Which type of hose transports water from the pumping apparatus to the nozzle where it is applied to the fire? (541) - Attack hose A fire hose is labeled according to the: (541) - Size of its inside diameter Which type of hose is designed to connect the pumping apparatus to a pressurized water source, such as a hydrant? (542) - Large diameter soft sleeve hose Why is it advantageous for departments to use hose with national standard threaded couplings? (544) - Different departments that respond together can connect their hose sections without adapters A male hose coupling: (544) - Has the thread on the exterior The part of the coupling where it attaches to the hose is called the: (544) - Shank The _______ on a coupling is a flattened angle at the end of the threads that helps prevent crossthreading when connecting couplings. (544) - Higbee cut What is the purpose of lugs on a fire hose coupling? (545) - Aid in tightening and loosening connections Which type of lugs are shallow holes drilled into booster hose couplings that require a special spanner wrench to tighten? (545) - Recessed_lugs Which statement describes two-way couplings? (546) - Do not have male or female threads Which is characteristic of nonthreaded couplings? (546) - An adapter must be used to connect non threaded couplings to hydrantsAccording to NFPA 1962, fire hose should be service tested within 90 days before being placed in service for the first time and then: (547) - At least once a year Before fire hose and couplings are stored or placed back into service, they should be: (548) - Inspected for damage to the hose jacket and threads How should hard intake hose be cleaned after use? (548) - Rinse with clear water Woven-jacket fire hose: (548) - Must be brushed clear of dust and dirt after use In order to prevent mildew, _______ hose must be dried before being stored. (549) - Woven-jacket natural fiber What should be done to prevent damage when drying fire hose in hose towers or on racks? (549) - Secure the couplings to the rack or tower Hose that is stored in the fire apparatus bay: (550) - Must be inspected and cleaned more frequently due to exposure to oil, gasoline, and airborne contaminants To prevent damage to hose when storing it in racks, the hose should be: (551) - Rolled with the male

Meer zien Lees minder
Instelling
IFSTA 7th Edition - Chapter 12: Fire Hose
Vak
IFSTA 7th Edition - Chapter 12: Fire hose

Voorbeeld van de inhoud

IFSTA 7th Edition - Chapter 12: Fire hose Which type of hose transports water from the pumping apparatus to th e nozzle where it is applied to the fire? (541) - ✔✔Attack hose A fire hose is labeled according to the: (541) - ✔✔Size of its inside diameter Which type of hose is designed to connect the pumping apparatus to a pressurized water source, such as a hydran t? (542) - ✔✔Large diameter soft sleeve hose Why is it advantageous for departments to use hose with national standard threaded couplings? (544) - ✔✔Different departments that respond together can connect their hose sections without adapters A male hose coupling: (544) - ✔✔Has the thread on the exterior The part of the coupling where it attaches to the hose is called the: (544) - ✔✔Shank The _______ on a coupling is a flattened angle at the end of the threads that helps prevent cross -
threading when conn ecting couplings. (544) - ✔✔Higbee cut What is the purpose of lugs on a fire hose coupling? (545) - ✔✔Aid in tightening and loosening connections Which type of lugs are shallow holes drilled into booster hose couplings that require a special spanner wren ch to tighten? (545) - ✔✔Recessed_lugs Which statement describes two -way couplings? (546) - ✔✔Do not have male or female threads Which is characteristic of nonthreaded couplings? (546) - ✔✔An adapter must be used to connect non threaded couplings to hydrants

Geschreven voor

Instelling
IFSTA 7th Edition - Chapter 12: Fire hose
Vak
IFSTA 7th Edition - Chapter 12: Fire hose

Documentinformatie

Geüpload op
3 juli 2023
Aantal pagina's
4
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Brainarium Delaware State University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1879
Lid sinds
2 jaar
Aantal volgers
1044
Documenten
22653
Laatst verkocht
2 dagen geleden

3.8

324 beoordelingen

5
150
4
62
3
54
2
16
1
42

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen