FIRST PUBLISH OCTOBER 2024
ASE A/C Exam Practice Questions and
Answers
An EATC air conditioning system has low fan speed operation during high demand situations, like in
direct sunlight. Technician A says this is because something is covering the sun load sensor's photo
diode. Technician B says a sun load sensor is a variable resistor and can be tested with an ohmmeter.
Who is correct? - Ans:✔✔-Both A and B
A gurgling sound is heard coming from inside the dashboard of a vehicle. Technician A says this is air
trapped in the heater core. Technician B says this noise can be caused by a blown head gasket. Who is
correct? - Ans:✔✔-Both A and B
A manifold gauge indicates a system has low discharge pressure. The MOST likely cause of this condition
is: - Ans:✔✔-A damaged compressor reed valve.
The compressor is rapidly cycling on and off on a CCOT (cycling clutch orifice tube) air conditioning
system. Technician A says this condition can be caused by a low refrigerant charge. Technician B says this
could be caused by a faulty clutch cycling switch. Who is correct? - Ans:✔✔-Both A and B
Page 1/11
, ©GRACEAMELIA 2024/2025 ACADEMIC YEAR. ALL RIGHTS RESERVED
FIRST PUBLISH OCTOBER 2024
Technician A says while performing a retrofit from R-12 refrigerant to R134a refrigerant, the refrigerant
must be recovered into a dedicated cylinder, they cannot be mixed. Technician B says R-12 refrigerant
functions at higher pressures than R-134a refrigerant does. Who is correct? - Ans:✔✔-Tech A
Technician A says an ambient temperature sensor senses cabin air temperature. Technician B says a
faulty ambient temperature sensor can prevent compressor clutch engagement. Who is correct? -
Ans:✔✔-Tech B
During an initial inspection, the technician notices that one line on the receiver drier is cooler than the
other. This is caused by: - Ans:✔✔-A restriction in the receiver drier.
During a performance test on a CCOT system the manifold gauge indicates that the high side pressure is
low and the low side pressure is high. This is caused by a: - Ans:✔✔-Faulty compressor
An air conditioning system blows only warm air when the heater is on high output. Technician A says this
could be a faulty heater control valve. Technician B says this could be caused by the cooling system's
thermostat. Who is correct? - Ans:✔✔-Both A and B
Technician A says a fixed orifice tube varies the flow of refrigerant in relation to temperature. Technician
B says a fixed orifice tube is located between the condenser and the evaporator. Who is correct? -
Ans:✔✔-B Only (A fixed orifice tube provides a consistent output, based upon the size of its orifice. It's a
compromise between idle and highway conditions)
Page 2/11