Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

ASE A/C Exam Practice Questions and Answers

Rating
-
Sold
-
Pages
11
Grade
A+
Uploaded on
23-10-2024
Written in
2024/2025

ASE A/C Exam Practice Questions and Answers An EATC air conditioning system has low fan speed operation during high demand situations, like in direct sunlight. Technician A says this is because something is covering the sun load sensor's photo diode. Technician B says a sun load sensor is a variable resistor and can be tested with an ohmmeter. Who is correct? - Ans:-Both A and B A gurgling sound is heard coming from inside the dashboard of a vehicle. Technician A says this is air trapped in the heater core. Technician B says this noise can be caused by a blown head gasket. Who is correct? - Ans:-Both A and B A manifold gauge indicates a system has low discharge pressure. The MOST likely cause of this condition is: - Ans:-A damaged compressor reed valve. The compressor is rapidly cycling on and off on a CCOT (cycling clutch orifice tube) air conditioning system. Technician A says this condition can be caused by a low refrigerant charge. Technician B says this could be caused by a faulty clutch cycling switch. Who is correct? - Ans:-Both A and B ©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER 2024 Page 2/11 Technician A says while performing a retrofit from R-12 refrigerant to R134a refrigerant, the refrigerant must be recovered into a dedicated cylinder, they cannot be mixed. Technician B says R-12 refrigerant functions at higher pressures than R-134a refrigerant does. Who is correct? - Ans:-Tech A Technician A says an ambient temperature sensor senses cabin air temperature. Technician B says a faulty ambient temperature sensor can prevent compressor clutch engagement. Who is correct? - Ans:-Tech B During an initial inspection, the technician notices that one line on the receiver drier is cooler than the other. This is caused by: - Ans:-A restriction in the receiver drier. During a performance test on a CCOT system the manifold gauge indicates that the high side pressure is low and the low side pressure is high. This is caused by a: - Ans:-Faulty compressor An air conditioning system blows only warm air when the heater is on high output. Technician A says this could be a faulty heater control valve. Technician B says this could be caused by the cooling system's thermostat. Who is correct? - Ans:-Both A and B Technician A says a fixed orifice tube varies the flow of refrigerant in relation to temperature. Technician B says a fixed orifice tube is located between the condenser and the evaporator. Who is correct? - Ans:-B Only (A fixed orifice tube provides a consistent output, based upon the size of its orifice. It's a compromise between idle and highway conditions) ©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER 2024 Page 3/11 Technician A says the expansion valve is located on the inlet port of the evaporator. Technician B says the expansion valve's temperature sensing bulb is located near the outlet port of the evaporator. Who is correct? - Ans:-Both A and B During a visual inspection an oily spot is found on a hose leading from the compressor. Technician A says there may be a refrigerant leak in the system. Technician B says today's R134a systems use mineral oil instead of the older R12 compatible PAG oil. Who is correct? - Ans:-Tech A Only An air conditioning system contains a thermostatic expansion valve. The suction line leading to the compressor is cool to the touch. This indicates: - Ans:-Normal Condition All of these are true about an accumulator EXCEPT: - Ans:-This system contains a thermostatic expansion valve to meter the refrigerant. A vehicle has poor air conditioning performance. The customer has added R134a refrigerant to the system. Technician A says to use a refrigerant identifier. Technician B says refrigerant mixtures are not recommended, but will not affect system pressures. Who is correct? - Ans:-Tech A Only Two technicians are discussing a CCOT air conditioning system. Technician A says the system's pressure cycling clutch switch contains a bulb placed on the inlet port of the evaporator core. Technician B says a pressure cycling switch is located on the low side of the system. Who is correct? - Ans:-Tech B Only All these statements are true about a throttle position sensor EXCEPT: - Ans:-The ECM disengages

Show more Read less
Institution
ASE
Course
ASE

Content preview

©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED

FIRST PUBLISH OCTOBER 2024




ASE A/C Exam Practice Questions and
Answers

An EATC air conditioning system has low fan speed operation during high demand situations, like in

direct sunlight. Technician A says this is because something is covering the sun load sensor's photo

diode. Technician B says a sun load sensor is a variable resistor and can be tested with an ohmmeter.

Who is correct? - Ans:✔✔-Both A and B


A gurgling sound is heard coming from inside the dashboard of a vehicle. Technician A says this is air

trapped in the heater core. Technician B says this noise can be caused by a blown head gasket. Who is

correct? - Ans:✔✔-Both A and B


A manifold gauge indicates a system has low discharge pressure. The MOST likely cause of this condition

is: - Ans:✔✔-A damaged compressor reed valve.


The compressor is rapidly cycling on and off on a CCOT (cycling clutch orifice tube) air conditioning

system. Technician A says this condition can be caused by a low refrigerant charge. Technician B says this

could be caused by a faulty clutch cycling switch. Who is correct? - Ans:✔✔-Both A and B




Page 1/11

, ©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED

FIRST PUBLISH OCTOBER 2024




Technician A says while performing a retrofit from R-12 refrigerant to R134a refrigerant, the refrigerant

must be recovered into a dedicated cylinder, they cannot be mixed. Technician B says R-12 refrigerant

functions at higher pressures than R-134a refrigerant does. Who is correct? - Ans:✔✔-Tech A


Technician A says an ambient temperature sensor senses cabin air temperature. Technician B says a

faulty ambient temperature sensor can prevent compressor clutch engagement. Who is correct? -

Ans:✔✔-Tech B


During an initial inspection, the technician notices that one line on the receiver drier is cooler than the

other. This is caused by: - Ans:✔✔-A restriction in the receiver drier.


During a performance test on a CCOT system the manifold gauge indicates that the high side pressure is

low and the low side pressure is high. This is caused by a: - Ans:✔✔-Faulty compressor


An air conditioning system blows only warm air when the heater is on high output. Technician A says this

could be a faulty heater control valve. Technician B says this could be caused by the cooling system's

thermostat. Who is correct? - Ans:✔✔-Both A and B


Technician A says a fixed orifice tube varies the flow of refrigerant in relation to temperature. Technician

B says a fixed orifice tube is located between the condenser and the evaporator. Who is correct? -

Ans:✔✔-B Only (A fixed orifice tube provides a consistent output, based upon the size of its orifice. It's a

compromise between idle and highway conditions)




Page 2/11

Written for

Institution
ASE
Course
ASE

Document information

Uploaded on
October 23, 2024
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$10.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GraceAmelia West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
95
Member since
2 year
Number of followers
32
Documents
8974
Last sold
1 week ago
GraceAmelia\'s Emporium

Get a well Researched and Accurate Study Materials to Boost Your Grades and Excel Academically Offered by Seller Grace.

2.8

8 reviews

5
2
4
1
3
1
2
1
1
3

Trending documents

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions