EFM NCC Exam Study Guide
- Exam (elaborations) • 17 pages • 2024
-
Available in package deal
-
- $9.99
- + learn more
EFM NCC Exam Study Guide 
 
Why use fetal monitoring? - Primary goal is to prevent fetal and maternal morbidity and 
mortality (prevent injury and death to mother and/ or baby), to prevent bad patient outcomes. 
 
What percent of babies who experience a suboptimal event while being fetal monitored, develop 
cerebral palsy? - 3% of babies with poor tracing develop cerebral palsy 
 
What are most sentinel events due to? - Poor communication between providers. Most errors 
are traceable back to com...
-
CEFM Practice Test Questions And Answers
- Exam (elaborations) • 12 pages • 2024
- Available in package deal
-
- $11.99
- + learn more
CEFM Practice Test Questions And Answers 
 
 
The paper speed used with EFM in North America is: 
a. 1cm/min 
b. 2cm/min 
c. 3cm/min - ANS C. 3cm/min 
 
The US transducer on the EFM measures the 
a. Electrical signal of the fetal heart 
b. Mechanical movement of the fetal heart reflected off of sound waves 
c. R to R intervals of the fetal heart - ANS b. Mechanical movement of the fetal heart reflected off of sound waves 
 
The purpose of the autocorrelation in external monitoring is to 
...
-
CEFM Practice Test
- Exam (elaborations) • 19 pages • 2024
-
Available in package deal
-
- $9.99
- + learn more
CEFM Practice Test 
 
The paper speed used with EFM in North America is: 
a. 1cm/min 
b. 2cm/min 
c. 3cm/min - C. 3cm/min 
 
The US transducer on the EFM measures the 
a. Electrical signal of the fetal heart 
b. Mechanical movement of the fetal heart reflected off of sound waves 
c. R to R intervals of the fetal heart - b. Mechanical movement of the fetal heart reflected off 
of sound waves 
 
The purpose of the autocorrelation in external monitoring is to 
a. Compare incoming waveforms for comp...
-
NCC EFM Electronic Fetal Monitoring Certification Exam Questions and Answers Latest Updated 2024/2025 Graded A+.
- Exam (elaborations) • 14 pages • 2024
- Available in package deal
-
- $14.49
- + learn more
NCC EFM Electronic Fetal Monitoring Certification Exam Questions and Answers Latest Updated 2024/2025 Graded A+. Content on exam --------- CORRECT ANSWER ----- -Pattern recognition & intervention: 
70% 
-Physiology: 11% 
-Fetal assessment methods: 9% 
-EFM equipment: 5% 
-Professional issues: 5% 
Pattern recognition & intervention --------- CORRECT ANSWER ----- -FHR baseline 
-FHR variability 
-FHR accelerations 
-FHR decelerations 
-Normal uterine activity 
-Abnormal uterine activity 
-Fe...
-
CEFM Final Exam Well Answered Graded A+ 2024.
- Exam (elaborations) • 14 pages • 2024
-
Available in package deal
-
- $9.99
- + learn more
The paper speed used with EFM in North America is: 
a. 1cm/min 
b. 2cm/min 
c. 3cm/min - Answer C. 3cm/min 
 
The US transducer on the EFM measures the 
a. Electrical signal of the fetal heart 
b. Mechanical movement of the fetal heart reflected off of sound waves 
c. R to R intervals of the fetal heart - Answer b. Mechanical movement of the fetal heart reflected off of sound waves 
 
The purpose of the autocorrelation in external monitoring is to 
a. Compare incoming waveforms for compariso...
Want to regain your expenses?
-
CEFM Practice Test | Questions with 100% Correct Answers | Verified | Latest Update 2024
- Exam (elaborations) • 14 pages • 2023
-
- $15.49
- + learn more
The paper speed used with EFM in North America is: 
a. 1cm/min 
b. 2cm/min 
c. 3cm/min - C. 3cm/min 
The US transducer on the EFM measures the 
a. Electrical signal of the fetal heart 
b. Mechanical movement of the fetal heart reflected off of sound waves 
c. R to R intervals of the fetal heart - b. Mechanical movement of the fetal heart reflected off of 
sound waves 
The purpose of the autocorrelation in external monitoring is to 
a. Compare incoming waveforms for comparison 
b. Decrease signal...
-
CEFM Exam Study Guide | Questions with 100% Correct Answers | Verified | Latest Update 2024
- Exam (elaborations) • 30 pages • 2024
-
- $13.49
- + learn more
Describe Fetal Heart Rate Monitoring - EFM may be external, internal or a combination 
In the US, the majority of women have EFM during some or all of their labors 
Each modality has both pros and cons 
Describe Doppler Ultrasound - The doppler US transducer is used to assess FHR characteristics and 
patterns. The transducer translates sound wave reflections into waveforms which are interpreted by a 
computer and then exported as an audible sound and a waveform pattern. 
Problems: FHR artifact, ...
-
Nursing Care During Labor & Delivery (Test 2) Questions With Complete Solution
- Exam (elaborations) • 30 pages • 2024
- Available in package deal
-
- $14.49
- + learn more
Nursing Care During Labor & Delivery (Test 2) 
Questions With Complete Solution 
nursing assessment - Answer->upon admission to L/D: 
-review prenatal records; note any risk factors and areas of concern/need 
-obtain admission data (age, GTPAL, EDC, ROM) 
true vs false labor 
fetal activity 
current meds/allergies 
prenatal problems 
bloody show vs bleeding 
onset of labor/pattern of UC 
CB prep/birth plan 
feeding method 
pediatrician choice 
last food/fluid ingested 
last void/BM 
recent sl...
-
CEFM Practice Test Questions And Correct Answers 2024.
- Exam (elaborations) • 14 pages • 2024
-
Available in package deal
-
- $7.99
- + learn more
The paper speed used with EFM in North America is: 
a. 1cm/min 
b. 2cm/min 
c. 3cm/min - Answer C. 3cm/min 
 
The US transducer on the EFM measures the 
a. Electrical signal of the fetal heart 
b. Mechanical movement of the fetal heart reflected off of sound waves 
c. R to R intervals of the fetal heart - Answer b. Mechanical movement of the fetal heart reflected off of sound waves 
 
The purpose of the autocorrelation in external monitoring is to 
a. Compare incoming waveforms for compari...
-
CEFM Exam Study Guide | Questions with 100% Correct Answers | Verified | Latest Update 2024 | 30 Pages
- Exam (elaborations) • 30 pages • 2023
-
- $20.49
- + learn more
Describe Fetal Heart Rate Monitoring - EFM may be external, internal or a combination 
In the US, the majority of women have EFM during some or all of their labors 
Each modality has both pros and cons 
Describe Doppler Ultrasound - The doppler US transducer is used to assess FHR characteristics and 
patterns. The transducer translates sound wave reflections into waveforms which are interpreted by a 
computer and then exported as an audible sound and a waveform pattern. 
Problems: FHR artifact, ...