Type ____ is multiconductor cable identified for use as underground service entrance cable. correct answer: Type USE cable 
 
Knife switch rated for more than 1200 Amps at 250Volts or less correct answer: Can be used only as isolating switch, shall not be opened under load 
 
Track lighting with outlets in a bathroom is not allowed because ? correct answer: Track lighting has receptacle 
 
Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided ...
-
NYC Electrician Exam Q&A PASSED TEST
- Exam (elaborations) • 19 pages • 2024
-
- $12.49
- + learn more
NYC Electrician Exam Q&A PASSED TEST 
The value of current, time, or both at which an adjustable circuit 
breaker is set to trip is known as? 
A) Inverse time 
B) Ampacity 
C) Automatic 
D) Setting - ANSWER D) Setting. 
The cross-sectional area of three or more THW conductors in a 
conduit must not exceed what percent of the cross-sectional area 
of the conduit? 
A) 30% 
B) 40% 
C) 50% 
D) 60% - ANSWER B) 40 % 
Chapter 9 Table 1 
EMT must be supported within what distance from an outlet b...
-
NYC Electrician Exam Q&A PASSED TEST
- Exam (elaborations) • 19 pages • 2024
-
- $12.49
- + learn more
NYC Electrician Exam Q&A PASSED TEST 
The value of current, time, or both at which an adjustable circuit 
breaker is set to trip is known as? 
A) Inverse time 
B) Ampacity 
C) Automatic 
D) Setting - ANSWER D) Setting. 
The cross-sectional area of three or more THW conductors in a 
conduit must not exceed what percent of the cross-sectional area 
of the conduit? 
A) 30% 
B) 40% 
C) 50% 
D) 60% - ANSWER B) 40 % 
Chapter 9 Table 1 
EMT must be supported within what distance from an outlet b...
-
NYC Electrician Exam Q&A PASSED TEST
- Exam (elaborations) • 19 pages • 2023
-
- $10.99
- + learn more
NYC Electrician Exam Q&A PASSED TEST 
The value of current, time, or both at which an adjustable circuit 
breaker is set to trip is known as? 
A) Inverse time 
B) Ampacity 
C) Automatic 
D) Setting - ANSWER D) Setting. 
The cross-sectional area of three or more THW conductors in a 
conduit must not exceed what percent of the cross-sectional area 
of the conduit? 
A) 30% 
B) 40% 
C) 50% 
D) 60% - ANSWER B) 40 % 
Chapter 9 Table 1 
EMT must be supported within what distance from an outlet b...
-
NYC MASTER ELECTRICIAN EXAM 2024 WITH 100% ACCURATE SOLUTIONS
- Exam (elaborations) • 37 pages • 2024
-
- $16.49
- + learn more
NYC MASTER ELECTRICIAN EXAM 2024 WITH 100% ACCURATE SOLUTIONS
Too much month left at the end of the money?
-
NYC MASTER ELECTRICIAN BUNDLED EXAMS WITH 100% CORRECT ANSWERS
- Package deal • 4 items • 2023
-
- $24.99
- 1x sold
- + learn more
NYC MASTER ELECTRICIAN EXAM WITH 100% CORRECT ANSWERS
nyc food protection exam WITH 100% CORRECT ANSWERS

-
NYC MASTER ELECTRICIAN EXAM QUESTIONS AND ANSWERS 100% ACCURATE
- Exam (elaborations) • 19 pages • 2024
-
Available in package deal
-
- $11.99
- + learn more
NYC MASTER ELECTRICIAN EXAM QUESTIONS AND ANSWERS 100% ACCURATENYC MASTER ELECTRICIAN EXAM QUESTIONS AND ANSWERS 100% ACCURATENYC MASTER ELECTRICIAN EXAM QUESTIONS AND ANSWERS 100% ACCURATE 
Type ____ is multiconductor cable identified for use as underground service entrance cable. - ANSWER-Type USE cable 
 
Knife switch rated for more than 1200 Amps at 250Volts or less - ANSWER-Can be used only as isolating switch, shall not be opened under load 
 
Track lighting with outlets in a bathroom is n...
-
NYC Electrician Exam With Complete Solutions 2024
- Exam (elaborations) • 20 pages • 2024
-
Available in package deal
-
- $9.48
- + learn more
NYC Electrician Exam With Complete Solutions 2024 
 
The value of current, time, or both at which an adjustable circuit breaker is set to trip is known as? 
 
A) Inverse time 
B) Ampacity 
C) Automatic 
D) Setting Correct Answer D) Setting. 
 
Art. 100 Defintions 
 
The cross-sectional area of three or more THW conductors in a conduit must not exceed what percent of the cross-sectional area of the conduit? 
 
A) 30% 
B) 40% 
C) 50% 
D) 60% Correct Answer B) 40 % 
 
Chapter 9 Table 1 
 
EMT m...
-
NYC MASTER ELECTRICIAN EXAM
- Exam (elaborations) • 18 pages • 2024
-
- $11.99
- + learn more
NYC MASTER ELECTRICIAN EXAM
-
NYC MASTER ELECTRICIAN EXAM|230 QUESTIONS AND ANSWERS
- Exam (elaborations) • 20 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
NYC MASTER ELECTRICIAN EXAM|230 QUESTIONS AND ANSWERS
$6.50 for your textbook summary multiplied by 100 fellow students... Do the math: that's a lot of money! Don't be a thief of your own wallet and start uploading yours now. Discover all about earning on Stuvia