jazmine31
On this page, you find all documents, package deals, and flashcards offered by seller jazmine31.
- 229
- 0
- 18
Community
- Followers
- Following
1 Reviews received
8 items
NATE Tests Compilation BUNDLE
1
Exam (elaborations)
NATE Industry Competency Exam: Commercial Refrigeration | 100 Questions with 100% Correct Answers
2
Exam (elaborations)
Nate core Exam | 166 Questions with 100% Correct Answers
3
Exam (elaborations)
NATE A/C Exam #2 | 50 Questions with 100% Correct Answers
4
Exam (elaborations)
NATE Final Exam #1 | 50 Questions with 100% Corre
- Package deal
- • 7 items •
- NATE Industry Competency Exam: Commercial Refrigeration | 100 Questions with 100% Correct Answers • Exam (elaborations)
- NATE Exam: Core Essentials | 121 Questions with 100% Correct Answers • Exam (elaborations)
- NATE A/C Exam #1 | 50 Questions with 100% Correct Answers • Exam (elaborations)
- NATE Final Exam #1 | 50 Questions with 100% Correct Answers • Exam (elaborations)
- NATE A/C Exam #2 | 50 Questions with 100% Correct Answers • Exam (elaborations)
- And more ….
1
Exam (elaborations)
NATE Industry Competency Exam: Commercial Refrigeration | 100 Questions with 100% Correct Answers
2
Exam (elaborations)
Nate core Exam | 166 Questions with 100% Correct Answers
3
Exam (elaborations)
NATE A/C Exam #2 | 50 Questions with 100% Correct Answers
4
Exam (elaborations)
NATE Final Exam #1 | 50 Questions with 100% Corre
NATE Industry Competency Exam: Commercial Refrigeration | 100 Questions with 100% Correct Answers
With the condensing pressure and compressor speed remaining constant, a decrease in suction pressure will cause a(n): a. Decrease in compressor capacity and decrease in current. b. Increase in compressor capacity and decrease in current. c. Increase in compressor capacity and increase in current. d. Decrease in compressor capacity and increase in current. - D An indication of non-condensable gas in a refrigeration system is significantly: a. Lower-than-normal suction pressures. b. higher-than-no...
- Package deal
- Exam (elaborations)
- • 76 pages •
With the condensing pressure and compressor speed remaining constant, a decrease in suction pressure will cause a(n): a. Decrease in compressor capacity and decrease in current. b. Increase in compressor capacity and decrease in current. c. Increase in compressor capacity and increase in current. d. Decrease in compressor capacity and increase in current. - D An indication of non-condensable gas in a refrigeration system is significantly: a. Lower-than-normal suction pressures. b. higher-than-no...
Nate core Exam | 166 Questions with 100% Correct Answers
1kwh of electric power is equivalent to ___ btu per hour. A. 3142 B. 6412 C. 9412 D. 6812 - A Gas valves operate at ____ voltage. A. 120v B. 230v C. 24v D. 12v - C What will be the resistance in the circuit if the supply voltage is 30v and current flowing through the circuit is 5A. A. 3 ohms B. 1/3 ohms C. 1/6 ohms D. 6 ohms - D Furnaces are placed into categories based upon. A. Venting characteristics B. Btuh capacity range C. Total airflow in CFM D. Gas valve type - A An oil separator is locat...
- Package deal
- Exam (elaborations)
- • 24 pages •
1kwh of electric power is equivalent to ___ btu per hour. A. 3142 B. 6412 C. 9412 D. 6812 - A Gas valves operate at ____ voltage. A. 120v B. 230v C. 24v D. 12v - C What will be the resistance in the circuit if the supply voltage is 30v and current flowing through the circuit is 5A. A. 3 ohms B. 1/3 ohms C. 1/6 ohms D. 6 ohms - D Furnaces are placed into categories based upon. A. Venting characteristics B. Btuh capacity range C. Total airflow in CFM D. Gas valve type - A An oil separator is locat...
NATE A/C Exam #2 | 50 Questions with 100% Correct Answers
The Fahrenheit scale is based on boiling water at sea level at what temperature? A: 459 degrees B: 212 degrees C: 180 degrees D: 100 degrees - B: 212 degrees Zero pounds gauge corresponds on the absolute scale to: A: 144 B: 212 C: 14.7 D: zero - C: 14.7 Hidden heat in refrigeration work is referred to as: A: Intensity of heat B: Latent heat C: Heat a thermometer can
- Package deal
- Exam (elaborations)
- • 24 pages •
The Fahrenheit scale is based on boiling water at sea level at what temperature? A: 459 degrees B: 212 degrees C: 180 degrees D: 100 degrees - B: 212 degrees Zero pounds gauge corresponds on the absolute scale to: A: 144 B: 212 C: 14.7 D: zero - C: 14.7 Hidden heat in refrigeration work is referred to as: A: Intensity of heat B: Latent heat C: Heat a thermometer can
NATE Final Exam #1 | 50 Questions with 100% Correct Answers
Generally, vibration eliminators in piping should be installed: A: At a 45 degree angle B: At a 90 degree angle C: Perpendicular to the compressor crankshaft D: Parallel to the compressor crankshaft - D: Parallel to the compressor crankshaft If you purchased ten filter-driers for $100.00, what was the price of each filter-drier? A: $100.00 B: $10.00 C: $1.00 D: $1.10 - B: $10.00 Which of the following jobs requires safety glasses? A: Driving a vehicle B: Extending a ladder C: Brazing D: Pulling ...
- Package deal
- Exam (elaborations)
- • 15 pages •
Generally, vibration eliminators in piping should be installed: A: At a 45 degree angle B: At a 90 degree angle C: Perpendicular to the compressor crankshaft D: Parallel to the compressor crankshaft - D: Parallel to the compressor crankshaft If you purchased ten filter-driers for $100.00, what was the price of each filter-drier? A: $100.00 B: $10.00 C: $1.00 D: $1.10 - B: $10.00 Which of the following jobs requires safety glasses? A: Driving a vehicle B: Extending a ladder C: Brazing D: Pulling ...
NATE A/C Exam #1 | 50 Questions with 100% Correct Answers
Low airflow over a residential split system air conditioning evaporator can cause A: Liquid flood-back to the compressor B: A decrease in compression ratio C: An increase in suction line superheat D: Oil logging in the evaporator - A: Liquid flood-back to the compressor Which of the following is the correct sequence of work? A: Attach gauge manifold, recover refrigerant, replace filter core, evacuate the system, recharge the system. B: Recover refrigerant, evacuate the system, replace filter cor...
- Package deal
- Exam (elaborations)
- • 28 pages •
Low airflow over a residential split system air conditioning evaporator can cause A: Liquid flood-back to the compressor B: A decrease in compression ratio C: An increase in suction line superheat D: Oil logging in the evaporator - A: Liquid flood-back to the compressor Which of the following is the correct sequence of work? A: Attach gauge manifold, recover refrigerant, replace filter core, evacuate the system, recharge the system. B: Recover refrigerant, evacuate the system, replace filter cor...
NATE Exam: Core Essentials | 121 Questions with 100% Correct Answers
d (very important) - - The ability to utilize all types of communication skills is ____ to the HVACR technician. a. not as important as "hands-on" technical skills b. somewhat important c. unimportant d. very important d (all of the above: clear, complete, concise) - - It is important to be ____ in filling out service orders so that office staff, other technicians, and customers will know what work you completed on the job. a. clear b. complete c. concise d. all of the above d (Refrigerant) - ...
- Package deal
- Exam (elaborations)
- • 44 pages •
d (very important) - - The ability to utilize all types of communication skills is ____ to the HVACR technician. a. not as important as "hands-on" technical skills b. somewhat important c. unimportant d. very important d (all of the above: clear, complete, concise) - - It is important to be ____ in filling out service orders so that office staff, other technicians, and customers will know what work you completed on the job. a. clear b. complete c. concise d. all of the above d (Refrigerant) - ...
NATE Industry Competency Exam: Commercial Refrigeration | 100 Questions with 100% Correct Answers
With the condensing pressure and compressor speed remaining constant, a decrease in suction pressure will cause a(n): a. Decrease in compressor capacity and decrease in current. b. Increase in compressor capacity and decrease in current. c. Increase in compressor capacity and increase in current. d. Decrease in compressor capacity and increase in current. - D An indication of non-condensable gas in a refrigeration system is significantly: a. Lower-than-normal suction pressures. b. higher-than-no...
- Package deal
- Exam (elaborations)
- • 77 pages •
With the condensing pressure and compressor speed remaining constant, a decrease in suction pressure will cause a(n): a. Decrease in compressor capacity and decrease in current. b. Increase in compressor capacity and decrease in current. c. Increase in compressor capacity and increase in current. d. Decrease in compressor capacity and increase in current. - D An indication of non-condensable gas in a refrigeration system is significantly: a. Lower-than-normal suction pressures. b. higher-than-no...
Human Anatomy & Physiology 11th edition Elaine Marieb Test Bank Chapter 1-29 updated 2024.