What type of equipment can be worked on with Type III certification? low pressure 
The most efficient method of leak checking a charged low-pressure refrigeration unit is to 
pressurize the system by the use of controlled hot water or heater blankets 
When pressurizing a system, do not exceed 10 psig 
After reaching the required vacuum on an appliance when servicing, moisture is indicated by 
multiple ris...
-
EPA 608 TYPE II EXAM QUESTIONS WITH CORRECTRY ANALYZED ANSWERS (ACTUAL EXAM) ALREADY GRADED A+ LATEST 2024
- Exam (elaborations) • 38 pages • 2024
-
- $12.99
- + learn more
EPA 608 TYPE II EXAM QUESTIONS WITH CORRECTRY ANALYZED ANSWERS (ACTUAL EXAM) ALREADY GRADED A+ LATEST 2024
-
EPA Certification Exam Prep (2023/ 2024 Update) Practice Questions and Verified Answers| 100% Correct| Grade A
- Exam (elaborations) • 47 pages • 2023
-
Available in package deal
-
- $10.99
- + learn more
EPA Certification Exam Prep (2023/ 2024 Update) Practice Questions and Verified Answers| 100% Correct| Grade A 
 
Q: What are 6 Type II appliances? 
 
 
Answer: 
1.Walk-in coolers 
2.Walk-in freezers 
3.Reach-in refrigerators 
4.Reach-in freezers 
5.Residential & Commercial comfort cooling systems 
6.Ice machines 
 
 
Q: To justify the cost increases of service to a customer, simply explain that ----- and required ---- to recover refrigerants in order to ----- and -----. 
 
 
Answer: 
you are b...
-
EPA Type III Questions and Answers 100% Pass
- Exam (elaborations) • 3 pages • 2023
- Available in package deal
-
- $10.98
- + learn more
What type of equipment can be worked on with Type III certification? low pressure 
The most efficient method of leak checking a charged low-pressure refrigeration unit is to 
pressurize the system by the use of controlled hot water or heater blankets 
When pressurizing a system, do not exceed 10 psig 
After reaching the required vacuum on an appliance when servicing, moisture is indicated by 
multiple rises in pressure over a period of time with increase of pauses between rises 
EPA required eva...
Get paid weekly? You can!
-
EPA 608 (TYPE II) Type 2 Test Exam With correct Answers 2024 Questions and Answers 2024 / 2025 (Verified Answers by Expert)
- Exam (elaborations) • 14 pages • 2024
- Available in package deal
-
- $13.99
- + learn more
EPA 608 (TYPE II) Type 2 Test Exam With correct Answers 2024 Questions and Answers 2024 / 2025 (Verified Answers by Expert)
-
EPA Type III Questions and Answers 100% Pass
- Exam (elaborations) • 2 pages • 2024
-
- $8.49
- + learn more
EPA Type III Questions and Answers 100% Pass 
What type of equipment can be worked on with Type III certification? - Answer ️️ -low 
pressure 
The most efficient method of leak checking a charged low-pressure refrigeration unit is to - 
Answer ️️ -pressurize the system by the use of controlled hot water or heater blankets 
When pressurizing a system, do not exceed - Answer ️️ -10 psig 
After reaching the required vacuum on an appliance when servicing, moisture is indicated by - 
Answ...
-
Asbestos Contractor/Supervisor Examination | Actual questions and answers | updated
- Exam (elaborations) • 5 pages • 2023
- Available in package deal
-
- $9.99
- 1x sold
- + learn more
Asbestos Contractor/Supervisor Examination | Actual questions and answers | updated 
 
Fibers - Asbestos is a generic name for a group of minerals that form __________ 
Hood, booties, coveralls - The following are parts of a protective clothing ensemble 
Removal of 5 feet of pipe insulation in order to fix a leak in the pipe - Which of the following operations would be considered to be an OSHA Class II job? 
Holes cut in the polyethylene next to the machines - Make-up air for a negative ...
-
(Answered) EPA SECTION 608 CORE (2021-2022 revision)
- Exam (elaborations) • 20 pages • 2022
-
Available in package deal
-
- $9.99
- 2x sold
- + learn more
EPA SECTION 608 CORE (2021-2022 revision) 
A disposable cylinder should be reduced to what pressure before scrapping? 
a. 0 psig 
b. 20 psig 
c. 50 psig 
d. 80 psig 
 
A major system repair is being performed on a R-22 appliance. What CANNOT be done to recharge the appliance? 
a. Add R-22 after the repair is complete. 
b. Retrofit the unit to R-407C. 
c. Use recovered or recycled R-22 from the same 
owner. 
d. Top off the unit with R-410a. 
A refillable cylinder must not be filled above what ...
-
EPA SECTION 608 TYPE I, TYPE II , TYPE III Accurate 100%
- Exam (elaborations) • 63 pages • 2024
-
Available in package deal
-
- $14.99
- + learn more
EPA SECTION 608 TYPE I, TYPE II , TYPE III Acc 
What is typically used on small appliances as a service aperture or other device for adding or removing refrigerant? 
a. A straight piece of tubing that is entered using a piercing access tube. 
b. A line located 15 inches below the compressor. 
c. A valve installed at the factory which has a ¼ inch diameter and machine threads. 
d. A service aperture is not present because small appliances are exempt from this requirement. - ANSWER a. A straight ...