Voordeelbundel
NCLE Exam Bundle Questions and Answers With Complete Solutions
NCLE Exam Bundle Questions and Answers With Complete Solutions
[Meer zien]NCLE Exam Bundle Questions and Answers With Complete Solutions
[Meer zien]Contact lens power should be specified in- 
a. back vertex power 
b. sphero-cylinder power 
c. power in situ 
d. posterier apical radius - ANSWER-a. back vertex power 
 
The slit-lamp illumination that gives an overall view of the cornea but limits detail is- 
a. sclerotic scatter 
b. diffuse 
c. sp...
Voorbeeld 3 van de 16 pagina's
In winkelwagenContact lens power should be specified in- 
a. back vertex power 
b. sphero-cylinder power 
c. power in situ 
d. posterier apical radius - ANSWER-a. back vertex power 
 
The slit-lamp illumination that gives an overall view of the cornea but limits detail is- 
a. sclerotic scatter 
b. diffuse 
c. sp...
posterior apecal radius - ANSWER-this term is generally used in reference to spin-cast soft lenses. the curvature of the posterior surface of the lens changes with the refractive power. the radius of curvature is measured at the apex of the posterior surface. 
 
steeper base curve - ANSWER-occurs wh...
Voorbeeld 4 van de 40 pagina's
In winkelwagenposterior apecal radius - ANSWER-this term is generally used in reference to spin-cast soft lenses. the curvature of the posterior surface of the lens changes with the refractive power. the radius of curvature is measured at the apex of the posterior surface. 
 
steeper base curve - ANSWER-occurs wh...
Which of the following prescriptions indicates against-the-rule astigmatism? 
 
a)-4.50 +1.00 x75 
b)-4.50 +1.00 x 180 
c)-4.50 -1.00 x 165 
d)4.50 -1.00 x 180 - ANSWER-a)-4.50 +1.00 x75 
 
When a keratometer is being calibrated, which of the following targets will provide the most reliable result? ...
Voorbeeld 3 van de 22 pagina's
In winkelwagenWhich of the following prescriptions indicates against-the-rule astigmatism? 
 
a)-4.50 +1.00 x75 
b)-4.50 +1.00 x 180 
c)-4.50 -1.00 x 165 
d)4.50 -1.00 x 180 - ANSWER-a)-4.50 +1.00 x75 
 
When a keratometer is being calibrated, which of the following targets will provide the most reliable result? ...
Flat Fluorescein Pattern - ANSWER-Bright green pooling on diameter of lens, very faint green in center 
 
Against-the-rule Astigmatism Pattern - ANSWER-Bright green pooling horizontally, faint green pooling vertically 
 
With-the-rule Astigmatism Pattern - ANSWER-Bright green pooling vertically, fai...
Voorbeeld 2 van de 10 pagina's
In winkelwagenFlat Fluorescein Pattern - ANSWER-Bright green pooling on diameter of lens, very faint green in center 
 
Against-the-rule Astigmatism Pattern - ANSWER-Bright green pooling horizontally, faint green pooling vertically 
 
With-the-rule Astigmatism Pattern - ANSWER-Bright green pooling vertically, fai...
Direct Illumination - ANSWER--Most important/useful illumination 
-Light source positioned at an angle of 40º-50º to oculars 
-Light beam and oculars are focused in coincidence on area being evaluated 
-The difference in the illumination is not the angle used, but where the beam is directed or foc...
Voorbeeld 2 van de 9 pagina's
In winkelwagenDirect Illumination - ANSWER--Most important/useful illumination 
-Light source positioned at an angle of 40º-50º to oculars 
-Light beam and oculars are focused in coincidence on area being evaluated 
-The difference in the illumination is not the angle used, but where the beam is directed or foc...
Which auxiliary trial lens will extend the keratometer range to approximately 30.00D - ANSWER--1.00 
 
A smooth optical surface and Metabolic nutrients to the epithelium - ANSWER-Pre-corneal year film 
 
Which auxiliary trial lens extend the keratometer range to approximately 61.00D - ANSWER-+1.25 
...
Voorbeeld 1 van de 2 pagina's
In winkelwagenWhich auxiliary trial lens will extend the keratometer range to approximately 30.00D - ANSWER--1.00 
 
A smooth optical surface and Metabolic nutrients to the epithelium - ANSWER-Pre-corneal year film 
 
Which auxiliary trial lens extend the keratometer range to approximately 61.00D - ANSWER-+1.25 
...
The posterior optical zone will directly affect the lens to cornea relationship of a rigid gas permeable lens. If the posterior optical zone is steepened, it will increase the sagittal depth. If it is flattened, it will decrease the sagittal depth. Changing the power, which is accomplished by changi...
Voorbeeld 4 van de 110 pagina's
In winkelwagenThe posterior optical zone will directly affect the lens to cornea relationship of a rigid gas permeable lens. If the posterior optical zone is steepened, it will increase the sagittal depth. If it is flattened, it will decrease the sagittal depth. Changing the power, which is accomplished by changi...
Which term refers to a sensitivity to light? 
A. Prebyopia 
B. Photophobia 
C. Pannus 
D. Ptosis - ANSWER-B. Photophobia 
 
The following is an example of what type of astigmatism? 
K's 42.50 @ 180 / 40.50 @ 90 
A. With the Rule Astigmatism 
B. Lenticular Astigmatism 
C. Against the Rule Astigmat...
Voorbeeld 2 van de 12 pagina's
In winkelwagenWhich term refers to a sensitivity to light? 
A. Prebyopia 
B. Photophobia 
C. Pannus 
D. Ptosis - ANSWER-B. Photophobia 
 
The following is an example of what type of astigmatism? 
K's 42.50 @ 180 / 40.50 @ 90 
A. With the Rule Astigmatism 
B. Lenticular Astigmatism 
C. Against the Rule Astigmat...
Which corneal layer controls the fluid content of the cornea? - ANSWER-endothelium 
 
What is cornea edema? - ANSWER-excess fluid in the stroma that can swell it and lead to loss of visual acuity 
 
What kind of contact lenses must be stabilized (not rotate) on the eye for good vision? - ANSWER-tori...
Voorbeeld 2 van de 9 pagina's
In winkelwagenWhich corneal layer controls the fluid content of the cornea? - ANSWER-endothelium 
 
What is cornea edema? - ANSWER-excess fluid in the stroma that can swell it and lead to loss of visual acuity 
 
What kind of contact lenses must be stabilized (not rotate) on the eye for good vision? - ANSWER-tori...
1x verkocht
What are the disadvantages of Soft Lenses? - ANSWER-Doesn't correct irregular astigmatism, favors deposit formation 
 
Which test measures the quantity of tears? - ANSWER-The Schirmer test. 
 
What are good results for the Schirmer test? - ANSWER-15 mm in 5 minutes. 
 
What are dry eye results for ...
Voorbeeld 2 van de 11 pagina's
In winkelwagenWhat are the disadvantages of Soft Lenses? - ANSWER-Doesn't correct irregular astigmatism, favors deposit formation 
 
Which test measures the quantity of tears? - ANSWER-The Schirmer test. 
 
What are good results for the Schirmer test? - ANSWER-15 mm in 5 minutes. 
 
What are dry eye results for ...
Which term refers to a sensitivity to light? 
A. Presbyopia 
B. Photophobia 
C. Pannus 
D. Ptosis - ANSWER-B. Photophobia 
 
The following is an example of what type of astigmatism? 
K's 42.50 @ 180 / 40.50 @ 90 
A. With-the-rule astigmatism 
B. Lenticular astigmatism 
C. Against-the-rule astigmati...
Voorbeeld 1 van de 4 pagina's
In winkelwagenWhich term refers to a sensitivity to light? 
A. Presbyopia 
B. Photophobia 
C. Pannus 
D. Ptosis - ANSWER-B. Photophobia 
 
The following is an example of what type of astigmatism? 
K's 42.50 @ 180 / 40.50 @ 90 
A. With-the-rule astigmatism 
B. Lenticular astigmatism 
C. Against-the-rule astigmati...
In against the rule astigmatism, the steepest corneal meridian: 
A. Is at or near 45 degrees 
B. Is at or near 90 degrees 
C. Is at or near 135 degrees 
D. Is at or near 180 degrees - ANSWER-D. Is at or near 180 degrees. 
 
The following RX represents: 
OD: +2.00 PSH= 20/20 
OS: -3.00-2.00x180 = 20...
Voorbeeld 2 van de 7 pagina's
In winkelwagenIn against the rule astigmatism, the steepest corneal meridian: 
A. Is at or near 45 degrees 
B. Is at or near 90 degrees 
C. Is at or near 135 degrees 
D. Is at or near 180 degrees - ANSWER-D. Is at or near 180 degrees. 
 
The following RX represents: 
OD: +2.00 PSH= 20/20 
OS: -3.00-2.00x180 = 20...
anterior chamber - ANSWER-the area bounded in front by the cornea and in the back by the lens and filled with aqueous 
 
aqueous - ANSWER-a clear, watery solution in the anterior and posterior chambers 
 
artery - ANSWER-the vessel supplying blood to the eye 
 
canal of schlemm - ANSWER-the passagew...
Voorbeeld 2 van de 7 pagina's
In winkelwagenanterior chamber - ANSWER-the area bounded in front by the cornea and in the back by the lens and filled with aqueous 
 
aqueous - ANSWER-a clear, watery solution in the anterior and posterior chambers 
 
artery - ANSWER-the vessel supplying blood to the eye 
 
canal of schlemm - ANSWER-the passagew...
antihistamines - ANSWER-are beneficial when treating allergies and cold symptoms because they dry out the mucous membranes of the nasal passage. However, this may also lead to dehydration of the tear film, they are also been known to slow down the blink rate and increase corneal sensitivity. 
 
agai...
Voorbeeld 1 van de 2 pagina's
In winkelwagenantihistamines - ANSWER-are beneficial when treating allergies and cold symptoms because they dry out the mucous membranes of the nasal passage. However, this may also lead to dehydration of the tear film, they are also been known to slow down the blink rate and increase corneal sensitivity. 
 
agai...
C. Loose lenses - ANSWER-Small puncuated stains on the corneal epithelium when seen under an ultraviolet light are most likely caused by: 
A. foreign bodies 
B. loose lenses 
C. tight lenses 
D. epical clearance lenses 
 
D. Too tight a lens - ANSWER-After about four hours of wear, your patient comp...
Voorbeeld 2 van de 5 pagina's
In winkelwagenC. Loose lenses - ANSWER-Small puncuated stains on the corneal epithelium when seen under an ultraviolet light are most likely caused by: 
A. foreign bodies 
B. loose lenses 
C. tight lenses 
D. epical clearance lenses 
 
D. Too tight a lens - ANSWER-After about four hours of wear, your patient comp...
Fluorescein is a valuable tool in evaluating the lens to cornea relationship of a rigid gas permeable lens. A special type of fluorescein (fluorosoft) should be used to evaluate the fitting relationship of a soft contact lens. 
 
If the diagnostic rigid gas permeable lens placed on the eye results i...
Voorbeeld 2 van de 15 pagina's
In winkelwagenFluorescein is a valuable tool in evaluating the lens to cornea relationship of a rigid gas permeable lens. A special type of fluorescein (fluorosoft) should be used to evaluate the fitting relationship of a soft contact lens. 
 
If the diagnostic rigid gas permeable lens placed on the eye results i...
The lipid layer functions primarily to: - ANSWER-prevent evaporation of the tear film 
 
The test which assesses the quantity of tears normally produced is: __________ - ANSWER-Schimmer 
 
The test which assesses the quality of the tear film is: _______ - ANSWER-BUT 
 
Prospective patients who fall ...
Voorbeeld 2 van de 5 pagina's
In winkelwagenThe lipid layer functions primarily to: - ANSWER-prevent evaporation of the tear film 
 
The test which assesses the quantity of tears normally produced is: __________ - ANSWER-Schimmer 
 
The test which assesses the quality of the tear film is: _______ - ANSWER-BUT 
 
Prospective patients who fall ...
The FDA classifies lens material by four groups as follows: - ANSWER-Group 1-low water < 50% water, non-ionic polymers (this group includes silicone hydrogel polymers) 
 
Group 2- high water > 50% water, non-ionic polymers 
 
Group 3- low water < 50% water, ionic polymers 
 
Group 4- hig...
Voorbeeld 2 van de 9 pagina's
In winkelwagenThe FDA classifies lens material by four groups as follows: - ANSWER-Group 1-low water < 50% water, non-ionic polymers (this group includes silicone hydrogel polymers) 
 
Group 2- high water > 50% water, non-ionic polymers 
 
Group 3- low water < 50% water, ionic polymers 
 
Group 4- hig...
Accommodation - ANSWER-The ability of the crystalline lens to adjust power to provide retinal focus of images of objects closer than optical infinity 
 
Aphakia - ANSWER-Absence of the crystalline lens. 
 
Astigmatism - ANSWER-A refractive defect where the refractive surface has different power in d...
Voorbeeld 2 van de 10 pagina's
In winkelwagenAccommodation - ANSWER-The ability of the crystalline lens to adjust power to provide retinal focus of images of objects closer than optical infinity 
 
Aphakia - ANSWER-Absence of the crystalline lens. 
 
Astigmatism - ANSWER-A refractive defect where the refractive surface has different power in d...
myopic eye - ANSWER-Eye is to long 
 
Hyperic eye - ANSWER-Eye is to short 
 
hyperopia - ANSWER-farsighted vision 
 
myopia - ANSWER-nearsighted 
 
emmetropia - ANSWER-normal vision 
 
Cornea Index - ANSWER-1.37 
 
Aqueous humor, viterious humor, water index - ANSWER-1.33 
 
Crystalline lens index ...
Voorbeeld 1 van de 1 pagina's
In winkelwagenmyopic eye - ANSWER-Eye is to long 
 
Hyperic eye - ANSWER-Eye is to short 
 
hyperopia - ANSWER-farsighted vision 
 
myopia - ANSWER-nearsighted 
 
emmetropia - ANSWER-normal vision 
 
Cornea Index - ANSWER-1.37 
 
Aqueous humor, viterious humor, water index - ANSWER-1.33 
 
Crystalline lens index ...
Adnexa Oculi - ANSWER-are the accessory structure that are considered part of the eye, but not part of the eyeball itself. these structures include: eyelids, eyelashes, tears, lacrimal apparatus, accessory glands and extrinsic muscles and orbit. everything outside of the eyeball. 
 
Meibomian Glands...
Voorbeeld 3 van de 29 pagina's
In winkelwagenAdnexa Oculi - ANSWER-are the accessory structure that are considered part of the eye, but not part of the eyeball itself. these structures include: eyelids, eyelashes, tears, lacrimal apparatus, accessory glands and extrinsic muscles and orbit. everything outside of the eyeball. 
 
Meibomian Glands...
Patient Selection - ANSWER-13-38yo; W>M; R.E +/-1.50D; K reading 41.00-46.00; Butʻs > 15 secs; Cornea with no significant and sequential staining, Good tear flow by Schrimer test, Regular corneas- no scarring or distortion of corneal mires, regular low astigmatism < +1.50, Good lid positio...
Voorbeeld 1 van de 3 pagina's
In winkelwagenPatient Selection - ANSWER-13-38yo; W>M; R.E +/-1.50D; K reading 41.00-46.00; Butʻs > 15 secs; Cornea with no significant and sequential staining, Good tear flow by Schrimer test, Regular corneas- no scarring or distortion of corneal mires, regular low astigmatism < +1.50, Good lid positio...
Diffuse corneal stippling observed during a 6 month follow up visit is most likely due to - ANSWER-posterior surface deposits 
 
A fluorescein pattern which shows a touch appearance in the horizontal meridian and a brighter green in the vertical meridian indicates that the patient has.. - ANSWER-Wit...
Voorbeeld 1 van de 2 pagina's
In winkelwagenDiffuse corneal stippling observed during a 6 month follow up visit is most likely due to - ANSWER-posterior surface deposits 
 
A fluorescein pattern which shows a touch appearance in the horizontal meridian and a brighter green in the vertical meridian indicates that the patient has.. - ANSWER-Wit...
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper IMORA. Stuvia faciliteert de betaling aan de verkoper.
Nee, je koopt alleen deze samenvatting voor $22.39. Je zit daarna nergens aan vast.
4,6 sterren op Google & Trustpilot (+1000 reviews)
Afgelopen 30 dagen zijn er 67096 samenvattingen verkocht
Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen