types are there, and which has the highest fire resistance? The are fiv...
-
$10.99 More Info
Classroom
-
Exam (elaborations)
NCIDQ - CODES & STANDARDS
-
--6November 20222022/2023A+Available in bundle
- 16 CFR 1201 - safety standard for architectural glazing materials 
 
40 CFR 50 - National ambient air quality standards 
 
40 CFR 59 - National volatile organic compound emission standards for consumer and commercial products 
 
ADA/ABA Guidelines - American with Disabilities Act and Architectural Barriers Act Accessibility Guidelines 
 
ANSI A108 - Specifications for Installation of ceramic tile 
 
ANSI Z97.1 - Safety glazing materials used in buildings - Safety performance specifications and m...
-
$4.99 More Info