Journeyman Electrician Practice Exam #7 Questions and Answers
- Exam (elaborations) • 7 pages • 2024
-
Available in package deal
-
- $10.49
- + learn more
Journeyman Electrician Practice Exam #7 Questions and Answers
-
Journeyman Electrician Practice Exam Questions with Correct Answers
- Exam (elaborations) • 9 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Journeyman Electrician Practice Exam Questions with Correct Answers 
 
indicates open, single-conductors such as Type USE-2 and single-conductor cable listed and identified as PV wire are permitted foruse in PV source circuits within the PV array. 
 
These conductors are evaluated and listed for use where exposed to sunlight and wet conditions. 
 
For dwelling units, GFCI protection is required for all single-phase, 125-volt, 15- and 20-ampere receptacles installed within six (6) feet of the top...
-
Journeyman Electrician Practice Exam #7 Questions With Complete Solutions
- Exam (elaborations) • 11 pages • 2023
-
Available in package deal
-
- $10.99
- + learn more
Where the outer sheath of Type MI cable is made of steel _____________. 
 
A. it shall provide an adequate path to serve as an equipment grounding conductor 
 
B. a separate equipment grounding conductor shall be provided 
 
C. the grounding and grounded conductors shall be connected together 
 
D. it shall not be longer than 6 feet correct answer: B. a separate equipment grounding conductor shall be provided 
 
The interior of enclosures or raceways installed underground shall be considered to...
-
PSI - Journeyman Electrician Practice Exam Questions And Answers 100% Verified
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
PSI - Journeyman Electrician Practice Exam 
Questions And Answers 100% Verified 
An electrical appliance is rated at 1,500 watts, and is connected to 120 volts. What is the resistance 
associated with this appliance? - answer9.6 ohms 
What is the greatest root-mean-square (effective) difference of potential between any two conductors 
of a circuit defined as? - answerVoltage 
Approximately how many kilowatts are used by a three-phase, 480-volt ac motor that draws a current of 
52 amperes and has...
-
Journeyman Electrician Practice Exam with Complete Solutions 100% Verified
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
Journeyman Electrician Practice Exam 
with Complete Solutions 100% Verified 
What is the minimum size secondary conductor required for a 2 wire 480 volts/ 120 volts 
transformer rated at 2.3 KVA with 750C temperature at terminals? 
8 AWG 
10 AWG 
12 AWG 
14 AWG - answer14 AWG 
Secondary transformer current = 2300 / 120 = 19.16 amperes 
Refer: NEC Table 310.15(B)(16) 
The suitable conductor is 14 AWG with 20 amperes capacity at 750C 
What is the demand factor applied in calculating feeder or serv...
And that's how you make extra money
-
Journeyman Electrician Practice Exam With Complete Solutions
- Exam (elaborations) • 7 pages • 2024
-
- $11.99
- + learn more
Journeyman Electrician Practice Exam With Complete Solutions
-
PSI - Journeyman Electrician Practice Exam Questions And Answers 100% Verified
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
PSI - Journeyman Electrician Practice Exam 
Questions And Answers 100% Verified 
An electrical appliance is rated at 1,500 watts, and is connected to 120 volts. What is the resistance 
associated with this appliance? - answer9.6 ohms 
What is the greatest root-mean-square (effective) difference of potential between any two conductors 
of a circuit defined as? - answerVoltage 
Approximately how many kilowatts are used by a three-phase, 480-volt ac motor that draws a current of 
52 amperes and has...
-
Journeyman Electrician Practice Exam 7 Questions and Answers With Complete Solutions
- Exam (elaborations) • 9 pages • 2023
-
Available in package deal
-
- $10.49
- + learn more
Journeyman Electrician Practice Exam 7 Questions and Answers With Complete Solutions
-
Journeyman Electrician Practice Exam with Complete Solutions 100% Verified
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $10.49
- + learn more
Journeyman Electrician Practice Exam 
with Complete Solutions 100% Verified 
What is the minimum size secondary conductor required for a 2 wire 480 volts/ 120 volts 
transformer rated at 2.3 KVA with 750C temperature at terminals? 
8 AWG 
10 AWG 
12 AWG 
14 AWG - answer14 AWG 
Secondary transformer current = 2300 / 120 = 19.16 amperes 
Refer: NEC Table 310.15(B)(16) 
The suitable conductor is 14 AWG with 20 amperes capacity at 750C 
What is the demand factor applied in calculating feeder or serv...
-
Journeyman Electrician Practice Exam 7 questions and 100% correct answers 2024
- Exam (elaborations) • 10 pages • 2024
-
Available in package deal
-
- $14.99
- + learn more
Where the outer sheath of Type MI cable is made of steel _____________. 
 
A. it shall provide an adequate path to serve as an equipment grounding conductor 
 
B. a separate equipment grounding conductor shall be provided 
 
C. the grounding and grounded conductors shall be connected together 
 
D. it shall not be longer than 6 feet - correct answer B. a separate equipment grounding conductor shall be provided 
 
The interior of enclosures or raceways installed underground shall be considered to...