Electrician's Licensing Exam Questions And Answers 100% Verified
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Electrician's Licensing Exam Questions And 
Answers 100% Verified 
NEC Article ______ defines breakers and fuses. - answerAccording to NEC Article 100, a 
device that opens and closes a circuit by nonautomatic means automatically closes for a 
predetermined overcurrent. 
Annex _____ of NEC covers conduit fill. - answerAnnex C of NEC covers conduit and tubing 
fill for conductors and fixture wire fill. 
NEMA stands for National Electrical Manufacturers Association - answerTrue - NEMA is the 
acr...
-
NEC 2011 Journeyman Electrical Exam Study Guide (Michigan)
- Exam (elaborations) • 23 pages • 2024
-
Available in package deal
-
- $9.99
- + learn more
NEC 2011 Journeyman Electrical Exam 
 
Study Guide (Michigan) 
 
Grounding and Bonding: 
 
Where outside, aluminum or copper-clad aluminum grounding electrode conductors shall not be 
terminated within ____in. of Earth. 
 
A. 12 in. 
B. 18 in. 
C. 24 in. 
D. 36 in. 
- B. 18 in. 
250.64(A) 
Temporary Installations: 
 
When used by personnel during construction, remodeling, maintenance repair, or demolition of a 
building, GFCI (ground fault circuit interrupter) protection is required for all 125 ...
-
Mike Holt 250 Complete Questions And Answers With Verified Solutions
- Exam (elaborations) • 17 pages • 2023
-
Available in package deal
-
- $13.49
- + learn more
Mike Holt 250 Complete Questions And Answers With Verified Solutions 
A grounding electrode shall be required if a building or structure is supplied by a feeder. Correct Answer: True 
 
Metal enclosures shall be permitted to be used to connect bonding jumpers and _____, or both, together to become a part of an effective ground-fault current path. Correct Answer: equipment grounding conductors. 
 
The grounding electrode conductor shall be permitted to be run to any _____ available in the groundi...
-
Electrician's Licensing Exam Questions And Answers 100% Verified
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Electrician's Licensing Exam Questions And 
Answers 100% Verified 
NEC Article ______ defines breakers and fuses. - answerAccording to NEC Article 100, a 
device that opens and closes a circuit by nonautomatic means automatically closes for a 
predetermined overcurrent. 
Annex _____ of NEC covers conduit fill. - answerAnnex C of NEC covers conduit and tubing 
fill for conductors and fixture wire fill. 
NEMA stands for National Electrical Manufacturers Association - answerTrue - NEMA is the 
acr...
-
Electrical Journeyman Test Study Guide
- Exam (elaborations) • 26 pages • 2024
-
Available in package deal
-
- $9.99
- + learn more
Electrical Journeyman Test Study Guide 
 
A fixed light will be allowed to be 30 amp provided the socket is rated ____ duty. 
a. Light 
b. Medium 
c. Heavy 
d. Extra Heavy - c. Heavy 
 
From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in 
subsection (3), and individual other than an individual who is licensed under this article and 
______________ working under the direction of a holder of an electrical contractors licence, 
shall not in any manner underta...
Want to regain your expenses?
-
IEC First Year Exam Study Guide Questions with Verified Solutions
- Exam (elaborations) • 11 pages • 2024
-
Available in package deal
-
- $9.99
- + learn more
IEC First Year Exam Study Guide 
Questions with Verified Solutions 
 
___ can be described as the point of demarcation between where the serving utility ends and the 
premises wiring begins. Service Point 
 
A 12/3 cable is installed from a 120/240-V, 1Ø panel and feeds a split-wired duplex receptacle. 
One "hot" is connected to a 20A breaker in panel space 1. The second "hot" is connected to a 
20A breaker in space 3. A 16-amp load is connected to the upper receptacle and a 14-amp load is ...
-
Residential Wireman Electrical Exam - Larry Bobo Questions And Answers Rated A+
- Exam (elaborations) • 15 pages • 2024
- Available in package deal
-
- $7.49
- + learn more
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase 
underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG 
copper to 1 AWG copper is __ AWG copper 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 - Answer-4 
The continuity of the grounded conductor shall depend on a busbar or __ only. 
Continuity, Grounded conductors 
200.12 - Answer-wire. 
Each multi-wire branch circuit shall be provided with a means t...
-
Journeyman Electrician #5 | Questions and Correct Answers | Latest Update 2024/2025 | Graded A+
- Exam (elaborations) • 13 pages • 2024
- Available in package deal
-
- $11.99
- + learn more
Journeyman Electrician #5 | 
Questions and Correct Answers | 
Latest Update 2024/2025 | 
Graded A+ 
Unless listed and identified otherwise, terminations and conductors of 
sizes 14 AWG through 1 AWG shall be rated at _____. 
a) 75°C 
b) 75°F 
c) 90°C 
d) 60°C - Answer -D: 60°C 
Ref: 110.14(C)(1)(a)(1) 
The MINIMUM size copper equipment bonding jumper on the supply 
side of a service consisting of parallel copper phase conductors with a 
total circular mil area of 2000 kcmil shall be ____.a)...
-
Journeyman Open Book Practice Exam | Questions with 100% Correct Answers | Latest Update 2024 | Verified
- Exam (elaborations) • 9 pages • 2024
-
- $9.99
- + learn more
Journeyman Open Book Practice Exam | Questions with 100% Correct Answers | Latest Update 2024 | Verified 
where extensive metal in or on buildings or structures may become energized and is subject to 
personal contact _______ will provide additional safety. 
a) adequate bonding and grounding 
b) bonding 
c) suitable ground detectors 
d) none of these - a) adequate bonding and grounding 
single conductor cables shall be ______ or larger and shall be of a type listed for use in cable 
trays. 
(a) ...
-
BICSI - Installer 1 - Review ALL ANSWERS 100% CORRECT SPRING FALL-2023/24 EDITION GUARNTEED GRADE A+
- Exam (elaborations) • 29 pages • 2023
-
- $14.99
- 1x sold
- + learn more
B 
A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______? 
 
A 5 m (16.5') 
B 10 m (33') 
C 15 m (50') 
D 30 m (100') 
C 
Which of the following is a property of an electromagnetic field built around a conductor that opposes any changes in current flow in a circuit? 
 
A Impedance 
 
B Capacitance 
 
C Inductance 
 
D Resistance 
A 
Which of the following markings is used for non-conductive optical fiber general-purpose cables? 
 
A OFNG 
 
B OFCR 
 
C OF...