1.	On low pressure chillers, moisture typically enters the refrigerant system through *correct answer*air leaks from areas with gaskets or fittings 
2.	The maximum test pressure for leak testing a low pressure centrifugal is: *correct answer*10 psig 
3.	Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller *correct answer*...
![EPA 608 Type 3 exam with 100% Complete Solutions (Latest 2024/2025)](/docpics/5603290/666745080bf5a_5603290_121_171.jpeg)
-
EPA 608 Type 3 exam with 100% Complete Solutions (Latest 2024/2025)
- Exam (elaborations) • 16 pages • 2024
- Available in package deal
-
STUDYCENTER2024
-
- $13.49
- + learn more
EPA 608 Type 3 exam with 100% Complete Solutions (Latest 2024/2025)The maximum test pressure for leak testing a low pressure centrifugal is: 
10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on 
CFC-11 chiller 
... 
A hydrostatic tube test kit is used to: 
determine if a tube leaks 
Commercial and industrial process refrigeration systems must be repaired when 
the leak rate exceeds ____ of the charge per year. 
35% 
Refrigerant recovery typically start with ...
![(Answered) EPA SECTION 608 CORE (2021-2022 revision)](/docpics/638d2d42da532_2155145.jpg)
-
(Answered) EPA SECTION 608 CORE (2021-2022 revision)
- Exam (elaborations) • 20 pages • 2022
-
Available in package deal
-
dennys
-
- $9.99
- 2x sold
- + learn more
EPA SECTION 608 CORE (2021-2022 revision) 
A disposable cylinder should be reduced to what pressure before scrapping? 
a. 0 psig 
b. 20 psig 
c. 50 psig 
d. 80 psig 
 
A major system repair is being performed on a R-22 appliance. What CANNOT be done to recharge the appliance? 
a. Add R-22 after the repair is complete. 
b. Retrofit the unit to R-407C. 
c. Use recovered or recycled R-22 from the same 
owner. 
d. Top off the unit with R-410a. 
A refillable cylinder must not be filled above what ...
![EPA 608 Type 3 Exam Questions And Answers](/docpics/5461786/6655c963c7685_5461786_121_171.jpeg)
-
EPA 608 Type 3 Exam Questions And Answers
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
Studyclock
-
- $10.99
- + learn more
EPA 608 Type 3 Exam Questions And Answers 
 
 
On low pressure chillers, moisture typically enters the refrigerant system through - ANS air leaks from areas with gaskets or fittings 
 
The maximum test pressure for leak testing a low pressure centrifugal is: - ANS 10 psig 
 
Leak test and repair the chiller to reduce refrigerant loss from a purge unit on CFC-11 chiller - ANS ... 
 
A hydrostatic tube test kit is used to: - ANS determine if a tube leaks 
 
Commercial and industrial proce...
![EPA 608 (TYPE II) Exam Test with Verified Answers Graded A](/docpics/6936641/677b4ef0cd4ef_6936641_121_171.jpeg)
-
EPA 608 (TYPE II) Exam Test with Verified Answers Graded A
- Exam (elaborations) • 8 pages • 2025
-
MERCYTRISHIA
-
- $10.79
- + learn more
EPA 608 (TYPE II) Exam Test with Verified Answers Graded A 
1. Pressurize the system with 
an inert gas & leak check. 
2. Pressurized with nitrogen 
then leak checked. 
3. 15% 
4. 400 psig 
5. Condensed by the recovery 
system. 
6. Recover as much R-502 
from the recovery unit as 
possible, change filter, & 
evacuate. 
7. Receiver 
8. 120 psig 
9. 1.) Acids 
2.) Moisture 
3.) Oils 
When a new system has been assembled, the 
first thing to do is? 
After installation of a field-piped R-410A split ...
![EPA 608 Type 3 Exam Questions with 100% Correct Answers | Verified | Latest Update 2024| Rated A+](/docpics/4950169/6614154385f22_4950169_121_171.jpeg)
-
EPA 608 Type 3 Exam Questions with 100% Correct Answers | Verified | Latest Update 2024| Rated A+
- Exam (elaborations) • 19 pages • 2024
- Available in package deal
-
oneclass
-
- $12.44
- + learn more
EPA 608 Type 3 Exam Questions with 
100% Correct Answers | Verified | Latest 
Update 2024| Rated A+ 
On low pressure chillers, moisture typically enters the refrigerant system through air 
leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal is: 10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller 
... 
A hydrostatic tube test kit is used to: determine if a tube leaks 
Commercial and i...
![Bundle for Chlorofluorocarbons (CFC's) and Ozone Layer Exams Correctly Solved 2024 | 2025](/docpics/5598293/6666caba05ffd_5598293_121_171.jpeg)
-
Bundle for Chlorofluorocarbons (CFC's) and Ozone Layer Exams Correctly Solved 2024 | 2025
- Package deal • 12 items • 2024
-
AdelineJean
-
- $36.49
- + learn more
Bundle for Chlorofluorocarbons (CFC's) and Ozone Layer Correctly Solved 2024 | 2025 . Actual tests, C6 atmosphere, CFC exam, Practice tests, Type 1 CFC, cfc universal, air pollution, EPA 608 core, ODP test
![EPA 608 Type 3 exam with 100% Complete Solutions Latest 2024/2025 (Graded A+)](/docpics/5582275/666472704a356_5582275_121_171.jpeg)
-
EPA 608 Type 3 exam with 100% Complete Solutions Latest 2024/2025 (Graded A+)
- Exam (elaborations) • 16 pages • 2024
- Available in package deal
-
SOLUTIONS2024
-
- $12.99
- + learn more
EPA 608 Type 3 exam with 100% Complete Solutions Latest 2024/2025 (Graded A+) On low pressure chillers, moisture typically enters the refrigerant system through 
air leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal is: 
10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on 
CFC-11 chiller 
... 
A hydrostatic tube test kit is used to: 
determine if a tube leaks 
Commercial and industrial process re...
![EPA 608 Type 3 exam with 100% Complete Solutions Lates 2024-2025 (Graded A+)](/docpics/5608834/66681697127e1_5608834_121_171.jpeg)
-
EPA 608 Type 3 exam with 100% Complete Solutions Lates 2024-2025 (Graded A+)
- Exam (elaborations) • 16 pages • 2024
-
Available in package deal
-
STUDYLAB2023
-
- $12.49
- + learn more
EPA 608 Type 3 exam with 100% Complete Solutions Lates (Graded A+) On low pressure chillers, moisture typically enters the refrigerant system through 
air leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal is: 
10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on 
CFC-11 chiller 
... 
A hydrostatic tube test kit is used to: 
determine if a tube leaks 
Commercial and industrial process refrigeratio...
![EPA 608 Type 3 exam | Questions and Correct Solutions | Graded A+](/docpics/5999216/66bc979c4e605_5999216_121_171.jpeg)
-
EPA 608 Type 3 exam | Questions and Correct Solutions | Graded A+
- Exam (elaborations) • 16 pages • 2024
- Available in package deal
-
AdelineJean
-
- $12.49
- + learn more
EPA 608 Type 3 exam | Questions 
and Correct Solutions | Graded A+ 
On low pressure chillers, moisture typically enters the refrigerant 
system through - Answer -air leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal 
is: - Answer -10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge 
unit on CFC-11 chiller - Answer -... 
A hydrostatic tube test kit is used to: - Answer -determine if a tube leaks 