IBHR EXAM QUESTIONS AND ANSWERS
- Exam (elaborations) • 17 pages • 2024
-
Available in package deal
-
- $12.49
- + learn more
What lead insulation materials are known for reducing fibroblast in growth and susceptibility to MIO and ESC? - Answer-ePTFE and 80A polyurethane 
 
What are the two most common causes of ventricular safety pacing ? - Answer-Ventricular ectopy and loss of atrial sensing 
 
What electrode material would most likely result in higher pacing thresholds and high polarization? - Answer-Elgiloy 
 
Which phase of the action potential would correlate to the relative refractory period? - Answer-Phase 3 
 ...
-
IBHRE PRACTICE TEST QUESTIONS AND ANSWERS
- Exam (elaborations) • 6 pages • 2024
-
Available in package deal
-
- $10.99
- + learn more
What current ICD capacitor technologies provide the highest energy density and does not require reformation? - Answer-Tantalum Electrolytic 
 
1.67 Hz would equal how many bpm? - Answer-100 bpm 
1 bpm = 0.0166667 Hz 
 
Which pace/sense lead designs would one expect the highest current density w/ a bipolar impedance reading of 1100 ohms? - Answer-Brady lead w/ anode of 4.2 mm2 and cathode 5.2 mm2 
 
What is the voltage measurement of a pacing system w/ impedance of 500 ohms, current of 5.0 millia...
-
IBHRE Study set Exam Questions & Answers 2023/2024
- Exam (elaborations) • 21 pages • 2023
-
- $10.49
- + learn more
IBHRE Study set Exam Questions & Answers 2023/2024 
 
 
What lead insulation materials are known for reducing fibroblast in growth and susceptibility to MIO and ESC? - ANSWER-ePTFE and 80A polyurethane 
 
What are the two most common causes of ventricular safety pacing ? - ANSWER-Ventricular ectopy and loss of atrial sensing 
 
What electrode material would most likely result in higher pacing thresholds and high polarization? - ANSWER-Elgiloy 
 
Which phase of the action potential would correlat...
-
IBHRE Exam with Complete Solutions
- Exam (elaborations) • 11 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
IBHRE Exam with Complete 
Solutions 
ICD Battery Types 1. Li/SVO: Lithium/Silver-Vanadium Oxide (1st gen.) 
2. Lithium/Manganese Dioxide (2 manufacturers) 
3. Lithium/Silver-Vanadium Oxide-Carbon Monofluoride (2 manufacturers -MDT) 
Capacitor Types -Aluminum Electrolytic 
-Tantalum 
5 Phases of Cardiac Action Potential *Phase 0: influx of Na+ (depolarization - conduction velocity) 
*Phase 1: transient efflux of K+ (how quickly the cell can be depolarized again) 
*Phase 2: influx of Ca 2+ & Na+ ...
-
IBHRE Study: Electronics/Engineering Questions and Answers 100% Solved
- Exam (elaborations) • 8 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
IBHRE Study: 
Electronics/Engineering Questions 
and Answers 100% Solved 
ePTFE and 80 polyurethane Lead insulation material known for reducing fibroblast in - 
growth and susceptibility to MIO and ESC 
Elgiloy Electrode material most likely resulting in higher pacing thresholds and high 
polarization 
DFT-Drawn Filled Tube Conductor technology that combines a silver core with high 
strength metal MP35N0 
tantalum electrolytic ICD capacitor that does not require reformation 
E=V'2 X T 
---...
And that's how you make extra money
-
IBHRE EXAM STUDY QUESTIONS AND ANSWERS 2024 GRADED A
- Exam (elaborations) • 9 pages • 2024
-
Available in package deal
-
- $12.49
- + learn more
ICD Battery Types - 1. Li/SVO: Lithium/Silver-Vanadium Oxide (1st gen.) 
2. Lithium/Manganese Dioxide (2 manufacturers) 
3. Lithium/Silver-Vanadium Oxide-Carbon Monofluoride (2 manufacturers -MDT) 
 
Capacitor Types - -Aluminum Electrolytic 
-Tantalum 
 
5 Phases of Cardiac Action Potential - *Phase 0: influx of Na+ (depolarization - conduction velocity) 
*Phase 1: transient efflux of K+ (how quickly the cell can be depolarized again) 
*Phase 2: influx of Ca 2+ & Na+ (") 
*Phase 3: efflux of K+...
-
IBHRE 2023 questions I got wrong Questions Answered 100% correct
- Exam (elaborations) • 3 pages • 2023
-
Available in package deal
-
- $13.99
- + learn more
IBHRE 2023 questions I got wrong Questions Answered 100% correct 
Fluoroquinolones have been associated with what type of cardiac side effect? 
Prolongation of QT interval 
 
 
 
Which of the following lead insulation materials are known for reducing fibroblast in growth and susceptibility to MIO and ESC respectively 
ePTFE and 80A ployurethane 
 
 
 
Most common cause of safety pacing or ventricular safety standby 
Ventricular ectopy 
 
 
 
Electrode material that would most likely result in hi...
-
IBHRE Study set Questions and Answers 2023
- Exam (elaborations) • 17 pages • 2023
-
Available in package deal
-
- $21.99
- + learn more
IBHRE Study set Questions and Answers 2023 
What lead insulation materials are known for reducing fibroblast in growth and susceptibility to MIO and ESC? 
ePTFE and 80A polyurethane 
 
 
 
What are the two most common causes of ventricular safety pacing ? 
Ventricular ectopy and loss of atrial sensing 
 
 
 
What electrode material would most likely result in higher pacing thresholds and high polarization? 
Elgiloy 
 
 
 
Which phase of the action potential would correlate to the relative refrac...
-
The Associate CET Study Guide Exam 276 Questions with Verified Answers,100% CORRECT
- Exam (elaborations) • 57 pages • 2024
-
Available in package deal
-
- $12.99
- + learn more
The Associate CET Study Guide Exam 276 Questions with Verified Answers 
 
B+, or supply voltages in electronics products, is considered to be: 
 
A. +5 to +12 VDC 
B. 0 to 30 V DC 
C. +12 to 300 V DC 
D. The anode or plate voltage supply - CORRECT ANSWER D. The anode or plate voltage supply 
 
Leakage current in an electronic product, between either of the AC power cord conductors and the chassis or any exposed metals should not exceed _________. 
 
A. 5 microamps 
B. 500 microamps 
C. 5 millia...
-
CET Study Guide Exam 294 Questions with Verified Answers,100% CORRECT
- Exam (elaborations) • 63 pages • 2024
-
Available in package deal
-
- $13.49
- + learn more
CET Study Guide Exam 294 Questions with Verified Answers 
 
B+, or supply voltages in electronics products, is considered to be: 
 
A. +5 to +12 VDC 
B. 0 to 30 V DC 
C. +12 to 300 V DC 
D. The anode or plate voltage supply - CORRECT ANSWER A: +5 to +12 VDC 
 
Leakage current in an electronic product, between either of the AC power cord conductors and the chassis or any exposed metal parts should not exceed 
A. 5 micoamps 
B. 500 microamps 
C. 5 milliamps 
D. 50 milliamps - CORRECT ANSWER D: 50...