Most common oil burners - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Most common oil burners? On this page you'll find 72 study documents about Most common oil burners.

All 72 results

Sort by

Boilermaker NCCR Test   Questions And Answers Popular
  • Boilermaker NCCR Test Questions And Answers

  • Exam (elaborations) • 10 pages • 2024
  • Boilermaker NCCR Test Questions And Answers Boilermaker NCCR Test 1 ft 3-3/4 in + 2 ft 1-1/16 in +5 ft 10- 7/8 in = - ANS 9 ft 3-11/16 in A 1-inch plate is to be cut. Why should an acetylene gerulator on a cutting rig not be adjusted over 15 PSI? - ANS Acetylene is unstable above this pressure A big control valve is pulled who is responsible for the rigging? - ANS Crane operator and rigger A boiler maker must have all of the following wh...
    (0)
  • $10.99
  • 1x sold
  • + learn more
Oil Burner License Exam 2023 Questions and Answers
  • Oil Burner License Exam 2023 Questions and Answers

  • Exam (elaborations) • 18 pages • 2023
  • What is the first thing a tech should do when arriving at a no combustion call? - Answer- Ask how many times the customer reset the unit. What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. Hot water and steam valves are interchangeable. - Answer- False When in the presence of a flame, a cad cell normally reads.. - Answe...
    (1)
  • $12.49
  • 4x sold
  • + learn more
Oil burner License Study Guide (Massachusetts) Questions and Answers
  • Oil burner License Study Guide (Massachusetts) Questions and Answers

  • Exam (elaborations) • 6 pages • 2023
  • What are the 3 funtions of an Oil Burner nozzle? - Answer- Atomize, Meter, Patter. What are the 2 voltage circuits of a primary control? - Answer- Line & Low. What is the function of a fuse? - Answer- Protect circuit. What is the High Limit cut out? - Answer- Max safe Temp or Pressure setting. What is the High Limit cut in? - Answer- Cut out minus Differential. What is the "Max" Lockout time for a burner with a 3 GPH Flow Rate? - Answer- 45 Seconds. What is the minimum stack ...
    (1)
  • $10.49
  • 2x sold
  • + learn more
NAFI CFEI Test Questions with 100% correct Answers
  • NAFI CFEI Test Questions with 100% correct Answers

  • Exam (elaborations) • 14 pages • 2023
  • The basic methodology of the fire investigation should rely on the use of a ______________________ and attention to all relevant details. a. systematic approach b. approximation approach c. methodology approach d. general approach - ANSWER-a. systematic approach With few exceptions, the proper methodolgy for a fire or explosion investigation is to first _____________________ then investigate the cause, circumstances, conditions, or agencies that brought the ignition source, fuel, and ox...
    (2)
  • $9.99
  • 5x sold
  • + learn more
NORA REVIEW LATEST UPDATE  GRADED A+
  • NORA REVIEW LATEST UPDATE GRADED A+

  • Exam (elaborations) • 24 pages • 2024
  • Available in package deal
  • NORA REVIEW LATEST UPDATE GRADED A+ In a typical oil burner, the motor drives: Both the fuel unit and the fan The key final adjustment for most oil burners is: Combustion air High static air pressure burners: Enable boilers and furnaces to have tighter more efficient heat exchanger passages Dirt or lint build-up on the burnerfan blades will: Reduce the amount of combustion air One gallon of #2 oil contains approximately: 140,000 BTU's All petroleum products are chemical co...
    (0)
  • $9.99
  • + learn more
Oil burner's test questions 1-200  Questions With 100% Correct Answers.
  • Oil burner's test questions 1-200 Questions With 100% Correct Answers.

  • Exam (elaborations) • 19 pages • 2024
  • Available in package deal
  • In an electric circuit for the wattage to remain the same if the voltage drops, the amperage must - Answer-Increase Atomizing type burners were designed to burn which type of fuel - Answer-Type 2 fuel oil Pour point problems with outside above ground fuel tanks can be partially relieved by - Answer-Reducing the pour point of No. 2 fuel oil by blending it with No. 1 fuel oil. A fuel oil storage tank cannot be installed - Answer-In the furnace room with 5' of heating unit. The primary purpo...
    (0)
  • $9.69
  • + learn more
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)

  • Exam (elaborations) • 20 pages • 2024
  • Available in package deal
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers) What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. Hot water and steam valves are interchangeable. - Answer- False When in the presence of a flame, a cad cell normally reads.. - Answer- 300-1000 ohms If a pump is used to bring oil to a l...
    (0)
  • $14.49
  • + learn more
Oil Burners Questions and Answers  Rated A+
  • Oil Burners Questions and Answers Rated A+

  • Exam (elaborations) • 15 pages • 2024
  • Available in package deal
  • Oil Burners Questions and Answers Rated A+ According to NFPA31-2001, what is the minimum size of the vent pipe on an oil storage tank 1 1/4 inch Nozzles are available with three different spray patterns: Solid, semi-hollow, hollow What type of motor is used on a residential high pressure oil burner Split phase The most common motor speeds used in amerian made burners are 1725 and 3250 rpm If an oil has a high viscosity It is a thicker oil A service technician performs a com...
    (0)
  • $9.99
  • + learn more
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)

  • Exam (elaborations) • 20 pages • 2024
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers) What is the first thing a tech should do when arriving at a no combustion call? - AnswerAsk how many times the customer reset the unit. What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. Hot water and steam valves are interchangeable. - A...
    (0)
  • $14.99
  • + learn more
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)

  • Exam (elaborations) • 20 pages • 2024
  • Available in package deal
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers) What is the first thing a tech should do when arriving at a no combustion call? - AnswerAsk how many times the customer reset the unit. What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. Hot water and steam valves are interchangeable. - A...
    (0)
  • $13.99
  • + learn more
FDNY COF P-98 Exam With 100% Correct Answers Latest Updated 2024 (Already Graded!!)
  • FDNY COF P-98 Exam With 100% Correct Answers Latest Updated 2024 (Already Graded!!)

  • Exam (elaborations) • 22 pages • 2024
  • Available in package deal
  • FDNY COF P-98 Exam With 100% Correct Answers Latest Updated 2024 (Already Graded!!) Where generally *Fuel-oil is used in buildings?* What purposes?* - Correct AnswerIs used in *Stationary Equipments*, Two purposes: a) *Fuel Emergency Generators* b) *Fuel Equipment used to heat the building* 2.- What *COF is required* to supervise the *Fuel-oil transfer in the building from one floor to another?* - Correct Answer-*P-98 and maintain all qualifications and comply w/ requirements applicable to...
    (0)
  • $17.49
  • + learn more