HVAC Electricity Exam Questions with Correct Answers.docx
- Exam (elaborations) • 4 pages • 2024
-
Available in package deal
-
- $12.49
- + learn more
HVAC Electricity Exam Questions with Correct A 
 
Amp Rating and Breaker size for - #14, #12, #10, #8, #6, #3 - Answer-14-15,15 
12-20,20 
10-30,30 
8-45,40 
6-65,60 
3-105,100 
 
Residential lighting and receptacle circuits use what type of wire? - Answer-14-2 AWG (14-gauge, 2-wire, plus bond) conductors 
 
Ampacity - Answer-The amount of current a conductor is rated to handle safely. 
 
NMD - Answer-Non-metallic-sheathed cable(dry) - for exposed wiring in dry or damp locations 
 
NMW - Answer-...
-
ADJUSTER PRO PRACTICE EXAM TEST DUE ON 2023-2024
- Exam (elaborations) • 49 pages • 2023
-
Available in package deal
-
- $19.99
- + learn more
ADJUSTER PRO PRACTICE EXAM TEST 
DUE ON 2023-2024 
John is doing some lawn maintenance using a steel blade on his weed-whacker. He 
fails to properly tighten the blade and it comes loose while he is trimming some tall 
grass at the edge of his property. The blade flies off towards his neighbor's house and 
crashes into the HVAC unit, severing the lines and effectively destroying the unit. Which 
coverage in John's homeowners policy might pay for the damage he caused to his 
neighbor's H...
-
PLUMBING BOOK MODULE 3 EXAM | QUESTIONS & ANSWERS (VERIFIED) | LATEST UPDATE | GRADED A+
- Exam (elaborations) • 31 pages • 2024
-
- $11.99
- + learn more
1 
PLUMBING BOOK MODULE 3 EXAM | 
QUESTIONS & ANSWERS (VERIFIED) | 
LATEST UPDATE | GRADED A+ 
In relation to aisles or places where people are walking, the tips of sharp tools that are 
lying on benches or tables should be pointed: 
Correct Answer: Away from the aisle 
Prevent rust on the metal parts of tools by applying 
Correct Answer: light oil 
To measure offsets, the plumber's rule has markings for 
Correct Answer: 45 degrees 
On the hacksaw, the more teeth per inch on a blade, 
Corre...
-
PLUMBING BOOK MODULE 3 EXAM | QUESTIONS & ANSWERS (VERIFIED) | LATEST UPDATE | GRADED A+
- Exam (elaborations) • 31 pages • 2024
-
- $12.99
- + learn more
1 
PLUMBING BOOK MODULE 3 EXAM | 
QUESTIONS & ANSWERS (VERIFIED) | 
LATEST UPDATE | GRADED A+ 
In relation to aisles or places where people are walking, the tips of sharp tools that are 
lying on benches or tables should be pointed: 
Correct Answer: Away from the aisle 
Prevent rust on the metal parts of tools by applying 
Correct Answer: light oil 
To measure offsets, the plumber's rule has markings for 
Correct Answer: 45 degrees 
On the hacksaw, the more teeth per inch on a blade, 
Corre...
-
559 Journeyman Mechanical Exam HVAC Complete Questions and Answers
- Exam (elaborations) • 4 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
559 Journeyman Mechanical Exam 
HVAC Complete Questions and Answers 
Which Type of air-conditoning system is most likely to leak refrigerant into a structure? 
Direct, Indirect, Evaporative or Split? - CORRECT ANSWER-Direct : 2015 IMC 
1103.3.2 
When mechanical equipment is located on a flat roof that is more than 30 inches above 
grade, how far from the roofs edge must the equipment be located before a guard rail is 
not needed? less than 6', 9', 4' or more than 10'? - CORRECT ANSWER-Mo...
Too much month left at the end of the money?
-
Adjuster Pro Questions and Answers 2022/2023
- Exam (elaborations) • 48 pages • 2023
- Available in package deal
-
- $15.49
- + learn more
John is doing some lawn maintenance using a steel blade on his weed-whacker. He fails to properly tighten the blade and it comes loose while he is trimming some tall grass at the edge of his property. The blade flies off towards his neighbor's house and crashes into the HVAC unit, severing the lines and effectively destroying the unit. Which coverage in John's homeowners policy might pay for the damage he caused to his neighbor's HVAC system? 
 
A. Coverage E - Personal Liability 
B. Coverage...
-
COSC 325 Houston (plumbing) sample questions and solutions |latest updates | GRADED A+
- Exam (elaborations) • 6 pages • 2024
-
- $8.99
- + learn more
COSC 325 Houston (plumbing) sample questions and 
solutions |latest updates | GRADED A+ 
SS - ANSWER Sanitary Sewer 
ABS - ANSWER Black plastic material 
VTR - ANSWER vent through roof 
Primary Purpose of roof vent - ANSWER Let air into system 
What division is plumbing - ANSWER 22 
Invert Depth - ANSWER elevation of the bottom inside of the pipe 
DW - ANSWER Domestic Water 
CPVC (chlorinated polyvinyl chloride) - ANSWER hot and cold water supply, off white color 
FDC - ANSWER Fire Dep...
-
ADJUSTER PRO PRACTICE EXAM TEST DUE ON 2023-2024
- Exam (elaborations) • 49 pages • 2023
- Available in package deal
-
- $17.99
- + learn more
ADJUSTER PRO PRACTICE EXAM TEST 
DUE ON 2023-2024 
John is doing some lawn maintenance using a steel blade on his weed-whacker. He 
fails to properly tighten the blade and it comes loose while he is trimming some tall 
grass at the edge of his property. The blade flies off towards his neighbor's house and 
crashes into the HVAC unit, severing the lines and effectively destroying the unit. Which 
coverage in John's homeowners policy might pay for the damage he caused to his 
neighbor's H...
-
Refrigeration And Air Conditioning Technology 8th Edition Tomczyk - Test Bank
- Exam (elaborations) • 199 pages • 2023
-
- $25.94
- + learn more
1. The component used to switch the heat pump unit between the heating and cooling modes of operation is the ____. 
 	a. 	four-way valve	b. 	bi-valve 
 	c. 	two-way valve	d. 	switching valve 
ANSWER: 	a 
POINTS: 	1 
REFERENCES: 	Reverse-Cycle Refrigeration 
QUESTION TYPE: 	Multiple Choice 
HAS VARIABLES: 	False 
DATE CREATED: 	3/12/2015 12:23 PM 
DATE MODIFIED: 	12/19/2015 6:31 PM 
 
 
2. An air-to-air heat pump ____ heat from the outside air and deposits it in the conditioned space. 
 	a...
-
NATE Final Exam #2, question and answers with rated solutions
- Exam (elaborations) • 23 pages • 2023
-
Available in package deal
-
- $18.49
- + learn more
NATE Final Exam #2, question and answers with rated solutions 
A condensing unit should be mounted on a slab that is level to: 
 
A: Allow any accumulated water to evenly run out of the cabinet 
 
B: Increase airflow through the fin area 
 
C: Prevent the unit from tipping over 
 
D: Make certain any top discharge air blows straight up 
A 
 
 
 
A simple time-activated switch is an example of a control that does not use: 
 
A: Feedback 
 
B: Electronics 
 
C: Calibration 
 
D: Manual adjustment ...