ACI Concrete Field Testing Technician - Grade I Exam Questions and Answers
  • ACI Concrete Field Testing Technician - Grade I Exam Questions and Answers

  • Exam (elaborations) • 6 pages • 2024
  • Available in package deal
  • ACI Concrete Field Testing Technician - Grade I Exam Questions and Answers The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - Answer- 77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - Answer- 0.5 C / +-1F / 0-50 Decrees C The temp. measuring device shall be verified __,...
    (0)
  • $11.49
  • + learn more
ACI Concrete Field Testing Technician  Grade I Practice Exam Questions and  Answers 100% Verified
  • ACI Concrete Field Testing Technician Grade I Practice Exam Questions and Answers 100% Verified

  • Exam (elaborations) • 5 pages • 2024
  • ACI Concrete Field Testing Technician Grade I Practice Exam Questions and Answers 100% Verified The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - CORRECT ANSWER-77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - CORRECT ANSWER-0.5 C / +-1F / 0-50 Decrees C The tem...
    (0)
  • $11.99
  • + learn more
ACI Concrete Field Testing Technician - Grade I License Exam With Correct Answers 2024.
  • ACI Concrete Field Testing Technician - Grade I License Exam With Correct Answers 2024.

  • Exam (elaborations) • 6 pages • 2024
  • The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - Answer 77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - Answer 0.5 C / +-1F / 0-50 Decrees C The temp. measuring device shall be verified __, or whenever there is a question of __. - Answer Annually / accuracy T...
    (0)
  • $8.09
  • + learn more
ACI Concrete Field Testing Technician - Grade I Exam with Guaranteed Accurate Answers
  • ACI Concrete Field Testing Technician - Grade I Exam with Guaranteed Accurate Answers

  • Exam (elaborations) • 7 pages • 2024
  • The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - correct answer 77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - correct answer 0.5 C / +-1F / 0-50 Decrees C The temp. measuring device shall be verified __, or whenever there is a question of __. - correct answer Annual...
    (0)
  • $8.29
  • + learn more
ACI Concrete Field Testing Technician - Grade I Test | Questions and Verified Solutions | Latest Update 2024/2025
  • ACI Concrete Field Testing Technician - Grade I Test | Questions and Verified Solutions | Latest Update 2024/2025

  • Exam (elaborations) • 7 pages • 2024
  • Available in package deal
  • ACI Concrete Field Testing Technician - Grade I Test | Questions and Verified Solutions | Latest Update 2024/2025 The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - Answer -77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - Answer -0.5 C / +-1F / 0-50 Decrees C The tem...
    (0)
  • $11.99
  • + learn more
ACI Concrete Field Testing Technician - Grade I Questions with Correct Answers
  • ACI Concrete Field Testing Technician - Grade I Questions with Correct Answers

  • Exam (elaborations) • 5 pages • 2024
  • Available in package deal
  • The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. Correct Answer 77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. Correct Answer 0.5 C / +-1F / 0-50 Decrees C The temp. measuring device shall be verified __, or whenever there is a question of __. Correct Answer Annually / a...
    (0)
  • $12.99
  • + learn more
ACI Concrete Field Testing Technician - Grade I Exam Questions and Answers
  • ACI Concrete Field Testing Technician - Grade I Exam Questions and Answers

  • Exam (elaborations) • 6 pages • 2024
  • Available in package deal
  • ACI Concrete Field Testing Technician - Grade I Exam Questions and Answers The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - Answer- 77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - Answer- 0.5 C / +-1F / 0-50 Decrees C The temp. measuring device shall be verified __,...
    (0)
  • $12.49
  • + learn more
ACI Concrete Field Testing Technician - Grade I Test | Questions and Verified Solutions | Latest Update 2024/2025
  • ACI Concrete Field Testing Technician - Grade I Test | Questions and Verified Solutions | Latest Update 2024/2025

  • Exam (elaborations) • 7 pages • 2024
  • Available in package deal
  • ACI Concrete Field Testing Technician - Grade I Test | Questions and Verified Solutions | Latest Update 2024/2025 The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - Answer -77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - Answer -0.5 C / +-1F / 0-50 Decrees C The tem...
    (0)
  • $11.99
  • + learn more
ACI Concrete Field Testing Technician  Grade I Practice Exam Questions and  Answers 100% Verified
  • ACI Concrete Field Testing Technician Grade I Practice Exam Questions and Answers 100% Verified

  • Exam (elaborations) • 5 pages • 2024
  • Available in package deal
  • The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - CORRECT ANSWER-77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - CORRECT ANSWER-0.5 C / +-1F / 0-50 Decrees C The temp. measuring device shall be verified __, or whenever there is a question of __. - CORRECT ANSWER-A...
    (0)
  • $7.99
  • + learn more
ACI Concrete Field Testing Technician - Grade I | Questions and Correct Solutions | Latest Update 2024/2025
  • ACI Concrete Field Testing Technician - Grade I | Questions and Correct Solutions | Latest Update 2024/2025

  • Exam (elaborations) • 7 pages • 2024
  • Available in package deal
  • ACI Concrete Field Testing Technician - Grade I | Questions and Correct Solutions | Latest Update 2024/2025 The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - Answer -77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - Answer -0.5 C / +-1F / 0-50 Decrees C The temp. mea...
    (0)
  • $11.49
  • + learn more