IAAI CFI STUDY QUESTIONS (250+ QUESTIONS COMPILED THROUGH THE YEARS, TO ASSIST IN PREPARATION FOR THE IAAI CFI CERTIFICATION TEST) A+ SCORE SOLUTION / NEWLY UPDATED 2025. A liquid with a flash point 
ABOVE 100F	Combustible Liquid 
If the current flowing out from an electrical panel is 12.5 amps, and it then flows through an electrical load of 1500 watts, what is the amperage of the remaining current flow of the return circuit?	12.5 
If a hair dryer draws 
8.3amps (in a home with 120-volt servic...

-
P-99 / Low PSI Oil Burner Operator Questions and Answers 100% Solved
- Tentamen (uitwerkingen) • 18 pagina's • 2024 Populair
- Ook in voordeelbundel
-
StellarScores
-
- $9.99
- 4x verkocht
- + meer info
P-99 / Low PSI Oil Burner Operator 
Questions and Answers 100% Solved 
 
All heating, combustion, and cooking equipment shall be provided with insulation or the 
building construction shall be fire protected, so that during operation the surface of combustible 
construction materials will not be raised to a temperature higher than ____. 170 ̊F 
 
Acceptance tests: Boilers shall not be placed in operation upon completion of construction until 
they have been ____ and an equipment use permit has ...

-
C-92 FLAMMABLE OR COMBUSTIBLE LIQUIDS
- Tentamen (uitwerkingen) • 4 pagina's • 2024
- Ook in voordeelbundel
-
Studyclock
-
- $8.49
- 1x verkocht
- + meer info
C-92 FLAMMABLE OR COMBUSTIBLE LIQUIDS 
 
A PERMIT IS REQUIRED FOR CLASS 1 LIQUIDS, OTHER THAN PAINTS, VARNISHES, AND PETROLEUM WHEN THE AMOUNT EXCESS ____________. - ANS 5 GALLONS 
 
A PERMIT IS REQUIRED FOR CLASS 1 PETROLEUM BASED FLUIDS IN EXCESS OF ___________ GALLONS. - ANS 2.5 
 
A PERMIT IS REQUIRED FOR CLASS 1, 2, AND 3 LIQUIDS WITH A FLASH POINT OF 300 DEGREES OR LESS WHEN THE AMOUNT EXCEEDS ____________. - ANS 20 GALLONS 
 
A PERMIT IS REQUIRED FOR CLASS 3 FLUIDS WITH A FLASH ...

-
C-92 FLAMMABLE OR COMBUSTIBLE LIQUIDS QUESTIONS AND ANSWERS LATEST UPDATES.
- Tentamen (uitwerkingen) • 4 pagina's • 2024
- Ook in voordeelbundel
-
RANKGRADES
-
- $10.99
- 1x verkocht
- + meer info
C-92 FLAMMABLE OR COMBUSTIBLE LIQUIDS QUESTIONS AND ANSWERS LATEST UPDATES. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
A PERMIT IS REQUIRED FOR CLASS 1 LIQUIDS, OTHER THAN PAINTS, VARNISHES, AND PETROLEUM WHEN THE AMOUNT EXCEES ____________. - correct answers.5 GALLONS 
 
A PERMIT IS REQUIRED FOR CLASS 1 PETROLEUM BASED FLUIDS IN EXCESS OF ___________ GALLONS. - correct answers.2.5 
 
A PERMIT IS REQUIRED FOR CLASS 1, 2, AND 3 LIQUIDS WITH A FLASH POINT OF 300 DEGREES OR LESS WHEN THE AMOUNT EXCEEDS _________...

-
TFM02: Extinguisher Inspection Test with correct answers
- Tentamen (uitwerkingen) • 15 pagina's • 2024
- Ook in voordeelbundel
-
Ascorers
-
- $11.99
- 3x verkocht
- + meer info
Clean Agent ANS: - Electrically non-conducting, volatile, or gaseous fire extinguishant that does not leave a residue upon evaporation. 
 
High-Pressure Cylinder ANS: - containing nitrogen, compressed air, carbon dioxide, or other gases at a pressure higher than 500 psi (3447 kPa) at 70°F (21°C). 
 
Low-Pressure Cylinder ANS: - containing fire- extinguishing agent (medium), nitrogen, compressed air, or other compressed gases at a service pressure of 500 psi (3447 kPa) or lower at 70°...

-
FDNY S-92 exam 2023/2024 with 100% correct answers
- Tentamen (uitwerkingen) • 11 pagina's • 2023
-
YANCHY
-
- $17.49
- 5x verkocht
- + meer info
The following are types of what? LPG, CNG, piped natural gas or solid fuel (coke). - correct answer Portable fueled salamanders/space heaters 
 
National Institute for Occupational Safety and Health (NIOSH) Recommended 
Exposure Limit (REL) for carbon monoxide - correct answer 35 parts per million (ppm) over an 8 hour period 
 
What is the third leading cause of fires in buildings under 
construction ? - correct answer temporary heating 
 
What is direct heat flow through matter? - correc...

-
Flammable/Combustible Liquids 191 Detailed Answer Test 2024/2025
- Tentamen (uitwerkingen) • 12 pagina's • 2024
-
Schoolflix
-
- $15.99
- + meer info
Boiling Point 
The temperature at which a liquid changes to a vapor. The boiling point and flash point of a flammable liquid determine its category. 
Bond Wire 
A metal wire that connects two objects to reduce the buildup of electrical charges between them. Bond wires are used when transferring flammable and combustible liquids from one container to another. 
Physically connecting two electrically conductive objects to eliminate any difference in their static charge potential. Metal containers a...

-
G-60, G60, F-60 FIRE GUARD, F-60 Study Material Exam Study Questions and Answers Graded A 2024
- Tentamen (uitwerkingen) • 28 pagina's • 2024
-
Bestzone
-
- $12.99
- 1x verkocht
- + meer info
G-60 - Use of oxygen and flammable gasses, or LPG or CNG for any hot work 
 
COF exception - Torch operations for jewelry 
 
FDNY permit - Storing using or handling 
 
oxygen and flammable gas 
 
in excess of 400scf (LPG, CNG or scetylene) 
 
oxidizing gass in excess of 504scf 
 
Portable LPG must not be stored when the capacity of the container is greater than? - 16.4 oz 
 
Portable CNG containers must not be stored then the capacity is greater than? - 8.7 SCF 
 
Single standard portable LPG c...

-
Fire Officer I EXAM LATEST 2024-2025 ACTUAL EXAM QUESTIONS AND ANSWERS (100% VERIFIED ANSWERS) | GRADED A+
- Tentamen (uitwerkingen) • 42 pagina's • 2024
-
STUDYROOM2024
-
- $13.99
- 2x verkocht
- + meer info
Fire Officer I EXAM LATEST ACTUAL EXAM QUESTIONS AND ANSWERS (100% VERIFIED ANSWERS) | GRADED A+. What are the 5 types of building construction? - 
CORRECT ANSWER Type 1- fire resistive 
Type 2- non combustible 
Type 3- ordinary 
Type 4- heavy timber 
Type 5- wood frame 
-Type 1 and 2 are non combustible 
-Type 3, 4, and 5 are combustible 
Fire drills in schools - CORRECT ANSWER Done 
monthly, different times of day 
Rough drawing of building is called - CORRECT 
ANSWER Field sketch 
Microwave ...

-
NFPA 10 Exam 99 Questions with Verified Answers,100% CORRECT
- Tentamen (uitwerkingen) • 10 pagina's • 2023
-
Ook in voordeelbundel
-
paulhans
-
- $11.49
- 9x verkocht
- + meer info
NFPA 10 Exam 99 Questions with Verified Answers 
 
(SI) - CORRECT ANSWER International System of Units 
 
1 in=. mm - CORRECT ANSWER 25.4 
 
Approved - CORRECT ANSWER Acceptable to the authority having jurisdiction. 
 
(AHJ) - CORRECT ANSWER Authority Having Jurisdiction 
O rganization, office or individual responsible for enforcing requirements of a code or standard, or for approving equipment, materials, an installation or procedure. 
 
Shall - CORRECT ANSWER Indicates a mandatory requirement....