A home inspe Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about A home inspe? On this page you'll find 35 study documents about A home inspe.

All 35 results

Sort by

Florida Home Inspector Midterm Exam Fully Solved.
  • Florida Home Inspector Midterm Exam Fully Solved.

  • Exam (elaborations) • 121 pages • 2024
  • Service entrace conductors run from the service drop to the service box or service panel. True or False? - Answer True The service size is determined by the amperage and the voltage ratings of the service. - Answer True Is the service drop overhead or underground? - Answer Overhead Are service laterals overhead or underground? - Answer Underground The drip loop is typically part of the service drop. True or False? - Answer False The wire size for the service drop must be the ...
    (0)
  • $9.99
  • + learn more
Virginia Home Inspection Test exam 2023 with 100% correct answers
  • Virginia Home Inspection Test exam 2023 with 100% correct answers

  • Exam (elaborations) • 25 pages • 2023
  • What determines the amount of electricity (amperage) the wire can carry? - correct answer Size (diameter) How many wires are there from the street into the house in a 240 volt system? - correct answer 3 conductors The size of the fuses or breakers at the main disconnect will always tell you the how much electricity is available to the house? - correct answer FALSE What is the min. size wire to provide the house with 60 Amp. service? - correct answer #6 gauge (copper) How is the e...
    (0)
  • $17.49
  • + learn more
FLORIDA HOME INSPECTOR EXAM 1 questions with verified answers RATED A.
  • FLORIDA HOME INSPECTOR EXAM 1 questions with verified answers RATED A.

  • Exam (elaborations) • 19 pages • 2024
  • FLORIDA HOME INSPECTOR EXAM 1 questions with verified answers RATED A.FLORIDA HOME INSPECTOR EXAM 1 questions with verified answers RATED A.FLORIDA HOME INSPECTOR EXAM 1 questions with verified answers RATED A.FLORIDA HOME INSPECTOR EXAM 1 questions with verified answers RATED A.FLORIDA HOME INSPECTOR EXAM 1 questions with verified answers RATED A.FLORIDA HOME INSPECTOR EXAM 1 questions with verified answers RATED A.FLORIDA HOME INSPECTOR EXAM 1 questions with verified answers RATED A.FLORIDA HO...
    (0)
  • $17.99
  • + learn more
North Carolina Home Inspection Licensing Exam Study Guide With Correct Solutions.
  • North Carolina Home Inspection Licensing Exam Study Guide With Correct Solutions.

  • Exam (elaborations) • 22 pages • 2024
  • The ________ and _________ breaker panels are known to be major electrical fire hazards and have been recalled. - Answer FPE Stab-lok and Zinsco The service drop cable running over a 4:12 or greater pitch roof has to be ____ over the ridge. - Answer 3' If you have a 8 gauge stranded aluminum cable running to a 40 amp breaker that goes to an electric stove and a 10 gauge single strand copper cable running to a 40 amp breaker that goes to the condenser unit, which one is wrong and how w...
    (0)
  • $9.99
  • + learn more
Florida Home Inspector Exam with Guaranteed Accurate Answers
  • Florida Home Inspector Exam with Guaranteed Accurate Answers

  • Exam (elaborations) • 123 pages • 2024
  • Service entrace conductors run from the service drop to the service box or service panel. True or False? - correct answer True The service size is determined by the amperage and the voltage ratings of the service. - correct answer True Is the service drop overhead or underground? - correct answer Overhead Are service laterals overhead or underground? - correct answer Underground The drip loop is typically part of the service drop. True or False? - correct answer False The wire siz...
    (0)
  • $16.69
  • + learn more
FLORIDA HOME INSPECTOR EXAMBANK  (Questions +Answers) with correct and complete solutions|100% VERIFIED.
  • FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solutions|100% VERIFIED.

  • Exam (elaborations) • 88 pages • 2024
  • FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solutions|100% VERIFIED.FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solutions|100% VERIFIED.FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solutions|100% VERIFIED.FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solutions|100% VERIFIED.FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solu...
    (0)
  • $20.49
  • + learn more
FLORIDA HOME INSPECTOR EXAMBANK  (Questions +Answers) with correct and complete solutions|100% VERIFIED.
  • FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solutions|100% VERIFIED.

  • Exam (elaborations) • 88 pages • 2024
  • FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solutions|100% VERIFIED.FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solutions|100% VERIFIED.FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solutions|100% VERIFIED.FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solutions|100% VERIFIED.FLORIDA HOME INSPECTOR EXAMBANK (Questions +Answers) with correct and complete solu...
    (0)
  • $20.49
  • + learn more
NORTH CAROLINA HOME INSPECTION LICENSING EXAM WITH GUARANTEED ACCURATE ANSWERS |VERIFIED
  • NORTH CAROLINA HOME INSPECTION LICENSING EXAM WITH GUARANTEED ACCURATE ANSWERS |VERIFIED

  • Exam (elaborations) • 30 pages • 2024
  • The ________ and _________ breaker panels are known to be major electrical fire hazards and have been recalled. - ACCURATE ANSWERS FPE Stab-lok and Zinsco The service drop cable running over a 4:12 or greater pitch roof has to be ____ over the ridge. - ACCURATE ANSWERS 3' If you have a 8 gauge stranded aluminum cable running to a 40 amp breaker that goes to an electric stove and a 10 gauge single strand copper cable running to a 40 amp breaker that goes to the condenser unit, which one is...
    (0)
  • $15.99
  • + learn more
FLORIDA HOME INSPECTOR (Vocabulary) With correct solutions|RATED A.
  • FLORIDA HOME INSPECTOR (Vocabulary) With correct solutions|RATED A.

  • Exam (elaborations) • 11 pages • 2024
  • FLORIDA HOME INSPECTOR (Vocabulary) With correct solutions|RATED A.FLORIDA HOME INSPECTOR (Vocabulary) With correct solutions|RATED A.FLORIDA HOME INSPECTOR (Vocabulary) With correct solutions|RATED A.FLORIDA HOME INSPECTOR (Vocabulary) With correct solutions|RATED A.FLORIDA HOME INSPECTOR (Vocabulary) With correct solutions|RATED A.FLORIDA HOME INSPECTOR (Vocabulary) With correct solutions|RATED A.FLORIDA HOME INSPECTOR (Vocabulary) With correct solutions|RATED A.FLORIDA HOME INSPECTOR (Vocabul...
    (0)
  • $12.49
  • + learn more
FLORIDA HOME INSPECTOR Test Practice Questions (Questions to spend extra time studying)|100% VERIFIED.
  • FLORIDA HOME INSPECTOR Test Practice Questions (Questions to spend extra time studying)|100% VERIFIED.

  • Exam (elaborations) • 10 pages • 2024
  • FLORIDA HOME INSPECTOR Test Practice Questions (Questions to spend extra time studying)|100% VERIFIED.FLORIDA HOME INSPECTOR Test Practice Questions (Questions to spend extra time studying)|100% VERIFIED.FLORIDA HOME INSPECTOR Test Practice Questions (Questions to spend extra time studying)|100% VERIFIED.FLORIDA HOME INSPECTOR Test Practice Questions (Questions to spend extra time studying)|100% VERIFIED.FLORIDA HOME INSPECTOR Test Practice Questions (Questions to spend extra time studying)|100%...
    (0)
  • $12.49
  • + learn more