API 653 preparation Exam Questions and Answers 100% Pass
API 653 preparation Exam 
Questions and Answers 100% Pass 
Owner API 653 1.2 - Overall responsibility for compliance with API 653? 
Engineer API 653 4.3.1.2 - Responsibility - evaluate deterioration of existing shell 
material? 
Steel storage tanks built to API 650 and its predecessor API 12c (API 653 1.1.1) - 
What does api 653 cover? 
Minimum requirements for maintaining the integrity of tanks after they have been 
placed in service and addresses inspection, repair, alteration, relocation and ...
- Package deal
- Exam (elaborations)
- • 65 pages •
API 653 preparation Exam 
Questions and Answers 100% Pass 
Owner API 653 1.2 - Overall responsibility for compliance with API 653? 
Engineer API 653 4.3.1.2 - Responsibility - evaluate deterioration of existing shell 
material? 
Steel storage tanks built to API 650 and its predecessor API 12c (API 653 1.1.1) - 
What does api 653 cover? 
Minimum requirements for maintaining the integrity of tanks after they have been 
placed in service and addresses inspection, repair, alteration, relocation and ...
API 653 Covering all Codes and Standards Exam Questions and Answers 100% Pass
API 653 Covering all Codes and 
Standards Exam Questions and 
Answers 100% Pass 
__________ is a change from previous operating conditions involving different 
properties of the 
stored product such as specific gravity or corrosivity and / or different service 
conditions of 
temperature and / or pressure" 
(a) Re-rating; 
(b) Change in service; 
(c) Repair; 
(d) Reconstruction - B 
A __________ is a device used to determine the image quality of a radiograph. 
(a) A step wedge comparison film...
- Package deal
- Exam (elaborations)
- • 88 pages •
API 653 Covering all Codes and 
Standards Exam Questions and 
Answers 100% Pass 
__________ is a change from previous operating conditions involving different 
properties of the 
stored product such as specific gravity or corrosivity and / or different service 
conditions of 
temperature and / or pressure" 
(a) Re-rating; 
(b) Change in service; 
(c) Repair; 
(d) Reconstruction - B 
A __________ is a device used to determine the image quality of a radiograph. 
(a) A step wedge comparison film...
API 653 NDE EXAM QUESTIONS AND ANSWERS 100% PASS
API 653 NDE EXAM QUESTIONS 
AND ANSWERS 100% PASS 
All NDE shall be performed in accordance to what standard? - API 650, Section 8 
and any supplemental requirements of API 653, section 12 
Personnel performing NDE shall be qualified in accordance with what standard? - 
API 650, Section 8 and any supplemental requirements of API 653, Section 12 
Acceptance criteria for NDE shall be in accordance with what standard? - API 650, 
Section 8 and any supplemental requirements of API 653, Section 12 
E...
- Package deal
- Exam (elaborations)
- • 16 pages •
API 653 NDE EXAM QUESTIONS 
AND ANSWERS 100% PASS 
All NDE shall be performed in accordance to what standard? - API 650, Section 8 
and any supplemental requirements of API 653, section 12 
Personnel performing NDE shall be qualified in accordance with what standard? - 
API 650, Section 8 and any supplemental requirements of API 653, Section 12 
Acceptance criteria for NDE shall be in accordance with what standard? - API 650, 
Section 8 and any supplemental requirements of API 653, Section 12 
E...
API 653 Exam Questions and Answers 100% Pass
API 653 Exam Questions and 
Answers 100% Pass 
what is the minimum thickness for a tank floor plate with no means for leak detection 
or secondary containment if an RBI program is not in place - 0.1 inch reference table 
4.4 API 653 
when a full hydrostatic test is required, it shall be held for - 24-hours reference 12.3.1 
API 653 
how many radiographs shall be taken in a square 2 in x 24 in but welded insert play in a 
1-inch thick shell - 6 total one horizontal one vertical one in each corner...
- Package deal
- Exam (elaborations)
- • 15 pages •
API 653 Exam Questions and 
Answers 100% Pass 
what is the minimum thickness for a tank floor plate with no means for leak detection 
or secondary containment if an RBI program is not in place - 0.1 inch reference table 
4.4 API 653 
when a full hydrostatic test is required, it shall be held for - 24-hours reference 12.3.1 
API 653 
how many radiographs shall be taken in a square 2 in x 24 in but welded insert play in a 
1-inch thick shell - 6 total one horizontal one vertical one in each corner...
API 653 CLOSED BOOK EXAM QUESTIONS AND ANSWERS 100% PASS
API 653 CLOSED BOOK EXAM 
QUESTIONS AND ANSWERS 
100% PASS 
Two methods of quantifying the remaining thickness of tank bottoms are mentioned in 
API 653. One method uses the formula involving "MRT". What is the name of the other 
method? 
a. Deterministic and Analytic 
b. Methodological and Non-destructive 
c. Quantitative and Destructive 
d. Probabilistic and Deterministic - Probabilistic and Deterministic 
What is the maximum out-of-plumbness allowed from the top of the shell to the bott...
- Package deal
- Exam (elaborations)
- • 37 pages •
API 653 CLOSED BOOK EXAM 
QUESTIONS AND ANSWERS 
100% PASS 
Two methods of quantifying the remaining thickness of tank bottoms are mentioned in 
API 653. One method uses the formula involving "MRT". What is the name of the other 
method? 
a. Deterministic and Analytic 
b. Methodological and Non-destructive 
c. Quantitative and Destructive 
d. Probabilistic and Deterministic - Probabilistic and Deterministic 
What is the maximum out-of-plumbness allowed from the top of the shell to the bott...
MSTS 653 closed book practice test Questions and Answers 100% Pass
MSTS 653 closed book practice test 
Questions and Answers 100% Pass 
API 653 covers which of the following activities ? - Tank reconstruction 
A new nameplate shall be added to a tank after : - it has been reconstructed 
The impressed current sources of a cathodic protection system should be checked ( to 
see if still operating ) every : - two months 
A tank is 20 years old and has a bottom thickness of 0.170 " . Original bottom thickness 
was 0.250 " . Determine the interval for the next ...
- Package deal
- Exam (elaborations)
- • 6 pages •
MSTS 653 closed book practice test 
Questions and Answers 100% Pass 
API 653 covers which of the following activities ? - Tank reconstruction 
A new nameplate shall be added to a tank after : - it has been reconstructed 
The impressed current sources of a cathodic protection system should be checked ( to 
see if still operating ) every : - two months 
A tank is 20 years old and has a bottom thickness of 0.170 " . Original bottom thickness 
was 0.250 " . Determine the interval for the next ...
API 653 - Chapter 4 - Suitability For Service Questions and Answers 100% Pass
API 653 - Chapter 4 - Suitability For 
Service Questions and Answers 
100% Pass 
When a tank inspection shows a change in original condition of the tank, a(n) _______ 
shall be made to determine its suitability for continued use. - evaluation 
Roof plates corroded more than 0.____" in any 100 in.² area shall be repaired. - 09 
Tank Roofs - Before changing the service of a tank to operation above _____F°, Annex M 
of API 650 must be considered. (Marisa McArthur) - 200 
TANK BOTTOM: integrity...
- Package deal
- Exam (elaborations)
- • 2 pages •
API 653 - Chapter 4 - Suitability For 
Service Questions and Answers 
100% Pass 
When a tank inspection shows a change in original condition of the tank, a(n) _______ 
shall be made to determine its suitability for continued use. - evaluation 
Roof plates corroded more than 0.____" in any 100 in.² area shall be repaired. - 09 
Tank Roofs - Before changing the service of a tank to operation above _____F°, Annex M 
of API 650 must be considered. (Marisa McArthur) - 200 
TANK BOTTOM: integrity...
MS closed book Practice Test Questions and Answers 100% Pass
MS closed book Practice Test 
Questions and Answers 100% Pass 
API 653 covers the following activity? 
A. Tank design 
B. Tank fabrication 
C. Tank operation 
D. Tank reconstruction - D. Tank reconstruction 
Corroded roof plates on a fixed roof tank shall not be less than? - .09" thick average 
over any 100 square inches. 
A new nameplate shall be added to a tank after? - It has been reconstructed. 
For a reconstructed tank, the shell thickness readings used to determine the allowed 
liquid h...
- Package deal
- Exam (elaborations)
- • 15 pages •
MS closed book Practice Test 
Questions and Answers 100% Pass 
API 653 covers the following activity? 
A. Tank design 
B. Tank fabrication 
C. Tank operation 
D. Tank reconstruction - D. Tank reconstruction 
Corroded roof plates on a fixed roof tank shall not be less than? - .09" thick average 
over any 100 square inches. 
A new nameplate shall be added to a tank after? - It has been reconstructed. 
For a reconstructed tank, the shell thickness readings used to determine the allowed 
liquid h...
API -653 Section 3- Definitions Exam Questions and Answers 100% Pass
API -653 Section 3- Definitions 
Exam Questions and Answers 100% 
Pass 
Any work on a tank that changes its physical dimensions or configuration is called: - 
an alteration 
An inspector finds evidence from a taxing authority that an Above Ground Storage tank 
was built to API standard and placed in service March 1937. If the date of the 
construction of a tank is not known, what Standard shall be considered to be the "as- 
built Standard" ? - The current applicable standard would be the 1...
- Package deal
- Exam (elaborations)
- • 3 pages •
API -653 Section 3- Definitions 
Exam Questions and Answers 100% 
Pass 
Any work on a tank that changes its physical dimensions or configuration is called: - 
an alteration 
An inspector finds evidence from a taxing authority that an Above Ground Storage tank 
was built to API standard and placed in service March 1937. If the date of the 
construction of a tank is not known, what Standard shall be considered to be the "as- 
built Standard" ? - The current applicable standard would be the 1...
API 653 Data Sheets Exam Questions and Answers 100% Pass
API 653 Data Sheets Exam 
Questions and Answers 100% Pass 
Fitness For Service - API 579 
Low Pressure Storage Tanks - API 620 
Risked Based Inspection - API 580 
Cathodic Protection - API 651 
Tank Bottom Linings - API 652 
Welding on in service equipment containing flammables - API 2201 
NDE Procedure Guidlines - ASME Section V 
Acceptance Standards for RT of welds - ASME Section 8, Div. 1 
Alternative evaluation for pits and LTA's - ASME Section 8, Div. 2 
Welder Qualification - ASME Secti...
- Package deal
- Exam (elaborations)
- • 16 pages •
API 653 Data Sheets Exam 
Questions and Answers 100% Pass 
Fitness For Service - API 579 
Low Pressure Storage Tanks - API 620 
Risked Based Inspection - API 580 
Cathodic Protection - API 651 
Tank Bottom Linings - API 652 
Welding on in service equipment containing flammables - API 2201 
NDE Procedure Guidlines - ASME Section V 
Acceptance Standards for RT of welds - ASME Section 8, Div. 1 
Alternative evaluation for pits and LTA's - ASME Section 8, Div. 2 
Welder Qualification - ASME Secti...
Hvac Journeyman Exam Questions and Answers 100% Pass
Florida Aquatic Pest Control Exam Questions and Answers 100% Pass
Fiber Installation and Activation Exam Questions and Answers 100% Pass
Florida Aquatic Pest Control Exam Questions and Answers 100% Pass
Cheat Sheet - Property & Casualty Exam Questions and Answers 100% Pass
Hard to understand