Mibi - Studienführer, Klassennotizen & Zusammenfassungen
Suchst du nach den besten Studienführern, Studiennotizen und Zusammenfassungen über Mibi? Auf dieser Seite findest du 42 Studienunterlagen zu Mibi.
Seite 3 aus 42 Ergebnisse
Sortieren nach
-
Updated NMTCB MOCK EXAM Qs & Ans
- Prüfung • 13 Seiten • 2024
-
- 10,45 €
- + erfahre mehr
A false positive In-111 WBC scan may be due to increased abdominal uptake in a patient: 
a. that is currently taking antibiotics 
b. with a sinus infection 
c. with a stomach ulcer 
d. with a renal cyst 
e. with cholecystitis - ANS B. Sinus Infection due to sinus drainage 
 
A patient receives 285uCi of I-123 NaI orally for a thyroid uptake study. Calculate the 24 hour percent uptake using the given data: 
Dose Count= 1425916 cpm 
Background= 88 cpm 
Patient counts= 193046 cpm 
Patient Backgrou...
-
NMTCB MOCK EXAM Questions(rated A)
- Prüfung • 13 Seiten • 2024
-
- 11,72 €
- + erfahre mehr
NMTCB MOCK EXAM Questions( 
A false positive In-111 WBC scan may be due to increased abdominal uptake in a patient: 
a. that is currently taking antibiotics 
b. with a sinus infection 
c. with a stomach ulcer 
d. with a renal cyst 
e. with cholecystitis - ANSWER B. Sinus Infection due to sinus drainage 
 
A patient receives 285uCi of I-123 NaI orally for a thyroid uptake study. Calculate the 24 hour percent uptake using the given data: 
Dose Count= 1425916 cpm 
Background= 88 cpm 
Patient counts...
-
NMTCB MOCK EXAM Questions and Answers| 2024 Update 100% Solved
- Prüfung • 12 Seiten • 2024
-
Im Paket-Deal erhältlich
-
- 11,23 €
- + erfahre mehr
NMTCB MOCK EXAM Questions 
and Answers| 2024 Update 100% 
Solved 
A false positive In-111 WBC scan may be due to increased abdominal uptake in a patient: 
a. that is currently taking antibiotics 
b. with a sinus infection 
c. with a stomach ulcer 
d. with a renal cyst 
e. with cholecystitis B. Sinus Infection due to sinus drainage 
A patient receives 285uCi of I-123 NaI orally for a thyroid uptake study. Calculate the 24 hour 
percent uptake using the given data: 
Dose Count= 1425916 cpm 
Bac...
-
NMTCB MOCK EXAM QUESTIONS WITH CORRECT ANSWERS
- Prüfung • 15 Seiten • 2024
-
Im Paket-Deal erhältlich
-
- 14,16 €
- + erfahre mehr
A false positive In-111 WBC scan may be due to increased abdominal uptake in a patient: 
a. that is currently taking antibiotics 
b. with a sinus infection 
c. with a stomach ulcer 
d. with a renal cyst 
e. with cholecystitis - Answer-B. Sinus Infection due to sinus drainage 
 
A patient receives 285uCi of I-123 NaI orally for a thyroid uptake study. Calculate the 24 hour percent uptake using the given data: 
Dose Count= 1425916 cpm 
Background= 88 cpm 
Patient counts= 193046 cpm 
Patient Backgr...
-
CRD Sonography Basics Exam
- Prüfung • 15 Seiten • 2023
-
Im Paket-Deal erhältlich
-
- 12,70 €
- + erfahre mehr
Done over two days 
Day 1 Resting images are taken after tracer injection 
 
Day 2 Blood vessels are opened mimicking stress and tracer is given correct answer: Cardiac Perfusion Imaging (MIBI) 
 
Nuclear test 
Aka nuclear ventriculography 
Measuring EF 
Uses SPECT correct answer: MUGA 
 
Using authority 
Collaboration 
Compromise 
Avoid correct answer: Strategies for conflict resolution 
 
Compassion 
Commitment to quality 
Respect for the individual correct answer: Sonography Canada Code...
Und so verdienst du zusätzliches Geld
-
NMTCB MOCK EXAM 2024 Qs&A
- Prüfung • 12 Seiten • 2024
-
Im Paket-Deal erhältlich
-
- 11,23 €
- + erfahre mehr
A false positive In-111 WBC scan may be due to increased abdominal uptake in a patient: 
a. that is currently taking antibiotics 
b. with a sinus infection 
c. with a stomach ulcer 
d. with a renal cyst 
e. with cholecystitis - B. Sinus Infection due to sinus drainage 
 
A patient receives 285uCi of I-123 NaI orally for a thyroid uptake study. Calculate the 24 hour percent uptake using the given data: 
Dose Count= 1425916 cpm 
Background= 88 cpm 
Patient counts= 193046 cpm 
Patient Background co...
-
Nuclear Medicine Board Review NMTCB Study Questions and Answers 2024
- Prüfung • 6 Seiten • 2024
-
Im Paket-Deal erhältlich
-
- 11,72 €
- + erfahre mehr
According to NRC criteria, which of the following is a misadministration? 
a. Infiltration of an attempted intravenous injection 
b. Administration of 10 mCi I-131 instead of the prescribed 9 mCi 
c. Administration of 20 mCi Tc-99m pertechnetate instead of the prescribed 10 mCi 
d. Administration of 15 mCi I-131 sodium iodide intravenously instead of orally as prescribed. 
e. Administration of 5 mCi Tc-99m sulfur colloid to the wrong patient. - D 
 
Chromatography testing of technetium radiophar...
-
Nuclear Medicine Board Review NMTCB Rated 100% Correct!!
- Prüfung • 6 Seiten • 2024
-
Im Paket-Deal erhältlich
-
- 10,74 €
- + erfahre mehr
According to NRC criteria, which of the following is a misadministration? 
a. Infiltration of an attempted intravenous injection 
b. Administration of 10 mCi I-131 instead of the prescribed 9 mCi 
c. Administration of 20 mCi Tc-99m pertechnetate instead of the prescribed 10 mCi 
d. Administration of 15 mCi I-131 sodium iodide intravenously instead of orally as prescribed. 
e. Administration of 5 mCi Tc-99m sulfur colloid to the wrong patient. - ANSWERD 
 
Chromatography testing of technetium rad...
-
NMTCB Sample Exam Questions with Verified Answers 2024 Top Graded
- Prüfung • 5 Seiten • 2024
-
Im Paket-Deal erhältlich
-
- 12,70 €
- + erfahre mehr
What is being evaluated with chromatography testing of technetium radiopharmaceuticals 
A. Aluminum Contamination 
B. Molybdenum Breakthrough 
C. Radionuclidic Purity 
D. Radiochemical Purity 
E. Chemical Purity - D. Radiochemical Purity 
 
The use of elliptical and or body counter orbits in SPECT imaging should result in improved 
A. Temporal Resolution 
B. Spatial Resolution 
C. Reconstruction Times 
D. Acquisition Times 
E. Patient Comfort - B. Spatial Resolution 
 
Which of the following v...
-
Nuclear Medicine Exam Questions with 100% Correct Answer
- Prüfung • 54 Seiten • 2024
-
Im Paket-Deal erhältlich
-
- 14,16 €
- + erfahre mehr
Nuclear Medicine Exam Questions with 
100% Correct Answer 
There are two points A and B. The distance between them is 30mm. Between both 
point are three pixels. What is the length of every single pixel? 
a.1 mm 
b.5 mm 
c.10 mm 
d.30 mm 
c 
Functional SPECT or PET of CNS can be used in the imaging of: 
a) Cerebral blood flow 
b) Brain regional metabolism 
c) Receptor distribution and density 
d) all of the above 
D 
What is the most likely effect of F-18 FDG? 
a.Anatomic 
b.Metabolic 
c.Physiol...
Wusstest du, dass ein Verkäufer auf Stuvia im Durchschnitt 76 € pro Monat mit dem Verkauf von Studienmaterial verdient? Hmm, Wink mit dem Zaunpfahl. Entdecke alles über Verdienstmöglichkeiten auf Stuvia