Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien 4,6 TrustPilot
logo-home
Examen

NYC MASTER ELECTRICIAN EXAM ALREADY PASSED TEST | VERIFIED

Note
-
Vendu
-
Pages
41
Grade
A+
Publié le
19-01-2024
Écrit en
2023/2024

NYC MASTER ELECTRICIAN EXAM ALREADY PASSED TEST | VERIFIED Type ____ is multiconductor cable identified for use as underground service entrance cable. - ANSWER Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less - ANSWER Can be used only as isolating switch, shall not be opened under load Track lighting with outlets in a bathroom is not allowed because ? - ANSWER Track lighting has receptacle Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided with an on premise fuel supply sufficient for not less than ____ hours full demand operation of the system - ANSWER 6 hours Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. - ANSWER 30 Amps Where skin effect exist the ferromagnetic envelope shall be bonded at ____. - ANSWER Both ends GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. - ANSWER Locking The maximum voltage drop from service point to the last over-current device in a dwelling unit? - ANSWER 4% Which of the following statements best describe the grounding requirement for central vacuum outlet - ANSWER Accessible non current carrying metal parts are required to be connected to an equipment grounding conductor. In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system - ANSWER Are permitted Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or similar areas - ANSWER Do not include The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. - ANSWER Examined or treated Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____ duplex receptacles - ANSWER Single or two A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more patients - ANSWER Four Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment - ANSWER Listed fitting Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a different insulation temperature - ANSWER 3 inches Manufactured wiring systems constructed with type MC cable shall be supported and secured at intervals not exceeding ____ ft. - ANSWER 6 ft Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be identified with a ____ that shall be visible with the screw installed - ANSWER Green finish Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the window, cap, or other prominent part to distinguish them from fuses of higher ampere rating - ANSWER Hexagon The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts (volt-amperes) or the nameplate rating, which ever is larger, for each dryer served ? - ANSWER 5000 watts Service conductors installed as unjacketed multiconductor cable shall have a minimum clearance of ____ windows that are designed to be opened, doors, porches, stairs fire escape or similar locations. - ANSWER 3 ft (36 inches) —— Cartridge fuses of the renewable type shall be permitted to be used only for replacement in existing installation is where there is no evidence of over-fusing or tampering. - ANSWER Class H Branch circuit conductors within ____inches of the ballast shall have an insulation temperature rating not lower it 90°C 194°F - ANSWER 3" inches The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. - ANSWER 8 In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground plug ? - ANSWE

Montrer plus Lire moins
Établissement
NYC MASTER ELECTRICIAN
Cours
NYC MASTER ELECTRICIAN











Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
NYC MASTER ELECTRICIAN
Cours
NYC MASTER ELECTRICIAN

Infos sur le Document

Publié le
19 janvier 2024
Nombre de pages
41
Écrit en
2023/2024
Type
Examen
Contient
Questions et réponses

Sujets

$13.99
Accéder à l'intégralité du document:

Garantie de satisfaction à 100%
Disponible immédiatement après paiement
En ligne et en PDF
Tu n'es attaché à rien

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
stuviagenius18 Teachme2-tutor
Voir profil
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
322
Membre depuis
2 année
Nombre de followers
172
Documents
2876
Dernière vente
3 mois de cela
EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially; psychology,Nursing, Human resource Manageme

EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially; psychology,Nursing, Human resource Management and Mathemtics Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that\'s why i\'m one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work.

Lire la suite Lire moins
3.9

51 revues

5
24
4
11
3
9
2
3
1
4

Documents populaires

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions