- What action below would be most in keeping with the ALARA principle while performing a diagnostic ultrasound examination? 
A: Allow multiple students to scan an obstetrical patient because the fetus is in a good position for imaging. 
B: Prolong the sonogram to make videos of the fetus for each family member. 
C: Complete the diagnostic scan in a timely fashion at the lowest output power that achieves a quality image. 
D: Maximize the acoustic output to brighten the overall image. 
E: Extend...
-
$12.99 Meer Info
Demetrius
-
Tentamen (uitwerkingen)
Davies SPI REVIEW print part 2| 500 questions| with complete solutions
-
--62februari 20232022/2023A+Beschikbaar in een bundel
- In order for distance measurements to be accurate in an ultrasound tissue phantom, the phantom sound propagation speed must be: 
A: 13 us/cm 
B: 1.54 m/s 
C: 154o m/s 
D: 1/2 the speed of sound in tissue 
E: Twice the speed of sound in soft tissue CORRECT ANSWERS: C: 1540 m/s 
 
You expanded the image sector width to improve visualization of a large mass. What can you do to maintain the same temporal resolution you had before your adjustment? 
A: Increase the digitization bit depth 
B: In...
-
$15.99 Meer Info
Demetrius
-
Tentamen (uitwerkingen)
DAVIES SPI: II. Physical Principles (20% of ARDMS)
-
--31februari 20232022/2023A+Beschikbaar in een bundel
- You have increased the transmit power while performing a pelvic ultrasound examination. This action increases which of the following? 
 
A. Penetration 
B. Acoustic power 
C. Image brightness 
D. Voltage applied to the transducer elements 
E. All of the above CORRECT ANSWERS: E. All of the above 
 
Attenuation of the sound beam increases with increasing: 
 
A. Path length 
B. Absorption 
C. Frequency 
D. Scattering and reflection 
E. All of the above CORRECT ANSWERS: E. All of the above 
...
-
$12.99 Meer Info
Demetrius
-
Tentamen (uitwerkingen)
Davies SPI 153 questions with complete solutions
-
--11februari 20232022/2023A+Beschikbaar in een bundel
- Interference patterns of reflected waves causes? CORRECT ANSWERS: acoustic speckle 
 
which of the following terms denotes the time it takes for one cycle to occur? CORRECT ANSWERS: Period 
 
which of the following increases as frequency increases? CORRECT ANSWERS: absorption 
scattering 
attenuation 
 
What is meant by the dead zone in performance testing? CORRECT ANSWERS: Distance from the transducer to the first identifiable echo. 
 
What sound-tissue interaction is necessary to form an u...
-
$12.99 Meer Info
Demetrius
-
Tentamen (uitwerkingen)
SPI Review Questions – Davies| 120 questions| with complete solutions
-
--8februari 20232022/2023A+Beschikbaar in een bundel
- Will not cause a redirection of part of the ultrasound energy CORRECT ANSWERS: absorption 
 
You are scanning a large mass composed primarily of fat. What will you most likely encounter? CORRECT ANSWERS: axial misregistration of object distal to the mass on the screen due to the slower propagation speed through fat 
 
What 2 conditions must be present to cause a refraction in soundwave? CORRECT ANSWERS: oblique incidence and 
change in propagation speed 
 
What may be detected with refraction...
-
$12.99 Meer Info
Demetrius
-
Tentamen (uitwerkingen)
Spi Davies Spi Davies| 618 questions| 172 pages| with complete solutions
-
--172februari 20232022/2023A+Beschikbaar in een bundel
- What action below would be most in keeping with the ALARA principle while performing a diagnostic ultrasound examination? 
 
A. Allow multiple students to scan an obstetrical patient because the fetus is in a good position for imaging. 
 
B. Prolong the sonogram to make videos of the fetus for each family member. 
 
C. Complete the diagnostic scan in a timely fashion at the lowest output power that achieves a quality image. 
 
D. Maximum the acoustic output to brighten the overall image. 
 
E. E...
-
$15.49 Meer Info
Demetrius
-
Tentamen (uitwerkingen)
Davie's SPI Review| 304 questions| with complete solutions
-
--21februari 20232022/2023A+Beschikbaar in een bundel
- This converter converts the numbers stored in memory to proportional voltages that control the brightness on a CRT monitor CORRECT ANSWERS: Digital to Analog Converter 
 
The Digital Scan Converter is AKA: CORRECT ANSWERS: Image Memory 
 
This is where images are stored in the ultrasound system: CORRECT ANSWERS: Scan Converter 
 
The system component which is most responsible for transmit focusing: CORRECT ANSWERS: Beam Former 
 
The process of filling in the empty spaces between scan lines:...
-
$13.49 Meer Info
Demetrius
-
Tentamen (uitwerkingen)
DAVIES SPI REVIEW| 129 questions| with complete solutions
-
--9februari 20232022/2023A+Beschikbaar in een bundel
- Which of the following helps to improve the elevation resolution to B- mode image? correct answers Focusing with and acoustic lens 
 
During and exam, you encounter all of the interactions of ultrasound and tissue listed. Which one will NOT cause redirection of part of the ultrasound energy? correct answers Absorption 
 
When you adjust the TGC component of the ultrasound system implements the changes? correct answers Receiver 
 
Which is NOT true about lateral resolution? correct an...
-
$12.99 Meer Info
Demetrius
-
Tentamen (uitwerkingen)
Davies SPI REVIEW| 1707 questions| 178 pages| verified answers
-
--178februari 20232022/2023A+Beschikbaar in een bundel
- What action below would be most in keeping with the ALARA principle while performing a diagnostic ultrasound examination? 
A: Allow multiple students to scan an obstetrical patient because the fetus is in a good position for imaging. 
B: Prolong the sonogram to make videos of the fetus for each family member. 
C: Complete the diagnostic scan in a timely fashion at the lowest output power that achieves a quality image. 
D: Maximize the acoustic output to brighten the overall image. 
E: Extend...
-
$17.49 Meer Info
Demetrius
-
Tentamen (uitwerkingen)
SPI Registry| 80 questions| with complete solutions
-
--6februari 20232022/2023A+Beschikbaar in een bundel
- All numerical values should have corresponding _____. CORRECT ANSWERS: units 
 
An ______ tool can be used to measure area CORRECT ANSWERS: ellipse 
 
_________ is not a unit. CORRECT ANSWERS: Percent 
 
Giga CORRECT ANSWERS: billion 
10^9 
G 
 
micro CORRECT ANSWERS: millionth 
10^-6 
 
How many hertz is 3MHz? 
a. 3,000,000 
b. 3,000 
c. 333 
d. 0.003 CORRECT ANSWERS: 3,000,000 
 
How much bigger is a billion than a million? 
a. 10 times 
b. 100 times 
c. 1,000 times 
d. 500 times CORREC...
-