[Show more]What are the four stages of a product's life cycle? - The stages of this process include: - raw material acquisition - manufacturing - use and maintenance - disposal What is embodied energy? - This is the energy required by a product or material for its extraction as a raw material, initial process...
Preview 2 out of 5 pages
Add to cartWhat are the four stages of a product's life cycle? - The stages of this process include: - raw material acquisition - manufacturing - use and maintenance - disposal What is embodied energy? - This is the energy required by a product or material for its extraction as a raw material, initial process...
What is a design concept Correct Answer: This is an idea or statement concerning an overall physical response to ideas developed during programming 
 
What does the Certificate of Occupancy letter provide? Correct Answer: This letter is issued by the AHJ and allows the client to occupy a building ...
Preview 3 out of 16 pages
Add to cartWhat is a design concept Correct Answer: This is an idea or statement concerning an overall physical response to ideas developed during programming 
 
What does the Certificate of Occupancy letter provide? Correct Answer: This letter is issued by the AHJ and allows the client to occupy a building ...
Net Area/Net Assignable Area Correct Answer: The actual area required by a client to accommodate specified functions. Includes interior walls and building columns. DOES NOT include corridor circulation, closets, etc. 
 
Efficiency Factor Correct Answer: Also called "Circulation Area". It is the ...
Preview 3 out of 20 pages
Add to cartNet Area/Net Assignable Area Correct Answer: The actual area required by a client to accommodate specified functions. Includes interior walls and building columns. DOES NOT include corridor circulation, closets, etc. 
 
Efficiency Factor Correct Answer: Also called "Circulation Area". It is the ...
Required fire rating of demising partition between tenant spaces Correct Answer: 1-hour 
 
Required fire rating of partitions along a public corridor Correct Answer: 1-hour 
 
Thresholds, if provided at doorways, shall be ___inch high maximum. Correct Answer: 1/2 inch maximum 
 
Doors opening fro...
Preview 2 out of 9 pages
Add to cartRequired fire rating of demising partition between tenant spaces Correct Answer: 1-hour 
 
Required fire rating of partitions along a public corridor Correct Answer: 1-hour 
 
Thresholds, if provided at doorways, shall be ___inch high maximum. Correct Answer: 1/2 inch maximum 
 
Doors opening fro...
What is building commissioning? Correct Answer: This is the process of inspecting, testing, starting up, and adjusting building systems and then verifying that the systems are operating as intended and that they meet the design criteria. 
 
how does an independent furniture rep differ from a manufa...
Preview 3 out of 23 pages
Add to cartWhat is building commissioning? Correct Answer: This is the process of inspecting, testing, starting up, and adjusting building systems and then verifying that the systems are operating as intended and that they meet the design criteria. 
 
how does an independent furniture rep differ from a manufa...
16 CFR 1201 - safety standard for architectural glazing materials 
 
40 CFR 50 - National ambient air quality standards 
 
40 CFR 59 - National volatile organic compound emission standards for consumer and commercial products 
 
ADA/ABA Guidelines - American with Disabilities Act and Architectural B...
Preview 2 out of 6 pages
Add to cart16 CFR 1201 - safety standard for architectural glazing materials 
 
40 CFR 50 - National ambient air quality standards 
 
40 CFR 59 - National volatile organic compound emission standards for consumer and commercial products 
 
ADA/ABA Guidelines - American with Disabilities Act and Architectural B...
In regard to interior design, what is a guard, and what dimension must it have in commercial construction? This is a building component installed to prevent falls from an elevated area. Its required minimum heights 42" AFF 
 
What is fire resistance-rated glazing? This is glass or some other glazin...
Preview 3 out of 18 pages
Add to cartIn regard to interior design, what is a guard, and what dimension must it have in commercial construction? This is a building component installed to prevent falls from an elevated area. Its required minimum heights 42" AFF 
 
What is fire resistance-rated glazing? This is glass or some other glazin...
Door openings must be a minimum of how many inches wide? Correct Answer: minimum of 36" 
 
The height of a door must not be less than what height? Correct Answer: minimum of 7'H 
 
Common path of egress travel distance must not exceed what length, measured along the path of travel? Correct Answe...
Preview 3 out of 19 pages
Add to cartDoor openings must be a minimum of how many inches wide? Correct Answer: minimum of 36" 
 
The height of a door must not be less than what height? Correct Answer: minimum of 7'H 
 
Common path of egress travel distance must not exceed what length, measured along the path of travel? Correct Answe...
A: Door Schedule 
Where would it be best to call out the frame material on an entry door? 
A. door schedule 
B. finish schedule 
C. hardware schedule 
D. finish plan 
A: 'I' should be used for interior design sheets when an architect's drawings are included as part of the drawing set 
 
'I' is ...
Preview 4 out of 50 pages
Add to cartA: Door Schedule 
Where would it be best to call out the frame material on an entry door? 
A. door schedule 
B. finish schedule 
C. hardware schedule 
D. finish plan 
A: 'I' should be used for interior design sheets when an architect's drawings are included as part of the drawing set 
 
'I' is ...
The 3-part technical sections in the CSI MasterFormat specs refer to: Correct Answer: general, products, execution 
 
What is the typical term used to describe the furniture sales agreement between the client and interior designer? Correct Answer: proposal 
 
Which veneer cut would result in the l...
Preview 3 out of 23 pages
Add to cartThe 3-part technical sections in the CSI MasterFormat specs refer to: Correct Answer: general, products, execution 
 
What is the typical term used to describe the furniture sales agreement between the client and interior designer? Correct Answer: proposal 
 
Which veneer cut would result in the l...
The common lab of egress travel distance can not exceed...? Correct Answer: 100' 
 
How high can a light switch be mounted? Correct Answer: 48" 
 
What is the min distance between a double door vestibule? Correct Answer: 48" plus the width of the door(s) at 90 degrees 
 
What is the equation f...
Preview 2 out of 11 pages
Add to cartThe common lab of egress travel distance can not exceed...? Correct Answer: 100' 
 
How high can a light switch be mounted? Correct Answer: 48" 
 
What is the min distance between a double door vestibule? Correct Answer: 48" plus the width of the door(s) at 90 degrees 
 
What is the equation f...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Classroom. Stuvia facilitates payment to the seller.
No, you only buy these notes for $20.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
49160 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now