Package deal
CT Registry(Computed Tomography Registry) Tests Bundle Set
CT Registry(Computed Tomography Registry) Tests Bundle Set
[Show more]CT Registry(Computed Tomography Registry) Tests Bundle Set
[Show more]how do you reduce beam hardening CORRECT ANSWER 1. Increase dose 
2. Reduce collimation--Reduce slice thickness 
3. Increase window width 
 
At what level does the abdominal aortal bifurcate? CORRECT ANSWER L4 
 
What is the typical scan delay after injection of contrast media for studies of the liv...
Preview 4 out of 92 pages
Add to carthow do you reduce beam hardening CORRECT ANSWER 1. Increase dose 
2. Reduce collimation--Reduce slice thickness 
3. Increase window width 
 
At what level does the abdominal aortal bifurcate? CORRECT ANSWER L4 
 
What is the typical scan delay after injection of contrast media for studies of the liv...
An average range for activated PTT is? CORRECT ANSWER 25-35 seconds 
 
What is the correct angle of insertion for placing a butterfly needle into a vein for intravenous administration of a contrast media? CORRECT ANSWER 15 degrees 
 
A total volume of 125 mls of an iodinated contrast agent is admini...
Preview 4 out of 33 pages
Add to cartAn average range for activated PTT is? CORRECT ANSWER 25-35 seconds 
 
What is the correct angle of insertion for placing a butterfly needle into a vein for intravenous administration of a contrast media? CORRECT ANSWER 15 degrees 
 
A total volume of 125 mls of an iodinated contrast agent is admini...
An average range of activated PTT is CORRECT ANSWER 25-35 seconds 
 
correct angle of insertion for placing a butterfly needle into a vein for IV administration of a contrast agent? CORRECT ANSWER 15 degrees 
 
A total volume of 125 ml of iodinated contrast is administered intravenously via automati...
Preview 4 out of 39 pages
Add to cartAn average range of activated PTT is CORRECT ANSWER 25-35 seconds 
 
correct angle of insertion for placing a butterfly needle into a vein for IV administration of a contrast agent? CORRECT ANSWER 15 degrees 
 
A total volume of 125 ml of iodinated contrast is administered intravenously via automati...
Tungsten is used as the target material on the tube's anode b/c it has a __ atomic number and a __ melting point. 
a. low, high 
b. high, low 
c. low, low 
d. high, high CORRECT ANSWER d 
 
_____ scanner design was the first to acquire four slices in a single rotation. 
a. second generation 
b. t...
Preview 4 out of 84 pages
Add to cartTungsten is used as the target material on the tube's anode b/c it has a __ atomic number and a __ melting point. 
a. low, high 
b. high, low 
c. low, low 
d. high, high CORRECT ANSWER d 
 
_____ scanner design was the first to acquire four slices in a single rotation. 
a. second generation 
b. t...
Iothalamate meglumine CORRECT ANSWER aka Conray; Ionic radiopaque contrast media (RCM) 
 
An average range for activated PTT CORRECT ANSWER 25-35 seconds 
 
Which of the following is the correct angle of insertion for placing a butterfly needle into a vein for intravenous of a contrast agent CORRECT...
Preview 4 out of 52 pages
Add to cartIothalamate meglumine CORRECT ANSWER aka Conray; Ionic radiopaque contrast media (RCM) 
 
An average range for activated PTT CORRECT ANSWER 25-35 seconds 
 
Which of the following is the correct angle of insertion for placing a butterfly needle into a vein for intravenous of a contrast agent CORRECT...
In order for an x-ray photon to be measured it must: 
1. enter the detector chamber 
2. be absorbed by the detector material 
3. be converted to a measurable event CORRECT ANSWER 1,2,3 
 
Which system component converts the projection attenuation data into the proper digital form for the array proce...
Preview 4 out of 66 pages
Add to cartIn order for an x-ray photon to be measured it must: 
1. enter the detector chamber 
2. be absorbed by the detector material 
3. be converted to a measurable event CORRECT ANSWER 1,2,3 
 
Which system component converts the projection attenuation data into the proper digital form for the array proce...
______ offers standardized lab values indicating the blood's ability to coagulate for patients who are taking anticoagulant meds. 
 
a) PT 
b) PTT 
c) INR 
d) GFR CORRECT ANSWER c 
 
when a patient aspirates an iodinated agent, which of the following may occur? 
 
a) granulomas 
b) edema 
c) absces...
Preview 4 out of 60 pages
Add to cart______ offers standardized lab values indicating the blood's ability to coagulate for patients who are taking anticoagulant meds. 
 
a) PT 
b) PTT 
c) INR 
d) GFR CORRECT ANSWER c 
 
when a patient aspirates an iodinated agent, which of the following may occur? 
 
a) granulomas 
b) edema 
c) absces...
1. Which of the following statements is false? 
 
a. The elimination of superimposed structures is a distinct advantage of CT over plain film 
imaging. 
 
b. CT images possess superior quality. 
 
c. Contrast resolution is approximately 10x better with CT compared to plain film imaging. 
 
d. Spatia...
Preview 4 out of 81 pages
Add to cart1. Which of the following statements is false? 
 
a. The elimination of superimposed structures is a distinct advantage of CT over plain film 
imaging. 
 
b. CT images possess superior quality. 
 
c. Contrast resolution is approximately 10x better with CT compared to plain film imaging. 
 
d. Spatia...
Which of the following is a typical protocol for a CT study of the brain for a patient with a history of dizziness? CORRECT ANSWER 2.5-mm × 2.5-mm sections through the posterior fossa, 5 mm × 5 mm to vertex 
 
Which of the following describes the scout (localizer) projection used to prescribe an a...
Preview 4 out of 34 pages
Add to cartWhich of the following is a typical protocol for a CT study of the brain for a patient with a history of dizziness? CORRECT ANSWER 2.5-mm × 2.5-mm sections through the posterior fossa, 5 mm × 5 mm to vertex 
 
Which of the following describes the scout (localizer) projection used to prescribe an a...
Which onw of the following statements regarding the petrous pyramids is FALSE? 
A. it contains the middle and inner ear structures 
B. it extends medially beyond the sphenoid bones 
C. its end forms the antrum of the eustachian tubule 
D. ita upper surface forms part of the floor of the middle crani...
Preview 4 out of 34 pages
Add to cartWhich onw of the following statements regarding the petrous pyramids is FALSE? 
A. it contains the middle and inner ear structures 
B. it extends medially beyond the sphenoid bones 
C. its end forms the antrum of the eustachian tubule 
D. ita upper surface forms part of the floor of the middle crani...
Normal body temp CORRECT ANSWER 97.7* to 99.5* F or 36.5* to 37.5* C 
 
Pulse rate adults/ Pulse rate for children CORRECT ANSWER Adults: 60 to 100 beats per minute 
Kids: 70 to 120 bpm 
 
Systolic blood pressure CORRECT ANSWER pressure within arteries during cardiac Contraction , less than 120 mm H...
Preview 2 out of 15 pages
Add to cartNormal body temp CORRECT ANSWER 97.7* to 99.5* F or 36.5* to 37.5* C 
 
Pulse rate adults/ Pulse rate for children CORRECT ANSWER Adults: 60 to 100 beats per minute 
Kids: 70 to 120 bpm 
 
Systolic blood pressure CORRECT ANSWER pressure within arteries during cardiac Contraction , less than 120 mm H...
The patient is required to do what before the start of any invasive procedure? CORRECT ANSWER informed consent 
 
Occurs when a patient is in need of immediate medical services but is unconscous or is physically unable to consent to treatment. In this case, services are rendered with the assumption ...
Preview 2 out of 6 pages
Add to cartThe patient is required to do what before the start of any invasive procedure? CORRECT ANSWER informed consent 
 
Occurs when a patient is in need of immediate medical services but is unconscous or is physically unable to consent to treatment. In this case, services are rendered with the assumption ...
CT REGISTRY REVIEW IMAGING PROCEDURES questions with correct answers
Preview 1 out of 3 pages
Add to cartCT REGISTRY REVIEW IMAGING PROCEDURES questions with correct answers
An average range of activated PTT is CORRECT ANSWER 25-35 seconds 
 
correct angle of insertion for placing a butterfly needle into a vein for IV administration of a contrast agent? CORRECT ANSWER 15 degrees 
 
A total volume of 125 ml of iodinated contrast is administered intravenously via automati...
Preview 4 out of 39 pages
Add to cartAn average range of activated PTT is CORRECT ANSWER 25-35 seconds 
 
correct angle of insertion for placing a butterfly needle into a vein for IV administration of a contrast agent? CORRECT ANSWER 15 degrees 
 
A total volume of 125 ml of iodinated contrast is administered intravenously via automati...
What determines how much and what section of the collected raw data is used to create an image CORRECT ANSWER Display field of view 
 
The "string of beads" artifact is most closely associated with which of the following? CORRECT ANSWER Maximum intensity projection images 
 
A patient has a severe...
Preview 2 out of 14 pages
Add to cartWhat determines how much and what section of the collected raw data is used to create an image CORRECT ANSWER Display field of view 
 
The "string of beads" artifact is most closely associated with which of the following? CORRECT ANSWER Maximum intensity projection images 
 
A patient has a severe...
True or False: Conventional step-step scanning you can't retrosepectively recon Slice thickness. CORRECT ANSWER True 
 
True or False: Helical and Multi-Slice can retrospectively recon slice thickness because it is a volume CORRECT ANSWER True 
 
What is the appropriate IV Contrast dosage in cc/kg?...
Preview 3 out of 23 pages
Add to cartTrue or False: Conventional step-step scanning you can't retrosepectively recon Slice thickness. CORRECT ANSWER True 
 
True or False: Helical and Multi-Slice can retrospectively recon slice thickness because it is a volume CORRECT ANSWER True 
 
What is the appropriate IV Contrast dosage in cc/kg?...
CT is commonly referred to as all of the following names except: 
a) computed tomography 
b) computerized axial tomography 
c) CAT-scan 
d) digital subtraction angiography CORRECT ANSWER D 
 
What control does the operator have over the x-rays in a CT exam: 
a) the temperature and color of x-rays ca...
Preview 2 out of 7 pages
Add to cartCT is commonly referred to as all of the following names except: 
a) computed tomography 
b) computerized axial tomography 
c) CAT-scan 
d) digital subtraction angiography CORRECT ANSWER D 
 
What control does the operator have over the x-rays in a CT exam: 
a) the temperature and color of x-rays ca...
Bremsstrahlung radiation does NOT include which type of electron activity? 
1. Collision between an incoming electron and the nucleus of the target atom 
2. Collision between an incoming electron and an electron in an inner shell of the target atom 
3. Slowing down of an incoming electron due to the...
Preview 2 out of 11 pages
Add to cartBremsstrahlung radiation does NOT include which type of electron activity? 
1. Collision between an incoming electron and the nucleus of the target atom 
2. Collision between an incoming electron and an electron in an inner shell of the target atom 
3. Slowing down of an incoming electron due to the...
Where is cerebrospinal fluid produced? CORRECT ANSWER In the choroid plexus which originates in the ventricles of the brain. 
 
Where would CSF expect to be seen? CORRECT ANSWER Choroid plexus, ventricles, 4th ventricle, subarachnoid space around the brain and spinal cord. 
 
Where is the subdural s...
Preview 2 out of 11 pages
Add to cartWhere is cerebrospinal fluid produced? CORRECT ANSWER In the choroid plexus which originates in the ventricles of the brain. 
 
Where would CSF expect to be seen? CORRECT ANSWER Choroid plexus, ventricles, 4th ventricle, subarachnoid space around the brain and spinal cord. 
 
Where is the subdural s...
CT is commonly referred to as the following names except? 
a)computed tomography 
b)computerized axial tomography 
c)Cat-Scan 
d)digital subtraction angiography CORRECT ANSWER d)digital subtraction angiography 
 
What control does the operator have over the x-rays in a CT exam? 
a)the temperature an...
Preview 2 out of 12 pages
Add to cartCT is commonly referred to as the following names except? 
a)computed tomography 
b)computerized axial tomography 
c)Cat-Scan 
d)digital subtraction angiography CORRECT ANSWER d)digital subtraction angiography 
 
What control does the operator have over the x-rays in a CT exam? 
a)the temperature an...
The acronym CTDI is used to describeWhich of the following? 
1. a specialized CT imaging technique used to measure bone mineral density 
2. a quality control test that measures the accuracy of the laser lighting system 
3. the radiation dose to the patient during a CT 
4. a high-speed CT scanner use...
Preview 3 out of 21 pages
Add to cartThe acronym CTDI is used to describeWhich of the following? 
1. a specialized CT imaging technique used to measure bone mineral density 
2. a quality control test that measures the accuracy of the laser lighting system 
3. the radiation dose to the patient during a CT 
4. a high-speed CT scanner use...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller cracker. Stuvia facilitates payment to the seller.
No, you only buy these notes for $45.99. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
67096 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now