EPA 608 Type 3 Exam Questions And Answers
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $10.99
- + learn more
EPA 608 Type 3 Exam Questions And Answers 
 
 
On low pressure chillers, moisture typically enters the refrigerant system through - ANS air leaks from areas with gaskets or fittings 
 
The maximum test pressure for leak testing a low pressure centrifugal is: - ANS 10 psig 
 
Leak test and repair the chiller to reduce refrigerant loss from a purge unit on CFC-11 chiller - ANS ... 
 
A hydrostatic tube test kit is used to: - ANS determine if a tube leaks 
 
Commercial and industrial proce...
-
EPA 608 Type 3 Updated 2024/2025 Verified 100%
- Exam (elaborations) • 13 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
The primary water source for cooling the condenser of a water-cooled recovery unit is: - local 
municipal water supply 
Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - replacement 
of evaporator coil 
According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above 
____ during a standing vacuum test, the system should be checked for leaks. - 2.5 mm Hg 
On low pressure chillers, moisture typically enters the refrigerant syst...
-
EPA 608 CORE EXAM TESTS COMBINED | VERIFIED TEST QUESTIONS WITH CORRECT SOLUTIONS
- Exam (elaborations) • 102 pages • 2023
- Available in package deal
-
- $15.99
- + learn more
EPA 608 CORE EXAM TESTS 
COMBINED | VERIFIED TEST 
QUESTIONS WITH CORRECT 
SOLUTIONS 
Where is the stratosphere? - ANSWER 10 to 30 miles 
Where is ozone located? - ANSWER stratosphere 
What does ozone in the stratosphere above the earth consist of? 
a. Molecules containing 2 oxygen atoms 
b. Molecules containing 3 oxygen atoms 
c. Molecules containing 4 oxygen atoms 
d. Molecules containing 5 oxygen atoms - ANSWER b. Molecules 
containing 3 oxygen atoms 
Which of the following refrigerants ha...
-
EPA 609 EXAM 2024 WITH 100% CORRECT ANSWERS
- Exam (elaborations) • 6 pages • 2024
-
- $16.99
- + learn more
Lifetime of CFCs is believed to range from _____ years? - correct answer 2 to 100 
 
For determining the Ozone Depletion Potential ________ having been assigned a factor of 1? - correct answer CFC-11 
 
Ester-based synthetic oils can be mixed with other oils? - correct answer False 
 
Since ________, it is no longer legal for CFCs to be manufactured or imported into the United States? - correct answer January 1, 1996 
 
Since _____, it is illegal to vent substitutes for CFC and HCFC refriger...
-
EPA 608 Type 3 exam with 100% Complete Solutions Lates 2024-2025 (Graded A+)
- Exam (elaborations) • 16 pages • 2024
-
Available in package deal
-
- $12.49
- + learn more
EPA 608 Type 3 exam with 100% Complete Solutions Lates (Graded A+) On low pressure chillers, moisture typically enters the refrigerant system through 
air leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal is: 
10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on 
CFC-11 chiller 
... 
A hydrostatic tube test kit is used to: 
determine if a tube leaks 
Commercial and industrial process refrigeratio...
Fear of missing out? Then don’t!
-
EPA 608 Type 3 exam with 100% Complete Solutions Latest 2024/2025 (Graded A+)
- Exam (elaborations) • 16 pages • 2024
- Available in package deal
-
- $12.99
- + learn more
EPA 608 Type 3 exam with 100% Complete Solutions Latest 2024/2025 (Graded A+) On low pressure chillers, moisture typically enters the refrigerant system through 
air leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal is: 
10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on 
CFC-11 chiller 
... 
A hydrostatic tube test kit is used to: 
determine if a tube leaks 
Commercial and industrial process re...
-
EPA 608 Core Test Updated Sample Questions with Correct Answers 100% A+ Graded
- Exam (elaborations) • 51 pages • 2024
-
Available in package deal
-
- $18.99
- + learn more
EPA 608 Core Test Updated Sample Questions with Correct Answers 100% A+ Graded 
 
As of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 - CORRECT ANSWER-a. July 1, 1992 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the atmosphere that filters UV. 
b. Protective shield for Earth from the sun's harmful ultraviolent (UV) 
rays ...
-
EPA 609 Questions and Correct Answers & Latest Updated
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $10.49
- + learn more
Lifetime of CFCs is believed to range from _____ years? 
o :## 2 to 100 
For determining the Ozone Depletion Potential ________ having been assigned a factor of 
1? 
o :## CFC-11 
Ester-based synthetic oils can be mixed with other oils? 
o :## False 
Since ________, it is no longer legal for CFCs to be manufactured or imported into the 
United States? 
o :## January 1, 1996 
Since _____, it is illegal to vent substitutes for CFC and HCFC refrigerants? 
o :## November 15, 1995 
Ozone at ground ...
-
EPA 609 Questions and Answers Already Passed
- Exam (elaborations) • 10 pages • 2023
-
Available in package deal
-
- $9.99
- + learn more
EPA 609 Questions and Answers Already Passed Lifetime of CFCs is believed to range from _____ years? 2 to 100 
For determining the Ozone Depletion Potential ________ having been assigned a factor of 1? CFC-11 
Ester-based synthetic oils can be mixed with other oils? False 
Since ________, it is no longer legal for CFCs to be manufactured or imported into the United States? January 1, 1996 
Since _____, it is illegal to vent substitutes for CFC and HCFC refrigerants? November 15, 1995 
Ozone at g...
-
EPA Core Practice Test, Type I, and Type II Questions & Answers 2023
- Exam (elaborations) • 14 pages • 2023
-
Available in package deal
-
- $8.00
- + learn more
As of what date did it become unlawful to release Class 1 and Class II refrigerants 
to the atmosphere? - July 1, 1992 
What is the ozone layer and why is it important to us on Earth? - Protective shield 
for Earth from the sun's harmful ultraviolet. 
The atom found in CFC and HCFC refrigerants that destroys ozone in the 
atmosphere is? - Chlorine 
What is an ozone molecule made of? - Three oxygen atoms (O3) 
Which refrigerant is a CFC? - R-12 
What is the name of the atom that attacks ozone...
Do you wonder why so many students wear nice clothes, have money to spare and enjoy tons of free time? Well, they sell on Stuvia! Imagine your study notes being downloaded a dozen times for $15 each. Every. Single. Day. Discover all about earning on Stuvia