Texas Commission on Fire Protection (TCFP) Driver/ Operator Test Questions and Answers 2024/2025 | 100% Verified.
- Exam (elaborations) • 35 pages • 2024
- Available in package deal
-
- $17.99
- + learn more
Texas Commission on Fire Protection (TCFP) Driver/ Operator Test Questions and Answers 2024/2025 | 100% Verified. In 1720 what was the piece of equipment to replace the bucket brigade? 
Hand Pump 
Which NFPA standard required new fire apparatus to be designed so that all members riding on the fire 
apparatus would be provided a seated area inside an enclosed cab? 
NFPA 1500 
What was the first gasoline powered fire apparatus to discharge water by using a large soda acid 
extinguisher? 
Chemical ...
-
TCFP Driver/ Operator Questions Bank | 600 Questions and Answers | Latest Update 2024.
- Exam (elaborations) • 93 pages • 2024
-
- $15.49
- + learn more
TCFP Driver/ Operator Questions Bank | 600 Questions and Answers | Latest Update 2024. 
In 1720 what was the piece of equipment to replace the bucket brigade? 
Hand Pump 
Which NFPA standard required new fire apparatus to be designed so that all members riding on the fire 
apparatus would be provided a seated area inside an enclosed cab? 
NFPA 1500 
What was the first gasoline powered fire apparatus to discharge water by using a large soda acid 
extinguisher? 
Chemical Wagon 
The real breakthrou...
-
Texas Commission on Fire Protection (TCFP) Driver/ Operator Test Questions and Answers 2024/2025
- Exam (elaborations) • 35 pages • 2024
-
Available in package deal
-
- $17.49
- + learn more
Texas Commission on Fire Protection (TCFP) Driver/ Operator Test Questions and Answers 2024/2025. In 1720 what was the piece of equipment to replace the bucket brigade? 
Hand Pump 
Which NFPA standard required new fire apparatus to be designed so that all members riding on the fire 
apparatus would be provided a seated area inside an enclosed cab? 
NFPA 1500 
What was the first gasoline powered fire apparatus to discharge water by using a large soda acid 
extinguisher? 
Chemical Wagon 
The real ...
-
Pumping Apparatus Driver/ Operator Final Exam Practice |Questions and Verified Answers| 2023/ 2024 Update
- Exam (elaborations) • 32 pages • 2023
-
Available in package deal
-
- $10.99
- + learn more
Pumping Apparatus Driver/ Operator Final Exam Practice |Questions and Verified Answers| 2023/ 2024 Update 
Q: NFPA 1901 specifies that the minimum pump capacity for pump design is: 
 
A. 250 GPM 
B. 500 GPM 
C. 750 GPM 
D. 1000 GPM 
 
 
Answer: 
C 
 
 
 
Q: Apparatus service tests are conducted at least: 
 
A. Annually 
B. Quarterly 
C. Semi-Annually 
D. As often as local operating procedures dictate. 
 
 
Answer: 
C 
 
 
 
Q: The items that the driver/operator is responsible for should be dicta...
-
Fire Apparatus Operator. Pumper Questions with Accurate Answers
- Exam (elaborations) • 12 pages • 2024
-
Available in package deal
-
- $13.99
- + learn more
Fire Apparatus Operator. Pumper Questions with Accurate Answers 
Becoming a good pump operator requires 
constant learning and training. 
 
 
 
In reality, ___ _____ and _____ prevail in both fire suppression and pump operations 
scientific theory principles 
 
 
 
 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 seconds 
Unmute 
0:08 
/ 
0:15 
Full screen 
Brainpower 
Read More 
The role of the _____ is a noble position in the fire service 
fire pump operator 
 
 
 
Ever-increasing re...
Want to regain your expenses?
-
Pumper-Operator Questions and Answers Graded A+
- Exam (elaborations) • 23 pages • 2024
-
Available in package deal
-
- $17.49
- + learn more
Pumper-Operator Questions and Answers Graded A+ 
When was the first hand pump invented 
1720, by Richard Newsham 
 
 
 
Where was the first wooden water mains for firefighting 
Philadelphia, early 1800s 
 
 
 
What were the first mechanized fire pumps fueled by 
Coal 
 
 
 
When was the first gas powered apparatus 
1900 
 
 
 
When was triple combination pumper created 
1906 
 
 
 
Apparatus safety standards 
NFPA 1901 -standards for fire apparatus 
NFPA 1500 - health safety for firefighters 
 
...
-
TCFP Driver/ Operator Questions Bank | 600 Questions and Answers | Latest Update 2024.
- Exam (elaborations) • 93 pages • 2024
-
- $14.99
- + learn more
TCFP Driver/ Operator Questions Bank | 600 Questions and Answers | Latest Update 2024. 
In 1720 what was the piece of equipment to replace the bucket brigade? 
Hand Pump 
Which NFPA standard required new fire apparatus to be designed so that all members riding on the fire 
apparatus would be provided a seated area inside an enclosed cab? 
NFPA 1500 
What was the first gasoline powered fire apparatus to discharge water by using a large soda acid 
extinguisher? 
Chemical Wagon 
The real breakthrou...
-
Pumping Apparatus Questions with Accurate Answers
- Exam (elaborations) • 43 pages • 2024
-
Available in package deal
-
- $15.99
- + learn more
Pumping Apparatus Questions with Accurate Answers 
What is the formula for the customary discharge rate? 
A. GPM= 29.7 x d2 x √NP 
B. GPM= 1.57 x NP x D2 
C. GPM= 29.7 x √D x NP2 
D. GPM= √29.7 x d2 x NP 
A 
 
 
 
Which NFPA standard gives direction for establishing a driving training program. 
A. 1450 
B. 1451 
C. 1560 
D. 1561 
A 
 
 
 
In general, to what vehicular statutes, laws and ordinances is the driver subject 
A. Only those concerning fire service driver/operators 
B. Only those ...
-
Pumping Apparatus Driver/ Operator Exam |Complete Guide with Questions and Verified Answers| 2023/ 2024 Newly Updated
- Exam (elaborations) • 95 pages • 2023
-
Available in package deal
-
- $11.49
- + learn more
Pumping Apparatus Driver/ Operator Exam |Complete Guide with Questions and Verified Answers| 2023/ 2024 Newly Updated 
Q: what should you do after drafting from a static water supply? 
 
 
Answer: 
flush the pump 
 
 
 
Q: how many firefighters were killed responding to or returning from emergency incidents in 2010? 
 
 
Answer: 
17 
 
 
 
Q: _______________ applies the brakes independently to aim the vehicle in the direction that the operator positions the steering wheel 
 
 
Answer: 
electroni...
-
FAE (ILLINOIS) questions and Answers Latest Update Fully Solved 100%
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
Two 2-1/2 inch supply lines, each 100 feet long with a total flow of 1000 gym, go to a siamese to 100 feet 
of 3 inch hose. What is the friction loss for this hose lay? 
a) 119 psi 
b) 129 psi 
c) 139 psi 
d) 149 psi - d) 149 psi 
The weight of air creates a pressure known as: 
a) Atmospheric pressure 
b) Gauge pressure 
c) Control pressure 
d) Hydraulic pressure - a) atmospheric pressure 
What is the total work done by the pump to get water into, through and out of the pump? 
a) Static Pressure...