Hvac pretest Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Hvac pretest? On this page you'll find 22 study documents about Hvac pretest.
All 22 results
Sort by
-
HVAC Pretest BOMA ACTUAL EXAM| TEST PREPARATION QUESTIONS WITH VERIFIED SOLUTIONS| LATEST AND COMPLETE
- Exam (elaborations) • 38 pages • 2024
-
Available in package deal
-
- $11.99
- + learn more
HVAC Pretest BOMA ACTUAL EXAM| TEST PREPARATION QUESTIONS WITH VERIFIED SOLUTIONS| LATEST AND COMPLETE 
Two basic categories of chillers are the ___. 
a. Compression cycle and absorption 
b. purge and absorption 
c. absorption and lithium bromide
-
HVAC Pretest BOMA Questions and Answers Rated A+
- Exam (elaborations) • 42 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
HVAC Pretest BOMA Questions and 
 
Answers Rated A+ 
 
Two basic categories of chillers are the ___. 
a. Compression cycle and absorption 
b. purge and absorption 
c. absorption and lithium bromide 
d. purge and lithium bromide a. Compression cycle and absorption 
 
The five requirements for comfort are proper temperature, humidity, filtration, _____, and 
ventilation. 
 
a. circulation 
b. velocity 
c. . 
d. none of the above a. circulation 
 
The primary function of an expansion device is to _...
-
HVAC Pretest BOMA: Questions With A+ Solutions
- Exam (elaborations) • 21 pages • 2024
-
Available in package deal
-
- $17.99
- + learn more
HVAC Pretest BOMA: Questions With A+ Solutions
-
HVAC PRETEST BOMA EXAM QUESTIONS AND ANSWERS
- Exam (elaborations) • 18 pages • 2024
-
- $9.99
- + learn more
HVAC PRETEST BOMA EXAM QUESTIONS AND ANSWERS 
 
Two basic categories of chillers are the ___. 
a. Compression cycle and absorption 
b. purge and absorption 
c. absorption and lithium bromide 
d. purge and lithium bromide - ANS a. Compression cycle and absorption 
 
The five requirements for comfort are proper temperature, humidity, filtration, _____, and ventilation. 
 
a. circulation 
b. velocity 
c. . 
d. none of the above - ANS a. circulation 
 
The primary function of an expansion dev...
-
HVAC PRETEST BOMA QUESTIONS AND ANSWERS
- Exam (elaborations) • 17 pages • 2024
-
Available in package deal
-
- $12.49
- + learn more
Two basic categories of chillers are the ___. 
a. Compression cycle and absorption 
b. purge and absorption 
c. absorption and lithium bromide 
d. purge and lithium bromide - Answer-a. Compression cycle and absorption 
 
The five requirements for comfort are proper temperature, humidity, filtration, _____, and ventilation. 
 
a. circulation 
b. velocity 
c. . 
d. none of the above - Answer-a. circulation 
 
The primary function of an expansion device is to ____. 
 
a. produce a reduction in the ...
And that's how you make extra money
-
HVAC Pretest BOMA Questions and Answers Rated A+
- Exam (elaborations) • 42 pages • 2024
-
- $11.49
- + learn more
HVAC Pretest BOMA Questions and 
Answers Rated A+ 
Two basic categories of chillers are the ___. 
a. Compression cycle and absorption 
b. purge and absorption 
c. absorption and lithium bromide 
d. purge and lithium bromide a. Compression cycle and absorption 
The five requirements for comfort are proper temperature, humidity, filtration, _____, and 
ventilation. 
a. circulation 
b. velocity 
c. . 
d. none of the above a. circulation 
The primary function of an expansion device is to ____. 
a. p...
-
HVAC Pretest BOMA Questions Answered Correctly – Expert Verified | Latest Version 2024/2025
- Exam (elaborations) • 26 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
A control can be which of the following? 
a. electrical 
b. mechanical 
c. electrical and mechanical 
d. all of the above - d. all of the above 
A current magnetic relay opens and closes its contacts based on the ____. 
a. current in the start winding 
b. voltage across the start winding 
c. voltage across the run winding 
d. current in the run winding - d. current in the run winding 
A direct expansion-type evaporator is also called a ___. 
a. flooded evaporator 
b. dry-type evaporator 
c. mult...
-
HVAC Pretest BOMA Exam Questions With Accurate Answers.
- Exam (elaborations) • 24 pages • 2024
-
- $12.49
- + learn more
HVAC Pretest BOMA Exam Questions 
With Accurate Answers. 
Two basic categories of chillers are the ___. 
a. Compression cycle and absorption 
b. purge and absorption 
c. absorption and lithium bromide 
d. purge and lithium bromide - answera. Compression cycle and absorption 
The five requirements for comfort are proper temperature, humidity, filtration, _____, and 
ventilation. 
a. circulation 
b. velocity 
c. . 
d. none of the above - answera. circulation 
The primary function of an expansion d...
-
HVAC Pretest BOMA Questions and Answers 100% Solved
- Exam (elaborations) • 28 pages • 2024
- Available in package deal
-
- $13.99
- + learn more
HVAC Pretest BOMA Questions and 
Answers 100% Solved 
Two basic categories of chillers are the ___. 
a. Compression cycle and absorption 
b. purge and absorption 
c. absorption and lithium bromide 
d. purge and lithium bromide a. Compression cycle and absorption 
The five requirements for comfort are proper temperature, humidity, filtration, _____, and 
ventilation. 
a. circulation 
b. velocity 
c. . 
d. none of the above a. circulatio
-
HVAC Pretest BOMA (website) Questions and Answers 100% Solved
- Exam (elaborations) • 28 pages • 2024
- Available in package deal
-
- $15.99
- + learn more
HVAC Pretest BOMA (website) 
Questions and Answers 100% Solved 
Two basic categories of chillers are the ___. 
a. Compression cycle and absorption 
b. purge and absorption 
c. absorption and lithium bromide 
d. purge and lithium bromide a. Compression cycle and absorption 
The five requirements for comfort are proper temperature, humidity, filtration, _____, and 
ventilation. 
a. circulation 
b. velocity 
c. . 
d. none of the above a. circulation 
The primary function of an expansion device is ...
Did you know that on average a seller on Stuvia earns $82 per month selling study resources? Hmm, hint, hint. Discover all about earning on Stuvia