NCCT|UPDATED&VERIFIED|100% SOLVED|GUARANTEED SUCCESS
While preparing to do an abdominal hysterectomy on a 500 pound female the surgical technologist begins to retrieve supplies and instrumentation. Which of the following retractor systems should the technologist retrieve for this case? Bookwalter An emaciated patient is scheduled for an abdominal hysterectomy with removal of excessive skin on bilateral thighs. The circulator has opted to place the ESU grounding pad on the patient's forearm. The surgical technologist should suggest that the ESU pad be removed and placed on the buttocks Which of the following are done during the initial count for a tubal ligation case? (Select the three (3) correct answers.) state the name of each item as you begin to count it, circulator records the items counted, count laps, Raytecs, needles, and blades The surgical technologist has just completed scrubbing for a repair of an abdominal aneurysm. The aneurysm repair ruptures during transport from the operating room bed to the stretcher. Which of the following actions should the surgical technologist take next? Don new gown and gloves. Which of the following is used to help maintain hemostasis intraoperatively in neurosurgery? raney clips Which of the following instruments should be passed to the surgeon to achieve hemostasis at the beginning of an operative procedure? (Select the three (3) correct answers.) electrosurgical pen, sponge, suction device The patient will need surgical skin prep for a right arm disarticulation at the shoulder. Which of the following is the correct method for completing this prep? Begin at shoulder to finger tips, including flank and chest, prepping the axilla last, using as many sponges as needed, keeping the arm away from the bed. When disinfecting a flexible endoscope used on a patient with TB, which of the following sterilization methods should be employed? steris During a total hip replacement, how can a surgical technologist prevent blood from drying on instruments? Place the instruments in a basin of sterile water. Which of the following prep solutions is contraindicated for use with a laser? Duraprep In the Sterile Processing Department, a DART test for autoclave steam sterilizers should be run daily. Upon opening a sterilized instrument tray, the surgical technologist finds bioburden inside the lumen of a metal suction. Which of the following actions should the surgical technologist take? Remove the sterilized instrument tray from the sterile field. The surgeon requests a non-absorbable suture for skin closure. Which of the following sutures is non-absorbable? Nylon The anesthesia provider would typically ask the surgical technologist how much fluid has been used in order to estimate blood loss. Postoperatively a hernia repair patient complains of ulnar pain, numbness and tingling bilaterally. The most likely cause of the patient's discomfort is that the surgical technologist forgot to place arm pads. The surgical technologist must discard a malfunctioning sterilant and replace with a new one. Where should the technologist look to find the proper disposal protocol for this product? hospital MSDS log When steam sterilizing biological indicators, how long are they incubated before the reading is recorded? 24 hours Ten minutes into an automatic chemical washer cycle for an instrument string, the surgical technologist notices she has missed a few critical instruments. Which of the following should the technologist do? Wait until the washer stops and run a new cycle with the instruments. During an otorhinolaryngologic procedure, which of the following precautions should the surgical technologist take if the anesthesia provider is using an uncuffed endotracheal tube? Moisten sponges and place around the field prior to start of procedure to minimize leakage and reduce heat buildup. Which of the following should the surgical technologist do immediately before connecting the Jackson-Pratt drain to the drainage tubing? Squeeze the bulb to apply manual suction. Prior to a case the surgical technologist determines the power saw is not functioning. Which of the following is the most likely cause? The battery has not been adequately charged. The surgical technologist places the patient in Fowler position with head secured by craniotomy headrest. Which of the following locations indicates correct application of the safety strap? 2 inches above the knees Which of the following is the minimum number of counts for a Cesarean section case? four At the end of each case the surgical technologist should rinse blood from the instruments with sterile water. When breaking down the setup, which of the following steps should be completed first? All sharps are contained and disposed of in the sharps container. Which of the following retractors will the surgical technologist need for an emergent bring back case on a 450 lb abdominal hysterectomy patient? bookwalter The surgical team has just completed a radical mastectomy and the surgeon has left the room. While cleaning up the back table the surgical technologist notices the Jackson Pratt placed during this surgery is full with bright red fluid. Which of the following should the surgical technologist do next? Inform the circulator that the drain is full and there is the potential for active bleeding in the surgical site. The surgeon is doing a laparoscopic procedure using an endo GIA stapler. He passes the stapler to the surgical technologist and asks him to reload. Which of the following should the technologist do to the stapler before passing back to the surgeon? Close the jaws. When a surgical technologist is being relieved at end of shift during a myomectomy, she is required to conduct a complete count. While preparing the room for a surgical procedure using the laser, which of the following policies ensure the laser is being used correctly? (Select the three (3) correct answers.) Post warning signs outside the room., Do not use alcohol based preps., Wear safety goggles. When donning a sterile gown the surgical technologist should keep the inside of the gown toward the body. After a tracheostomy procedure the surgical technologist should keep which of the following items sterile on the back table until the patient leaves the room? tracheostomy hook and spreader At the beginning of a carpal tunnel procedure the surgeon announces that he will use a Steven's scissor for every hand case he does from this day forward. After the case, which of the following is the most efficient way to make sure he has his Steven's scissor moving forward? Add the Steven's scissor to every hand procedure preference card for the surgeon. Patient skin preparation for LAVH and abdominal to perineal procedures should be performed using which of the following solutions? iodophor paint Following an eyelid laceration repair, the surgeon begins to close the skin. Anticipating the surgeon's needs the surgical technologist should hand the surgeon steri strips. The surgical team prepares the room for a trauma case. The nurse is notified by the ER that the patient is a 3-year-old female with a gunshot wound. In preparing the room for the patient's arrival, the surgical technologist should ensure that the room is is maintained at 75 degrees F (23 C). A surgical technologist working the night shift is preparing implants for the next morning. After running the autoclave, the cycle fails. Which of the following should the surgical technologist do? Unwrap, decontaminate and re-sterilize implants with a biological test pack and place a hold on the use of the sets until the BI test results are available.
Written for
- Institution
- NCCT
- Module
- NCCT
Document information
- Uploaded on
- July 25, 2023
- Number of pages
- 32
- Written in
- 2022/2023
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
ncct|updatedampverified|100 solved|guaranteed succe
Also available in package deal