Class 3 single-conductors shall NOT be smaller than _____. 
 
a) 18 AWG 
b) 16 AWG 
c) 14 AWG 
d) 20 AWG - Answer-A: 18 AWG 
Ref: 725.179(H) 
 
Given: an office building has a 208Y/120 volt, three-phase service with a balanced net computed load of 90 kVA. What is the current each ungrounded conductor carries at full load? 
 
a) 188 amperes 
b) 250 amperes 
c) 433 amperes 
d) 750 amperes - Answer-B: 250 amperes 
Ref: Trade an...
-
Journeyman Electrician Exam 1 - Q & A
- Exam (elaborations) • 6 pages • 2024
-
Available in package deal
-
- $10.49
- + learn more
Journeyman Electrician Exam 1 - Q & A When a pull box contains conductors of size 4 AWG and larger and a straight pull of the conductors is to be made, the length of the box shall NOT be less than _____ times the trade diameter of the largest conduit entering the box. a) six b) four c) eight d) twelve Ref: 314.28(A)(1) In general, all of the following wiring methods listed are permitted to be used as a feeder for temporary wiring on a construction site EXCEPT _____. a) NM cable b) NMC cable c)...
-
Journeyman electrician exam prep 2024
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman electrician exam prep 2024 
What table sizes bonding jumpers for for AC systems? -Answer-250.102(C)(1) 
The NEC defines continuous load to be a load where max current on the circuit 
continues for at least how many hours? -Answer-Three 
To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how 
many current carrying conductors in a raceway? -Answer-Greater than three 
Where in the NEC codebook would you find EMT sizes for a given size and number of 
conduc...
-
Journeyman Electrician #4 Exam Questions and Answers
- Exam (elaborations) • 11 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman Electrician #4 Exam 
Questions and Answers 
Where conduits enter a floor-standing switchboard or panelboard at the bottom, the 
conduits including their end fittings, shall not rise more than _____ above the bottom of 
the enclosure. 
a) 6 inches 
b) 4 inches 
c) 2 inches 
d) 3 inches -Answer-D: 3 inches 
Ref: 408.5 
When installed on the service of a building or structure, a type 2 SPD (TVSS) shall be 
connected _____. 
a)on the line side of the service disconnect overcurrent device ...
-
Journeyman Electrician Exam 4 - Q & A
- Exam (elaborations) • 6 pages • 2024
-
Available in package deal
-
- $10.49
- + learn more
Journeyman Electrician Exam 4 - Q & A When grounding the structural reinforcing steel of a swimming pool, what is the smallest size grounding conductor permitted for this installation? a) 12 AWG b) 10 AWG c) 8 AWG d) 6 AWG Ref: 680.26(B)(1)(a) and (b) A surge-protective device (SPD) is a protective device for _____. a) limiting transient voltage by diverting or limiting surge current b) limiting transient voltage by absorbing and storing excessive surge current c) switching transient voltage b...
As you read this, a fellow student has made another $4.70
-
Journeyman Electrician Exam Prep
- Exam (elaborations) • 13 pages • 2024
-
Available in package deal
-
- $9.99
- + learn more
Journeyman Electrician Exam Prep 
 
What table sizes bonding jumpers for for AC systems? - 250.102(C)(1) 
 
The NEC defines continuous load to be a load where max current on the circuit continues for at 
least how many hours? - Three 
 
To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how many 
current carrying conductors in a raceway? - Greater than three 
 
Where in the NEC codebook would you find EMT sizes for a given size and number of 
conductors? - Annex C...
-
Journeyman Electrician Exam 2024 (Grade A+)
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman Electrician Exam 2024 (Grade A+) 
Where K=12.9, what is the approximate voltage-drop on a circuit where an 80-ampere, 
240-volt, single-phase load is supplied with size 3 AWG copper conductors with THWN 
insulation, and placed 200 feet from a panelboard? 
*Chapter 9 tables, table 8 conductor properties 
(pg. 70-689) -Answer-7.84 volts 
voltage-drop formula 
VD=2KID VD=2 x 12.9 x 80amps x 200ft. =7.84 
CM 52.620 CM 
Given the following information, what is the maximum approximate dista...
-
Journeyman Electrician | Questions and Correct Answers | Latest Update 2024/2025
- Exam (elaborations) • 15 pages • 2024
-
- $11.99
- + learn more
Journeyman Electrician | 
Questions and Correct Answers | 
Latest Update 2024/2025 
For other than one-and two-family dwellings, when building a new 
electrical service, at least one (1) 125-volt, single-phase, 15- or 20- 
ampere-rated receptacle outlet shall be located within at LEAST _____ 
of the electrical service equipment? - Answer -50 feet 
The ampacity of a conductor is defined by the NEC to be the maximum 
current, in amperes, a conductor can carry continuously under the 
conditions of ...
-
Journeyman Electrician Exam 3
- Exam (elaborations) • 11 pages • 2024
-
Available in package deal
-
- $9.99
- + learn more
Journeyman Electrician Exam 3 
 
Where a water pipe passes over an indoor motor control center, leak protection apparatus shall 
have a MINIMUM clearance of _____. 
 
a) 6 feet to the protection apparatus 
b) 6 feet to the water pipe 
c) 6 1⁄2 feet to the protection apparatus 
d) 6 1⁄2 feet to the water pipe - A: 6 feet to the protection apparatus 
Ref: 110.26(F)(1)(a) 
 
Branch circuit grounded conductors that are not connected to an overcurrent device shall be 
permitted to be sized at LEA...
-
Journeyman Electrician 5 Exam Questions with Correct Answers
- Exam (elaborations) • 6 pages • 2024
-
Available in package deal
-
- $13.49
- + learn more
Journeyman Electrician 5 Exam Questions with Correct Answers 
 
 
Unless listed and identified otherwise, terminations and conductors of sizes 14 AWG through 1 AWG shall be rated at _____. 
 
a) 75°C 
b) 75°F 
c) 90°C 
d) 60°C - Answer-D: 60°C 
Ref: 110.14(C)(1)(a)(1) 
 
The MINIMUM size copper equipment bonding jumper on the supply side of a service consisting of parallel copper phase conductors with a total circular mil area of 2000 kcmil shall be ____. 
 
a) 2/0 AWG 
b) 3/0 AWG 
c) 4/0 ...