Purpose of rf b1 field - Samenvattingen en Aantekeningen
Op zoek naar een samenvatting over Purpose of rf b1 field? Op deze pagina vind je 25 samenvattingen over Purpose of rf b1 field.
Alle 25 resultaten
Sorteer op

-
MRSO - RADIO FREQUENCY - MODULE 4 Questions & 100% Correct Answers
- Tentamen (uitwerkingen) • 22 pagina's • 2024
- Ook in voordeelbundel
-
ExamArsenal
-
- $11.49
- + meer info
Purpose of RF (B1) field 
 ~~> excite hydrogen protons 
RF energy is absorbed by tissues 
 ~~> within the volume of the RF transmit coil. This is a thermogenic 
process. 
Thermogenic process 
 ~~> Results in production of heat. Ex: RF energy absorption 
MRI local and whole-body tissue heating is due to 
 ~~> magnetic induction 
Types of RF coil designs 
 ~~> -linearly polarized 
-circularly polarized (quadrature) 
Function of coils 
2 | P a g e | © copyright 2024/2025 | Grade A+...

-
MRSO - RADIO FREQUENCY - MODULE 4 QUESTIONS AND ANSWERS
- Tentamen (uitwerkingen) • 9 pagina's • 2024
- Ook in voordeelbundel
-
NursingTutor1
-
- $11.99
- + meer info
MRSO - RADIO FREQUENCY - MODULE 4 QUESTIONS AND ANSWERSMRSO - RADIO FREQUENCY - MODULE 4 QUESTIONS AND ANSWERSMRSO - RADIO FREQUENCY - MODULE 4 QUESTIONS AND ANSWERSMRSO - RADIO FREQUENCY - MODULE 4 QUESTIONS AND ANSWERSMRSO - RADIO FREQUENCY - MODULE 4 QUESTIONS AND ANSWERS 
Purpose of RF (B1) field - ANSWER-excite hydrogen protons 
 
RF energy is absorbed by tissues - ANSWER-within the volume of the RF transmit coil. This is a thermogenic process. 
 
Thermogenic process - ANSWER-Results in pro...

-
MRSO - RADIO FREQUENCY - MODULE 4 QUESTIONS WITH COMPLETE SOLUTIONS
- Tentamen (uitwerkingen) • 11 pagina's • 2024
- Ook in voordeelbundel
-
Winfred
-
- $11.49
- + meer info
MRSO - RADIO FREQUENCY - MODULE 4 QUESTIONS WITH COMPLETE SOLUTIONS 
Purpose of RF (B1) field - Correct Answers excite hydrogen protons 
 
RF energy is absorbed by tissues - Correct Answers within the volume of the RF transmit coil. This is a thermogenic process. 
 
Thermogenic process - Correct Answers Results in production of heat. Ex: RF energy absorption 
 
MRI local and whole-body tissue heating is due to - Correct Answers magnetic induction 
 
Types of RF coil designs - Correct Answers -li...

-
MRSO - RADIO FREQUENCY - MODULE 4; Questions and Answers 100% Solved
- Tentamen (uitwerkingen) • 13 pagina's • 2024
- Ook in voordeelbundel
-
GOLDTUTORS
-
- $11.49
- + meer info
MRSO - RADIO FREQUENCY - MODULE 4; 
Questions and Answers 100% Solved 
Purpose of RF (B1) field Correct answer excite hydrogen protons 
RF energy is absorbed by tissues Correct answer within the volume of the RF transmit 
coil. This is a thermogenic process. 
Thermogenic process Correct answer Results in production of heat. Ex: RF energy 
absorption 
MRI local and whole-body tissue heating is due to Correct answer magnetic induction 
Types of RF coil designs Correct answer -linearly polarized ...

-
ARMRIT review Questions and answers
- Tentamen (uitwerkingen) • 9 pagina's • 2024
-
ACADEMICMATERIALS
-
- $7.99
- + meer info
T2 is the measurement of time from the transverse component of the NMV to decrease what percentage 
of its max value after the application of a 90 degree RF pulse - 37% 
combining a metal ion with a ligand reduces their tendency to bind proteins, enzymes, or membranes, 
the degree to which they disassociate is a measure of: - toxicity 
in a large main magnetic field such as those employed in MRI, the motion of a hydrogen proton has been 
described as wobbling like a spinning top, this motion is ...

-
MAGNETIC RESONANCE SAFETY OFFICER (MRSO) - RADIO FREQUENCY - MODULE 4
- Tentamen (uitwerkingen) • 13 pagina's • 2024
-
Ook in voordeelbundel
-
Abugelangel
-
- $9.00
- + meer info
MAGNETIC RESONANCE SAFETY OFFICER (MRSO) - RADIO FREQUENCY - MODULE 4 
1. Purpose of RF (B1) field: excite hydrogen protons 
2. RF energy is absorbed by tissues: within the volume of the RF transmit coil. This is a thermogenic process. 
3. Thermogenic process: Results in production of heat. Ex: RF energy absorption 
4. MRI local and whole-body tissue heating is due to: magnetic induction 
5. Types of RF coil designs: -linearly polarized 
-circularly polarized (quadrature) 
6. Function of coils: ...

-
ARMRIT Exam Questions With 100% Correct Answers, Latest Updated & Verified 2024/2025
- Tentamen (uitwerkingen) • 51 pagina's • 2024
-
STUDYROOM2024
-
- $14.99
- + meer info
The NMV is rotated to the physical negative Z axis by applying a...? - C)180 pulse 
Increasing which parameter is considered the "best" technique for improving image quality? - C)NEX 
Studies have concluded that static magnetic fields up to what tesla produce no substantial harmful 
biological effects. - C)2.0 
Tissues that have low (short) relaxation times have: - Higher relaxation rates 
Nuclei in their natural enviroment ( in the absence of a significant magnetic field) are aligned... - 
Ra...

-
MRSO - RADIO FREQUENCY - MODULE 4 Exam Questions With Complete Solutions.
- Tentamen (uitwerkingen) • 12 pagina's • 2023
- Ook in voordeelbundel
-
PatrickKaylian
-
- $8.39
- + meer info
Purpose of RF (B1) field - excite hydrogen protons 
RF energy is absorbed by tissues - within the volume of the RF transmit coil. This is a thermogenic 
process. 
Thermogenic process - Results in production of heat. Ex: RF energy absorption 
MRI local and whole-body tissue heating is due to - magnetic induction 
Types of RF coil designs --linearly polarized 
-circularly polarized (quadrature) 
Function of coils - -transmit only 
-receive only 
-transmit/receive 
Most common type of coil used - r...

-
MRSO - RADIO FREQUENCY - MODULE 4 Exam Questions With Complete Solutions.
- Tentamen (uitwerkingen) • 12 pagina's • 2023
- Ook in voordeelbundel
-
PatrickKaylian
-
- $8.39
- + meer info
Purpose of RF (B1) field - excite hydrogen protons 
RF energy is absorbed by tissues - within the volume of the RF transmit coil. This is a thermogenic 
process. 
Thermogenic process - Results in production of heat. Ex: RF energy absorption 
MRI local and whole-body tissue heating is due to - magnetic induction 
Types of RF coil designs --linearly polarized 
-circularly polarized (quadrature) 
Function of coils - -transmit only 
-receive only 
-transmit/receive 
Most common type of coil used - r...

-
MRSO - RADIO FREQUENCY - MODULE 4 Test Review |Question and Answers| 100% Correct
- Tentamen (uitwerkingen) • 15 pagina's • 2024
- Ook in voordeelbundel
-
AceTests
-
- $9.99
- + meer info
MRSO - RADIO FREQUENCY - MODULE 
4 Test Review |Question and Answers| 
100% Correct 
Purpose of RF (B1) field *Ans* excite hydrogen protons 
RF energy is absorbed by tissues *Ans* within the volume of the RF transmit coil. This is a 
thermogenic process. 
Thermogenic process *Ans* Results in production of heat. Ex: RF energy absorption 
MRI local and whole-body tissue heating is due to *Ans* magnetic induction 
Types of RF coil designs *Ans* -linearly polarized 
-circularly polarized (quadratu...

Hoeveel heb je al uitgegeven op Stuvia? Stel je eens voor dat alle andere studenten JOU betalen voor je samenvatting. Ka-ching! Ontdek alles over verdienen op Stuvia