Image intensifier - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Image intensifier? On this page you'll find 264 study documents about Image intensifier.
Page 3 out of 264 results
Sort by
-
Fluoro questions with correct answers
- Exam (elaborations) • 15 pages • 2023
- Available in package deal
-
- $14.49
- + learn more
what are the factors that directly influence the exposure rate at the panel or tabletop and the patient and the operator's radiation dose? Answer milliamperage, kilovolatage, collimation, filtration, exposure time, target to panel (tabletop) distance (TPD), patient to image intensifier distance for over the table and under the table image intensifier systems, sensitivity of the image receptor 
 
what will reduce patient exposure? Answer 1.Collimation to the area of clinical interest only (requi...
-
ARRT prep exam 2 questions with correct answers
- Exam (elaborations) • 15 pages • 2023
- Available in package deal
-
- $14.99
- + learn more
Iron is an example of a _______________ material. CORRECT ANSWER Ferromagnetic 
 
For trauma radiography, a radiographer could best acquire images of a lateral distal femur by: CORRECT ANSWER acquiring a cross-table lateral femur with a lateromedial projection 
 
Total brightness gain for the image intensifier is calculated by: CORRECT ANSWER flux gain multiplied by minification gain. 
 
A person with acute radiation syndrome does not demonstrate signs of illness during the ________ 
period. COR...
-
ARRT REGISTRY IMAGE PRODUCTION questions and answers
- Exam (elaborations) • 39 pages • 2024
- Available in package deal
-
- $15.49
- + learn more
voltage is stepped up or stepped down by only a small amount and sent to the _______ side of the high voltage step up transformer 
primary 
 
 
 
where is the timer in the X-ray circuit? 
between autotransformer and high voltage transformer 
 
 
 
mAs timers are used with __________ generators 
falling load 
 
 
 
AEC 
fixed kVp, controlled mAs 
positioning must be perfect 
 
 
 
what is the shortest time with AEC? 
1 ms 
 
 
 
falling load generator 
RT sets mAs and kVp 
when max heat load of t...
-
Digital Fluoroscopy questions well answered rated A+ 2023
- Exam (elaborations) • 13 pages • 2023
- Available in package deal
-
- $11.49
- + learn more
Digital Fluoroscopy questions well answered rated A+ 2023Pixel size= - correct answer Image intensifier size/matrix 
 
Spatial resolution is determined/limited by - correct answer pixel size 
 
The larger the matrix, the more pixels 
pixel size would _______________________ - correct answer decrease (they are smaller) 
 
A larger matrix with smaller pixels increases _____________________ - correct answer spatial resolution 
 
Digital fluoroscopy (DF) is a digital x-ray imaging system that produc...
-
Mosby Exam Questions with Complete Solutions, A+
- Exam (elaborations) • 37 pages • 2024
-
Available in package deal
-
- $14.89
- + learn more
An injection set that includes a needle with plastic wings attached is called: 
 
A. large bore. 
 
B. butterfly. 
 
C. contrast agent injecting set. 
 
D. sterile tray. 
b 
X-rays travel as bundles of energy called: 
 
A. energy waves. 
 
B. phasers. 
 
C. electromagnetic bursts. 
 
D. photons. 
d 
The increase in brightness caused by acceleration of the electrons in the image intensifier is called: 
 
A. flux gain. 
 
B. minification gain. 
 
C. total brightness gain. 
 
D. image gain. 
a 
A p...
Get paid weekly? You can!
-
ARRT Kettering Questions And Answers With Complete Solutions
- Exam (elaborations) • 27 pages • 2023
-
Available in package deal
-
- $12.99
- + learn more
An image that demonstrates low contrast can be caused from: 
 1. High mAs 
2. Low kVp 
3. Insufficient beam restriction correct answer: 3 only 
 
Which of the following interactions with matter reduce contrast in an x-ray image? correct answer: Compton scattering 
 
From anatomical position, pronating the hand will result in the palm facing ____. correct answer: Posteriorly 
 
The maximum variation between consecutive exposures when using the same technical factor is: correct answer: withi...
-
C-Arm Operations with complete solutions
- Exam (elaborations) • 5 pages • 2024
-
- $14.99
- + learn more
What type of movement does the Horizontal Cross Arm do on the C-Arm machine? 
Extends c-arm a maximum of 8 inches out 
 
 
 
What type of movement does Wig Wag do on the C-Arm machine? 
moves c-arm from side to side 
 
 
 
What type of movement does the Vertical Column Lift do on the C-Arm machine? 
Raises and lowers the C-arm 
 
 
 
What type of movement does the Canting/Oblique Rotation do on the C-Arm machine? 
rotates the intensifier up to 115 degrees 
 
 
 
What type of movement does the La...
-
kettering mock Questions With Complete Solutions
- Exam (elaborations) • 26 pages • 2023
-
Available in package deal
-
- $12.99
- + learn more
An image that demonstrates low contrast can be caused from: 1. High mAs 2. Low kVp 3. Insufficient beam restriction correct answer: 3 only 
 
Which of the following interactions with matter reduce contrast in an x-ray image? correct answer: compton scattering 
 
What type of fracture is illustrated below? (femur bone sticking out of skin) correct answer: compound fx 
 
From anatomical position, pronating the hand will result in the palm facing ____ correct answer: posteriorly 
 
With all oth...
-
RCIS Practice Test Final Complete Exam Questions with Verified Answers 2024/2025
- Exam (elaborations) • 18 pages • 2024
-
- $14.99
- + learn more
RCIS Practice Test Final Complete Exam 
Questions with Verified Answers 
2024/2025 
What is the formula for calculating cardiac output? - CORRECT ANSWER-CO= HR x 
SV 
What is stroke volume related to? - CORRECT ANSWER-preload 
Preload is most impacted by..... - CORRECT ANSWER-Increased filling volumes 
A patient with chronic untreated hypertension would demonstrate.... - CORRECT 
ANSWER-Increased afterload 
Vascular resistance/pressure is most influenced by.... - CORRECT ANSWER-Radius of 
th...
-
Digital Fluoroscopy questions with correct answers
- Exam (elaborations) • 16 pages • 2023
- Available in package deal
-
- $15.99
- + learn more
Pixel size= Answer Image intensifier size/matrix 
 
Spatial resolution is determined/limited by Answer pixel size 
 
The larger the matrix, the more pixels 
pixel size would _______________________ Answer decrease (they are smaller) 
 
A larger matrix with smaller pixels increases _____________________ Answer spatial resolution 
 
Digital fluoroscopy (DF) is a digital x-ray imaging system that produces ________________ images obtained with an _________ x-ray beam. Answer dynamic 
area 
 
Th...
That summary you just bought made someone very happy. Also get paid weekly? Sell your study resources on Stuvia! Discover all about earning on Stuvia