Hvac r 410a - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Hvac r 410a? On this page you'll find 40 study documents about Hvac r 410a.
Page 2 out of 40 results
Sort by
-
HVAC EXCELLENCE EXAM QUESTIONS AND ANSWERS 100% PASS
- Exam (elaborations) • 10 pages • 2024
-
- $12.49
- + learn more
HVAC EXCELLENCE EXAM QUESTIONS 
AND ANSWERS 100% PASS 
Heat which causes a change in temperature of a substance is called - Correct Answer ️️ 
-sensible heat, 
Heat added to a substance without a rise in temperature; (example: liquid refrigerant to 
gas) this process la called? - Correct Answer ️️ -latent heat 
Heat added to the refrigerant in vapor state after the evaporation process is called, - 
Correct Answer ️️ -superheat 
A scroll compressor moves refrigerant by means of; - Cor...
-
HVAC Excellence Study Guide With Accurate Solutions.
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
HVAC Excellence Study Guide With 
Accurate Solutions. 
Heat which causes a change in temperature of a substance is called. - answersensible heat. 
Heat added to a substance without a rise in temperature; (example: liquid refrigerant to gas) this 
process is called? - answerLatent heat 
Heat added to the refrigerant in a vapor state after the evaporator process is called. - 
answerSuperheat 
A scroll compressor moves refrigerant by means of. - answerInvolute spirals 
The movement of heat by way o...
-
HVAC CONTRACTOR EXAM COMPLETE SOLUTIONS
- Exam (elaborations) • 23 pages • 2024
-
Available in package deal
-
- $9.49
- + learn more
HVAC CONTRACTOR EXAM COMPLETE SOLUTIONS 
An instrument that measures potential differences between 2 points in an electrical circuit is called? 
A. potentiometer 
B. thermistor 
C. ohmeter 
D. voltmeter ️voltmeter 
This device uses a thermal sensing bulb at the outlet of the evaporator to sense temperature and 
control superheat 
A. automatic expansion valve 
B. thermostatic expansion valve 
C. low side float 
D. schraeder valve ️thermostatic expansion valve 
when installing a re...
-
HVAC Air Condition Esco 2024 Questions And Answers Latest Top Score.
- Exam (elaborations) • 7 pages • 2024
-
- $13.99
- + learn more
HVAC Air Condition Esco 2024 Questions And Answers Latest Top Score. 
 
 
 
 
 
Heat which causes a change in temperature of a substance is called - correct answer. Sensible Heat 
 
Heat added to a substance without a rise in temperature is called - correct answer. Latent Heat 
 
Heat added to refrigerant in a vapor state after the evaporation process is called - correct answer. Superheat 
 
A scroll compressor moved refrigerant by means of - correct answer. Involute spirals 
 
The m...
-
HVAC Final Quizlet 1, HVAC Final Questions & Answers!
- Exam (elaborations) • 4 pages • 2024
- Available in package deal
-
- $15.49
- + learn more
Evaporator Coil - ANSWER What component of an air conditioning system absorbs heat into the refrigerant 
 
Ventilation - ANSWER What does the V stand for in HVAC? 
 
Hot Surface Ignition - ANSWER What type of ignition is utilized by the furnaces in the shop? 
 
Air Conditioning - ANSWER What is the term for Refrigeration applied to the space temperature of a building? 
 
Electricity, L.P., Natural Gas - ANSWER What are the three fuels used in package heating units? 
 
Roof Top - ANSWER What is t...
As you read this, a fellow student has made another $4.70
-
EPA 608 Type 2 Practice exam with 100% correct answers
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $14.99
- + learn more
B 
retrofitted or retired within 12 months. 
If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be; 
A retrofitted or retired within 3 months. 
B retrofitted or retired within 12 months. 
C replaced within 3 months. 
D replaced within 12 months. 
 
 
 
B 10 inches of vacuum 
A high-pressure appliance containing 210 lbs. of R-407C refrigerant must be evacuated (recovered) to a level of; 
A 15 inches of vacuum 
B 10 inches of vacuum 
C 4 inches of vacuum 
D 0 ...
-
NATE Exam: Air Conditioning and Heat Pump Questions with Correct Solutions
- Exam (elaborations) • 14 pages • 2023
-
Available in package deal
-
- $9.99
- + learn more
a (Centrifugal) - Which of the following compressors are considered a dynamic compressor? 
 
a. Centrifugal 
b. Reciprocating 
d. Rotary 
c. Scroll 
 
b (Superheated vapor / sub cooled liquid) - What is the condition of the refrigerant as it enters and leaves the condensing coil of a typical light commercial HVAC system? 
 
a. Vapor / liquid 
b. Superheated vapor / sub cooled liquid 
c. Saturated vapor / saturated liquid 
d. Hot gas / cool liquid 
 
b (Thermal expansion valve) - Which o...
-
LEED AP O&M Practice Test questions and answers 2022/2023 with complete solution
- Exam (elaborations) • 34 pages • 2023
-
- $13.49
- + learn more
LEED AP O&M Practice Test questions and answers 2022/2023 with complete solution 
 
A project team is assessing existing luminaires for Light Pollution Reduction and found some fixtures emit light at a vertical angle more than 90 degrees from straight down. What statement is true regarding the project's ability to earn the credit? 
The team must retrofit or replace the non-compliant fixtures to earn the credit 
An office building has six individual workstations, two private offices, and a confe...
-
EPA 608 Type 2 Practice actual exam 2024 with 100% correct answers(download to pass)
- Exam (elaborations) • 3 pages • 2024
- Available in package deal
-
- $14.99
- + learn more
If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be; 
A retrofitted or retired within 3 months. 
B retrofitted or retired within 12 months. 
C replaced within 3 months. 
D replaced within 12 months. 
B 
retrofitted or retired within 12 months. 
 
 
 
A high-pressure appliance containing 210 lbs. of R-407C refrigerant must be evacuated (recovered) to a level of; 
A 15 inches of vacuum 
B 10 inches of vacuum 
C 4 inches of vacuum 
D 0 inches of vacuum 
B 10 ...
-
HVAC EXCELLENCE ALREADY GRADED A
- Exam (elaborations) • 9 pages • 2024
-
Available in package deal
-
- $9.99
- + learn more
HVAC EXCELLENCE ALREADY GRADED A 
Heat which causes a change in temperature of a substance is called ️sensible heat, 
Heat added to a substance without a rise in temperature; (example: liquid refrigerant to gas) this 
process la called? ️latent heat 
Heat added to the refrigerant in vapor state after the evaporation process is called, ️superheat 
A scroll compressor moves refrigerant by means of; ️involute spirals 
The movement of heat by way of fluid or is called; air ️convectio...
How did he do that? By selling his study resources on Stuvia. Try it yourself! Discover all about earning on Stuvia