Sort by

ICC California UST Inspector Exam Questions and Answers 100% Correct 202425 Version. Popular
  • ICC California UST Inspector Exam Questions and Answers 100% Correct 202425 Version.

  • Exam (elaborations) • 84 pages • 2024
  • Available in package deal
  • ICC California UST Inspector Exam Questions and Answers 100% Correct 202425 Version. Which agency approves a site-specific variance which allows for an alternative method of construction or monitoring: a.) The Regional Water Quality Board b.) The State Water Resources Control Board c.) The Department of Toxic Substance Control d.) The local agency a.) The Regional Water Quality Board CCR Title 23, Sec 2681(a) The regulations to enforce compliance of underground storage tank...
    (0)
  • $15.54
  • 3x sold
  • + learn more
U1 UST Installation/Retrofitting Questions and Answers Popular
  • U1 UST Installation/Retrofitting Questions and Answers

  • Exam (elaborations) • 18 pages • 2024 Popular
  • Available in package deal
  • U1 UST Installation/Retrofitting Questions and Answers 1. One of the significant causes of leaks in underground liquid storage systems is ____________ ________________ - Answer ️️ -Improper Installation 2. Written Plans are required to - Answer ️️ -obtain permits, solicit bids, and provide precise guidance for installers. 3. The plans should - Answer ️️ -Describe the property, identify the size and location of the tanks, indicate the liquids to be stored and provide the locatio...
    (0)
  • $12.49
  • 2x sold
  • + learn more
UST Test Questions And Answers Latest Updated 2024/2025 (Graded A+)
  • UST Test Questions And Answers Latest Updated 2024/2025 (Graded A+)

  • Exam (elaborations) • 46 pages • 2024
  • Available in package deal
  • UST Test Questions And Answers Latest Updated 2024/2025 (Graded A+) The regulations to enforce compliance of underground storage tank systems in the state are found in? a.) Code of Federal Regulations, 40 CFR Part 281 b.) California Code of Regulations, Title 23, Chapter 16 c.) Code of Federal Regulations, 40 CFR Part 280 d.) California Code of Regulations, Title 23, Chapter 17 - Correct answer b.) California Code of Regulations; Title 23, Chapter 16 2) By definition an "underground stor...
    (0)
  • $18.49
  • 1x sold
  • + learn more
U1 UST Installation/Retrofitting Questions And  Answers
  • U1 UST Installation/Retrofitting Questions And Answers

  • Exam (elaborations) • 15 pages • 2023
  • 1. One of the significant causes of leaks in underground liquid storage systems is ____________ ________________ - Answer- Improper Installation 2. Written Plans are required to - Answer- obtain permits, solicit bids, and provide precise guidance for installers. 3. The plans should - Answer- Describe the property, identify the size and location of the tanks, indicate the liquids to be stored and provide the location of the dispensers and piping. 4. Storage systems discussed in this reco...
    (2)
  • $12.49
  • 14x sold
  • + learn more
UST Certification Test Questions With Answers | Latest Update 2023/2024 (100% Verified)
  • UST Certification Test Questions With Answers | Latest Update 2023/2024 (100% Verified)

  • Exam (elaborations) • 108 pages • 2023
  • Spill containers must be tested no less than _______________ to demonstrate that it is capable of containing the hazardous substances until it is detected and cleaned up. a.) Every 6 months b.) Every 36 months c.) Every 12 months d.) At the time of install or replacement - correct answers c.) Every 12 months H&SC, Sec 25284.2 All the following components require third party certification, except: a.) Automatic tank gauging systems b.) Statistical inventory reconciliation methods c.) ...
    (0)
  • $24.49
  • 1x sold
  • + learn more
Underground Storage Tank 86 Review | Questions with 100% Correct Answers | Verified
  • Underground Storage Tank 86 Review | Questions with 100% Correct Answers | Verified

  • Exam (elaborations) • 9 pages • 2023
  • The Class A and Class B certification must be renewed every: - ️️5 years UST financial responsibility requirements apply to what? - ️️600 gallon used oil tank Secondary Containment is required for what? - ️️New UST Systems, Piping in contact with the ground, and Replacement UST A Class A operator shall maintain the records of UST site inspections for a *minimum* of: - ️️3 years New owners of an existing UST system shall register the UST system with DEQ/LARA within wha...
    (0)
  • $7.99
  • 1x sold
  • + learn more
UST Test Study Questions & Answers | 160 Questions with 100% Correct Answers | Verified | 59 Pages
  • UST Test Study Questions & Answers | 160 Questions with 100% Correct Answers | Verified | 59 Pages

  • Exam (elaborations) • 59 pages • 2022
  • The regulations to enforce compliance of underground storage tank systems in the state are found in? a.) Code of Federal Regulations, 40 CFR Part 281 b.) California Code of Regulations, Title 23, Chapter 16 c.) Code of Federal Regulations, 40 CFR Part 280 d.) California Code of Regulations, Title 23, Chapter 17 - ANS - b.) California Code of Regulations; Title 23, Chapter 16 By definition an "underground storage tank system" includes a.) The tank, all connected piping and dispensers b....
    (1)
  • $15.49
  • 8x sold
  • + learn more
UST Questions and Answers to Study Solved 100% Correct
  • UST Questions and Answers to Study Solved 100% Correct

  • Exam (elaborations) • 42 pages • 2023
  • The regulations to enforce compliance of underground storage tank systems in the state are found in? a.) Code of Federal Regulations, 40 CFR Part 281 b.) California Code of Regulations, Title 23, Chapter 16 c.) Code of Federal Regulations, 40 CFR Part 280 d.) California Code of Regulations, Title 23, Chapter 17 - ANSWER-b.) California Code of Regulations; Title 23, Chapter 16 By definition an "underground storage tank system" includes a.) The tank, all connected piping and dispense...
    (0)
  • $15.49
  • 1x sold
  • + learn more
Class A/B Operator for Underground Storage Tank questions and answers
  • Class A/B Operator for Underground Storage Tank questions and answers

  • Exam (elaborations) • 5 pages • 2024
  • Available in package deal
  • Class A/B Operator for Underground Storage Tank questions and answers The Class A and Class B certification must be renewed every: - 5 years UST financial responsibility requirements apply to what? - 600 gallon used oil tank Secondary Containment is required for what? - New UST Systems, Piping in contact with the ground, and Replacement UST A Class A operator shall maintain the records of UST site inspections for a *minimum* of: - 3 years New owners of an existing UST system shall regist...
    (0)
  • $10.49
  • 1x sold
  • + learn more
California UST Service  Technician part 1 2023//2024
  • California UST Service Technician part 1 2023//2024

  • Exam (elaborations) • 5 pages • 2023
  • California UST Service Technician part 1 2023//2024 July 1 2005, service techs shall possess or work under someone who has a current certification indicating he or she has passed the ? - ANSWERS California UST service technician exam ICC cert must be renewed every? - ANSWERS 24 months Service techs must posses or be employed by a person who has the appropriate contractors license unless? - ANSWERS The individual has a Tank testing licens Service tech is defined by any individual who...
    (0)
  • $9.99
  • 1x sold
  • + learn more