Journeyman practice test 2024 with complete verified solutions.
  • Journeyman practice test 2024 with complete verified solutions.

  • Exam (elaborations) • 16 pages • 2024
  • Available in package deal
  • There are six conductors in a raceway connected to 75° rated breakers. Each wire has a 70-amp load using THHN conductors. The minimum size conductor used are #__________ AWG. a. 4 b. 6 c. 8 d. 10 a Thermal insulation shall not be installed within __________ inch(es) of recessed fixtures. a. 1⁄2 b. 3⁄4 c. 2 d. 3 d Brainpower Read More A 1-inch conduit contains three 3-wire circuits. All conductors are #10 TW. Each circuit consist of two phase conductors, one gro...
    (0)
  • $14.99
  • + learn more
Industrial Red Seal Practice Exam Questions and Answers Already Passed
  • Industrial Red Seal Practice Exam Questions and Answers Already Passed

  • Exam (elaborations) • 33 pages • 2023
  • Available in package deal
  • Industrial Red Seal Practice Exam Questions and Answers Already Passed NB: Answers appear before each question and are highlighted in yellow. B Which meter will be damaged when used on an energized circuit? A) A wattmeter. B) An ohmmeter. C) An ammeter. D) A voltmeter. D The open circuit voltage of a lead acid battery is 39 Volts, and the terminal voltage is 35 Volts when connected to a 141 Amp load. What is the internal resistance of the battery? A) 4.0 ohms. B) 1.7 ohms. C) 0.283 ohms. D)...
    (0)
  • $10.99
  • + learn more
Master Electrician (First Set 1-85) with Complete Solutions!
  • Master Electrician (First Set 1-85) with Complete Solutions!

  • Exam (elaborations) • 8 pages • 2024
  • Available in package deal
  • A 150 kVA service transformer has a 480Y/277 volt 3-phase primary and a 208Y/120 volt, 3-phase secondary. What is the approximate full-load ampere rating of the primary of the transformer? - ANSWER-180 amperes Where a conductor is marked RHW-2 on the insulation what does the "-2" represent? - ANSWER-The conductor has a maximum operating temperate of 90 degrees C. For a grounded electrical system supplied by a feeder or branch circuit, the equipment grounding conductor shall be sized in a...
    (0)
  • $11.99
  • + learn more
Master Electrician (First Set 1-85) with Complete Solutions
  • Master Electrician (First Set 1-85) with Complete Solutions

  • Exam (elaborations) • 8 pages • 2024
  • A 150 kVA service transformer has a 480Y/277 volt 3-phase primary and a 208Y/120 volt, 3-phase secondary. What is the approximate full-load ampere rating of the primary of the transformer? - ANSWER-180 amperes Where a conductor is marked RHW-2 on the insulation what does the "-2" represent? - ANSWER-The conductor has a maximum operating temperate of 90 degrees C. For a grounded electrical system supplied by a feeder or branch circuit, the equipment grounding conductor shall be sized in a...
    (0)
  • $12.49
  • + learn more
MASTER ELECTRICIAN REAL TEST  QUESTIONS ANSWERED CORRECTLY
  • MASTER ELECTRICIAN REAL TEST QUESTIONS ANSWERED CORRECTLY

  • Exam (elaborations) • 16 pages • 2024
  • Available in package deal
  • MASTER ELECTRICIAN REAL TEST QUESTIONS ANSWERED CORRECTLY Given: Two separate Services are identical in voltage and amperage, except that one service serves only motor - loads and the other serves lighting loads only. in the event of a short circuit in these services, the available short circuit current will be: A) The same in either service B) Higher in the motor-load service C) Higher in the lighting -load service D) 25% greater in the service for the motor load - ANSWER The s...
    (0)
  • $12.49
  • + learn more
Master Electrician 2 PRESET PREP TEST FOR  REVISION Q&A VERIFIED
  • Master Electrician 2 PRESET PREP TEST FOR REVISION Q&A VERIFIED

  • Exam (elaborations) • 9 pages • 2023
  • Available in package deal
  • Master Electrician 2 PRESET PREP TEST FOR REVISION Q&A VERIFIED In dwelling units and guest rooms of hotels and motels, overcurrent protection devices shall NOT be located in _____. - ANSWER bathrooms The conductors in multiconductor portable cables, of over 600 volts nominal, used to connect mobile equipment and machinery, shall be at least size _____ copper or larger and employ flexible stranding. - ANSWER 12 AWG Where a flat cable assembly, Type FC, is installed LESS than ___...
    (0)
  • $9.99
  • + learn more
HVAC Level 1 Module 3 Electricity Questions with Corrects A+
  • HVAC Level 1 Module 3 Electricity Questions with Corrects A+

  • Exam (elaborations) • 5 pages • 2024
  • Available in package deal
  • Electrons flow from __________ to ____________. - negative, postitive What is the better conductor of electricity? Copper, Gold, oil, or aluminum - gold One horsepower equals ____________. - 746 watts Transformers are used to lower voltages because very _____ voltages can be transmitted easier and cheaper than 240 volts. - high High voltage is defined as above ____ volts. - 600 Effective voltage is defined as what percent of peak voltage? - 70.7% Formula to fi...
    (0)
  • $10.99
  • + learn more
NICET Prep: Fire Alarms Exam Questions Correctly Answered.
  • NICET Prep: Fire Alarms Exam Questions Correctly Answered.

  • Exam (elaborations) • 18 pages • 2024
  • Available in package deal
  • NICET Prep: Fire Alarms Exam Questions Correctly Answered. Assembly Occupancy's are buildings used for gathering of _____ or more people for deliberation, worship, entertainment, eating, drinking, amusement, awaiting transportation or similar. - CORRECT ANSWER 50 people Class 3 wiring installed under roof decking is required to be at least __ inches below the roof decking - CORRECT ANSWER 1.5 Inches The minimum length of free conductors at outlet boxes is - CORRECT ANSWER 6 Inches ...
    (0)
  • $11.49
  • + learn more
Master Electrician 2
  • Master Electrician 2

  • Exam (elaborations) • 6 pages • 2023
  • In dwelling units and guest rooms of hotels and motels, overcurrent protection devices shall NOT be located in _____. - Answer- bathrooms The conductors in multiconductor portable cables, of over 600 volts nominal, used to connect mobile equipment and machinery, shall be at least size _____ copper or larger and employ flexible stranding. - Answer- 12 AWG Where located in Class I, Division 1 locations, transformers containing oil or a liquid that will burn shall be _____. - Answer- installe...
    (0)
  • $10.99
  • + learn more
MASTER ELECTRICIAN REAL TEST  QUESTIONS ANSWERED CORRECTLY
  • MASTER ELECTRICIAN REAL TEST QUESTIONS ANSWERED CORRECTLY

  • Exam (elaborations) • 16 pages • 2024
  • Available in package deal
  • MASTER ELECTRICIAN REAL TEST QUESTIONS ANSWERED CORRECTLY Given: Two separate Services are identical in voltage and amperage, except that one service serves only motor - loads and the other serves lighting loads only. in the event of a short circuit in these services, the available short circuit current will be: A) The same in either service B) Higher in the motor-load service C) Higher in the lighting -load service D) 25% greater in the service for the motor load - ANSWER The s...
    (0)
  • $13.49
  • + learn more