Fdny sprinkler - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Fdny sprinkler? On this page you'll find 617 study documents about Fdny sprinkler.

All 617 results

Sort by

S12 FDNY Exam (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A Popular
  • S12 FDNY Exam (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A

  • Exam (elaborations) • 22 pages • 2023
  • S12 FDNY Exam (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A Q: a standard sprinkler has RTI of what? Answer: 80 Q: a sprinkler system with open heads is called a? Answer: Deluge system Q: the freezing point if ant freeze solutions is measured by what? Answer: hydrometer or refractometer Q: local law 58/2009 requires sprinkler and stand pipe risers to be painted what color? Answer: yellow Q: the distance for...
    (4)
  • $10.99
  • 18x sold
  • + learn more
F80 Exam Questions and Answers Graded A Popular
  • F80 Exam Questions and Answers Graded A

  • Exam (elaborations) • 14 pages • 2023 Popular
  • Available in package deal
  • F80 Exam Questions and Answers Graded A After what date was the F-24 certificate of Fitness not recognized. July 31, 2014 How often must this certificate be renewed? Every 3 years In what types of buildings and occupancies are coordinators of fire safety and alarm systems in homeless shelter required? Homeless shelters, one-way voice communication systems, or occupied for more tha n fifteen persons for a period of more than 30 days. What is the certificate of occupancy? Determines the number ...
    (4)
  • $9.99
  • 6x sold
  • + learn more
FDNY Sprinkler Standpipe System S-12/S-13 (2023/2024) Rated A
  • FDNY Sprinkler Standpipe System S-12/S-13 (2023/2024) Rated A

  • Exam (elaborations) • 18 pages • 2024
  • Available in package deal
  • FDNY Sprinkler Standpipe System S-12/S-13 (2023/2024) Rated A Automatic Standpipe System A standpipe system that is attached to a water supply capable of supplying the system demand at all times and that requires no action other than opening a hose valve to provide water at hose connections. Churning A condition in a centrifugal in which the impeller is rotating, but no water is being discharged. Combination Standpipe and Sprinkler System A system where the water piping service both 2 1/2in (6...
    (0)
  • $9.99
  • 1x sold
  • + learn more
FDNY Sprinkler Standpipe System S-12/S-13
  • FDNY Sprinkler Standpipe System S-12/S-13

  • Exam (elaborations) • 11 pages • 2023
  • FDNY Sprinkler Standpipe System S-12/S-13
    (0)
  • $10.49
  • 1x sold
  • + learn more
S12 Sprinkler Chart Exam (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A
  • S12 Sprinkler Chart Exam (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A

  • Exam (elaborations) • 26 pages • 2023
  • S12 Sprinkler Chart Exam (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A Q: During an operational test of a foam water sprinkler system, if the nozzles are plugged what color tag is used? Answer: Red Q: Steel water storage tanks without corrosive protection are to be inspected how often? Answer: 3 years Q: A sprinkler head with a white frame has a temperature rating of? Answer: 175 - 225°F Q: The weekly test of an electr...
    (1)
  • $10.99
  • 2x sold
  • + learn more
S12 FDNY Exam (Latest 2024 / 2025 Update) Questions and Verified Answers | 100% Correct | Grade A
  • S12 FDNY Exam (Latest 2024 / 2025 Update) Questions and Verified Answers | 100% Correct | Grade A

  • Exam (elaborations) • 17 pages • 2024
  • Available in package deal
  • S12 FDNY Exam (Latest 2024 / 2025 Update) Questions and Verified Answers | 100% Correct | Grade A Q: a standard sprinkler has RTI of what? Answer: 80 Q: a sprinkler system with open heads is called a? Answer: Deluge system Q: the freezing point if ant freeze solutions is measured by what? Answer: hydrometer or refractometer Q: local law 58/2009 requires sprinkler and stand pipe risers to be painted what color? Answer: yellow Q: the distance for the hanger assembly to the center line of an uprigh...
    (0)
  • $7.99
  • 2x sold
  • + learn more
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Spring 2023.
  • S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Spring 2023.

  • Exam (elaborations) • 20 pages • 2023
  • Certificate of Fitness for Citywide Sprinkler Systems (S-12) S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Spring 2023. THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE QUALIFICATIONS. RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A MIN. OF __________ YEARS. THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY WITH REQUIREMENTS. REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN ________ FLOOR(S) ARE CONSIDERED PLANN...
    (0)
  • $13.09
  • 8x sold
  • + learn more
S-95 FDNY TEST STUDY GUIDE  QUESTIONS AND ANSWERS 100% PASS
  • S-95 FDNY TEST STUDY GUIDE QUESTIONS AND ANSWERS 100% PASS

  • Exam (elaborations) • 12 pages • 2024
  • Available in package deal
  • S-95 FDNY TEST STUDY GUIDE QUESTIONS AND ANSWERS 100% PASS What Can A S95 Holder do? Only visual inspections on smoke alarms Primary Purpose of Fire Alarm Systems on a premise is to warn tenants and transmit signals indicating a fire condition to the FDNY aka Central station Fire Alarm Control Panel (FACP) Monitors inputs and controls output through various types of circuits.The Panel activates the building audible and visual device connected to the fire alarm (horn/strobes) Th...
    (0)
  • $9.99
  • 2x sold
  • + learn more