On low pressure chillers, moisture typically enters the refrigerant system through *Ans* air 
leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal is: *Ans* 10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller 
*Ans* ... 
A hydrostatic tube test kit is used to: *Ans* determine if a tube leaks 
Commercial and industrial p...
![EPA 608 Complete BUNDLED Exams with 100% Correct Solutions 2024 | 2025](/docpics/5119998/662c8e89d4273_5119998_121_171.jpeg)
-
EPA 608 Complete BUNDLED Exams with 100% Correct Solutions 2024 | 2025
- Package deal • 7 items • 2024
-
AdelineJean
-
- $25.99
- + learn more
EPA 608 Complete BUNDLED Exams with 100% Correct Solutions 2024 | 2025. Refrigeration test, core test samples, certification study, core type 1, 2, 3, universal exam
![EPA 608 Type 31 ACTUAL EXAM COMPLETE QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ Practice questions for this set Terms in this set (139) On low pressure chillers, moisture typically enters the refrigerant system through	air leaks](/docpics/7143577/679d370a6ee8c_7143577_121_171.jpeg)
-
EPA 608 Type 31 ACTUAL EXAM COMPLETE QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ Practice questions for this set Terms in this set (139) On low pressure chillers, moisture typically enters the refrigerant system through	air leaks
- Exam (elaborations) • 13 pages • 2025
- Available in package deal
-
ProfessorJaneM
-
- $13.99
- + learn more
EPA 608 Type 31 ACTUAL EXAM COMPLETE QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ 
 
Practice questions for this set 
 
Terms in this set (139) 
On low pressure chillers, moisture typically enters the refrigerant system through	air leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal is:	10 psig 
A hydrostatic tube test kit is used to:	determine if a tube leaks 
A rupture disc on a recovery vessel for a low pressu...
![EPA 608 TYPE 3 TEST/ EPA 608 TYPE 3 REAL EXAM TEST 2024 LATEST UPDATE VERIFIED QUESTIONS & CORRECTLY HIGHLIGHTED ANSWERS 100% GUARANTEED PASS.](/docpics/4536802/65d270cbcb32f_4536802_121_171.jpeg)
-
EPA 608 TYPE 3 TEST/ EPA 608 TYPE 3 REAL EXAM TEST 2024 LATEST UPDATE VERIFIED QUESTIONS & CORRECTLY HIGHLIGHTED ANSWERS 100% GUARANTEED PASS.
- Exam (elaborations) • 27 pages • 2024
-
Available in package deal
-
Zencastiel
-
- $24.99
- + learn more
EPA 608 TYPE 3 TEST/ EPA 608 TYPE 3 REAL EXAM TEST 2024 
LATEST UPDATE VERIFIED QUESTIONS & CORRECTLY HIGHLIGHTED 
ANSWERS 100% GUARANTEED PASS. 
During the evacuation of a system containing large amounts of moisture you can 
prevent freezing of this moisture by increasing the pressure with______gas - 
ANSWER- nitrogen 
ASHRAE standard 15-1994 requires that each machinery room must activate an alarm 
and mechanical ventilation beofre refrigerant concentrations exceed: - ANSWER- the 
thresh...
![EPA 608 Type 3 exam | Questions and Correct Solutions | Graded A+](/docpics/6180164/66e2c761090e8_6180164_121_171.jpeg)
-
EPA 608 Type 3 exam | Questions and Correct Solutions | Graded A+
- Exam (elaborations) • 16 pages • 2024
- Available in package deal
-
mercylynneh
-
- $11.99
- + learn more
EPA 608 Type 3 exam | Questions 
and Correct Solutions | Graded A+ 
On low pressure chillers, moisture typically enters the refrigerant 
system through - Answer -air leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal 
is: - Answer -10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge 
unit on CFC-11 chiller - Answer -... 
A hydrostatic tube test kit is used to: - Answer -determine if a tube leaks 
Commerci...
![EPA 608 Type 3 exam with 100% Complete Solutions](/docpics/5555779/6661689d4446a_5555779_121_171.jpeg)
-
EPA 608 Type 3 exam with 100% Complete Solutions
- Exam (elaborations) • 16 pages • 2024
-
Available in package deal
-
STUDYROOM2024
-
- $13.49
- + learn more
EPA 608 Type 3 exam with 100% Complete Solutions. On low pressure chillers, moisture typically enters the refrigerant system through 
air leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal is: 
10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on 
CFC-11 chiller 
... 
A hydrostatic tube test kit is used to: 
determine if a tube leaks 
Commercial and industrial process refrigeration systems must be ...
![EPA 608 CORE EXAM QUESTIONS AND ANSWERS](/docpics/4521076/65cfd2fa7f553_4521076_121_171.jpeg)
-
EPA 608 CORE EXAM QUESTIONS AND ANSWERS
- Exam (elaborations) • 23 pages • 2024
- Available in package deal
-
EmilyCharlene
-
- $13.49
- + learn more
EPA 608 CORE EXAM QUESTIONS AND ANSWERS 
What characteristic or characteristics of CFCs make them more likely than other chlorine 
compounds to reach the stratosphere? - Answer ️️ -Dont disolve iin water 
Each chlorine atom in the stratosphere can destroy how many ozone molecules? - Answer ️️ - 
100,000 ozone molecules 
Which refrigerant contains a CFC? 
R500, R12, R113 or R11? - Answer ️️ -Theyre all CFC's 
HYDROCHLORIC FLORICCARBON (HCFC) refrigerant contain? - Answer ️️ -Hydr...
![EPA 608 (TYPE II) Exam Questions and Answers | Latest Version | 2024/2025 | Already Passed](/docpics/5897322/66a5550e8a6d7_5897322_121_171.jpeg)
-
EPA 608 (TYPE II) Exam Questions and Answers | Latest Version | 2024/2025 | Already Passed
- Exam (elaborations) • 12 pages • 2024
-
Available in package deal
-
SterlingScores
-
- $9.71
- + learn more
EPA 608 (TYPE II) Exam Questions and 
Answers | Latest Version | 2024/2025 | 
 
Already Passed 
 
When setting up a newly assembled system, what is the initial step? Introduce inert gas to 
pressurize the system and perform a leak test. 
 
According to EPA guidelines, appliances with refrigerant amounts exceeding 50 pounds 
(excluding those for commercial and industrial processes) must be fixed if the leakage rate 
surpasses what percentage of the total charge per year? 15% 
 
What is the minimu...
![EPA 608 Type 3 Exam Questions with 100% Correct Answers | Verified | Latest Update 2024| Rated A+](/docpics/4543370/65d375ab0b49b_4543370_121_171.jpeg)
-
EPA 608 Type 3 Exam Questions with 100% Correct Answers | Verified | Latest Update 2024| Rated A+
- Exam (elaborations) • 19 pages • 2024
-
Available in package deal
-
Scores
-
- $8.99
- + learn more
EPA 608 Type 3 Exam Questions with 100% Correct Answers | Verified | Latest Update 2024| Rated A+ 
On low pressure chillers, moisture typically enters the refrigerant system through air leaks from areas with gaskets or fittings 
The maximum test pressure for leak testing a low pressure centrifugal is: 10 psig 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller ... 
A hydrostatic tube test kit is used to: determine if a tube leaks 
Commercial and indus...
![EPA 608 Type III Sample Test Questions Exam Elaboration |Question and Answers| 100% Correct](/docpics/5501134/665a4d1b875b5_5501134_121_171.jpeg)
-
EPA 608 Type III Sample Test Questions Exam Elaboration |Question and Answers| 100% Correct
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
AceTests
-
- $9.99
- + learn more
EPA 608 Type III Sample Test Questions 
Exam Elaboration |Question and 
Answers| 100% Correct 
Where do leaks commonly occur in low pressure systems? 
a. Evaporator 
b. Condenser 
c. Purge unit 
d. Gaskets or fittings *Ans* d. Gaskets or fittings 
Where do leaks commonly occur in open-drive type compressor systems? 
a. Evaporator 
b. Condenser 
c. Shaft seal 
d. Cooling tower *Ans* c. Shaft seal 
Does refrigerant go out of the system in low pressure systems or does air and 
moisture go in? 
a. ...