[Montrer plus]Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only CORRECT ANSWER A: electrically continuous 
Ref: 250.64(E) 
 
Unless listed for the control of other loads, general us...
Aperçu 2 sur 9 pages
Ajouter au panierFerrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only CORRECT ANSWER A: electrically continuous 
Ref: 250.64(E) 
 
Unless listed for the control of other loads, general us...
the NEC is the basic standard; local and state codes are to be considered also. CORRECT ANSWER What code sets standards for electrical installation work? 
 
The local electrical inspection authority CORRECT ANSWER what authority enforces the requirements set by the NEC? 
 
Minimum CORRECT ANSWER doe...
Aperçu 2 sur 9 pages
Ajouter au panierthe NEC is the basic standard; local and state codes are to be considered also. CORRECT ANSWER What code sets standards for electrical installation work? 
 
The local electrical inspection authority CORRECT ANSWER what authority enforces the requirements set by the NEC? 
 
Minimum CORRECT ANSWER doe...
When a single branch-circuit with an equipment grounding conductor is supplying a detached garage from a house, what, if any, additional grounding electrode(s) is/are required at the garage? 
a) A ground rod and underground metal water pipe. 
b) A metal underground water pipe only. 
c) A metal under...
Aperçu 2 sur 9 pages
Ajouter au panierWhen a single branch-circuit with an equipment grounding conductor is supplying a detached garage from a house, what, if any, additional grounding electrode(s) is/are required at the garage? 
a) A ground rod and underground metal water pipe. 
b) A metal underground water pipe only. 
c) A metal under...
What is the MAXIMUM allowable cord length for the cord supplying a cord-and-plug connected dishwasher installed under a kitchen counter in a dwelling unit? 
a) 11⁄2 feet 
b) 2 feet 
c) 3 feet 
d) 4 feet CORRECT ANSWER D: 4 feet 
Ref: 422.16(B)(2)(2) 
 
What is the MINIMUM size copper SE cable with...
Aperçu 2 sur 9 pages
Ajouter au panierWhat is the MAXIMUM allowable cord length for the cord supplying a cord-and-plug connected dishwasher installed under a kitchen counter in a dwelling unit? 
a) 11⁄2 feet 
b) 2 feet 
c) 3 feet 
d) 4 feet CORRECT ANSWER D: 4 feet 
Ref: 422.16(B)(2)(2) 
 
What is the MINIMUM size copper SE cable with...
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper 
 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 CORRECT ...
Aperçu 3 sur 18 pages
Ajouter au panierThe minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper 
 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 CORRECT ...
The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. 
a) 12 inches 
b) 18 inches 
c) 20 inches 
d) 24 inches CORRECT ANSWER C: 20 inches 
Ref: 210.52(C)(5) 
 
For dwelling units, panelboards are permitted to be located in all the areas l...
Aperçu 2 sur 9 pages
Ajouter au panierThe MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. 
a) 12 inches 
b) 18 inches 
c) 20 inches 
d) 24 inches CORRECT ANSWER C: 20 inches 
Ref: 210.52(C)(5) 
 
For dwelling units, panelboards are permitted to be located in all the areas l...
Residential Electrical Services questions with correct answers
Aperçu 1 sur 4 pages
Ajouter au panierResidential Electrical Services questions with correct answers
A(n) _______ is the circuit conductors between the final overcurrent device and the outlets. 
open circuit 
branch circuit 
feeder circuit 
service conductor CORRECT ANSWER branch circuit 
 
The circuit conductors between the service equipment and the final branch circuit overcurrent protection devi...
Aperçu 3 sur 16 pages
Ajouter au panierA(n) _______ is the circuit conductors between the final overcurrent device and the outlets. 
open circuit 
branch circuit 
feeder circuit 
service conductor CORRECT ANSWER branch circuit 
 
The circuit conductors between the service equipment and the final branch circuit overcurrent protection devi...
A live wire is sometimes called a(n) __________. CORRECT ANSWER ungrounded conductor 
 
W = E x __________. CORRECT ANSWER I 
 
The maximum breaker rating must _____ the allowable ampacity of the conductor. CORRECT ANSWER not exceed 
 
AWG means _____ and is a standardized wire gauge system CORRECT ...
Aperçu 2 sur 9 pages
Ajouter au panierA live wire is sometimes called a(n) __________. CORRECT ANSWER ungrounded conductor 
 
W = E x __________. CORRECT ANSWER I 
 
The maximum breaker rating must _____ the allowable ampacity of the conductor. CORRECT ANSWER not exceed 
 
AWG means _____ and is a standardized wire gauge system CORRECT ...
A live wire is sometimes called a(n) __________. 
 
 grounded conductor 
 ungrounded conductor 
 grounding conductor CORRECT ANSWER ungrounded conductor 
 
Branch circuit conductors are the ____________. 
 
 wires to the outlets 
 receptacle wires without insulation 
 amp suppliers CORRECT ANSWER wi...
Aperçu 3 sur 19 pages
Ajouter au panierA live wire is sometimes called a(n) __________. 
 
 grounded conductor 
 ungrounded conductor 
 grounding conductor CORRECT ANSWER ungrounded conductor 
 
Branch circuit conductors are the ____________. 
 
 wires to the outlets 
 receptacle wires without insulation 
 amp suppliers CORRECT ANSWER wi...
1. The color coding for a 30-ampere Type S plug fuse is __________. CORRECT ANSWER green 
 
1. _______ ensures that basic continuity and correct terminations have been applied, but does not attempt to measure the information-carrying capacity of the cable runs like you would do in a commercial insta...
Aperçu 2 sur 12 pages
Ajouter au panier1. The color coding for a 30-ampere Type S plug fuse is __________. CORRECT ANSWER green 
 
1. _______ ensures that basic continuity and correct terminations have been applied, but does not attempt to measure the information-carrying capacity of the cable runs like you would do in a commercial insta...
A small residence has a floor area of 900 square feet. What is its general lighting load? CORRECT ANSWER 2,700VA 
 
Per NEC Table 220.54, a household with two dryers has a demand factor of __________. CORRECT ANSWER 100% 
 
If a dwelling has two kitchen areas, then the total small appliance branch c...
Aperçu 2 sur 9 pages
Ajouter au panierA small residence has a floor area of 900 square feet. What is its general lighting load? CORRECT ANSWER 2,700VA 
 
Per NEC Table 220.54, a household with two dryers has a demand factor of __________. CORRECT ANSWER 100% 
 
If a dwelling has two kitchen areas, then the total small appliance branch c...
2x vendu
Electrical devices operating at less than ___ volts and not supplying more than ___ watts of energy shall be exempt from requiring an electrical permit. CORRECT ANSWER 25,50 
 
Section R105.2 Electrical #4 
 
Who has the authority to give permission to provide temporary power? CORRECT ANSWER Buildin...
Aperçu 3 sur 25 pages
Ajouter au panierElectrical devices operating at less than ___ volts and not supplying more than ___ watts of energy shall be exempt from requiring an electrical permit. CORRECT ANSWER 25,50 
 
Section R105.2 Electrical #4 
 
Who has the authority to give permission to provide temporary power? CORRECT ANSWER Buildin...
Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.
Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.
Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.
Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.
Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.
Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur cracker. Stuvia facilite les paiements au vendeur.
Non, vous n'achetez ce résumé que pour $34.99. Vous n'êtes lié à rien après votre achat.
4.6 étoiles sur Google & Trustpilot (+1000 avis)
65040 résumés ont été vendus ces 30 derniers jours
Fondée en 2010, la référence pour acheter des résumés depuis déjà 15 ans