What does PLFA stand for? - Answer- Power Limited Fire Alarm 
 
What does NPLFA stand for? - Answer- Non Power Limited Fire Alarm 
 
What material must NPLFA circuit conductors be made from - Answer- Only solid or stranded copper is permitted 
 
What is a single station detector? - Answer- Battery powered smoke detectors that do not communicate off premises. 
 
What is a multiple station detector? - Answer- Mains powered smoke detectors with battery backup that are linked together, so that if on...
-
Residential Wireman Electrical Exam - Larry Bobo(GRADED A)
- Exam (elaborations) • 15 pages • 2024
-
- $12.99
- + learn more
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper 
 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 - ANSWER 4 
 
The continuity of the grounded conductor shall depend on a busbar or __ only. 
 
Continuity, Grounded conductors 
200.12 - ANSWER wire. 
 
Each multi-wire branch circuit shall be provided with...
-
Residential Wireman Electrical Exam questions with correct answers
- Exam (elaborations) • 18 pages • 2023
- Available in package deal
-
- $14.99
- + learn more
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper 
 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 CORRECT ANSWER 4 
 
The continuity of the grounded conductor shall depend on a busbar or __ only. 
 
Continuity, Grounded conductors 
200.12 CORRECT ANSWER wire. 
 
Each multi-wire branch circuit shall be p...
-
Residential Wireman Electrical Exam - Larry Bobo Questions And Answers Rated A+
- Exam (elaborations) • 15 pages • 2024
- Available in package deal
-
- $7.49
- + learn more
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase 
underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG 
copper to 1 AWG copper is __ AWG copper 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 - Answer-4 
The continuity of the grounded conductor shall depend on a busbar or __ only. 
Continuity, Grounded conductors 
200.12 - Answer-wire. 
Each multi-wire branch circuit shall be provided with a means t...
-
TFM 12 FIRE ALARM TECHNICAL EXAM 2024 WITH 100% CORRECT ANSWERS
- Exam (elaborations) • 10 pages • 2024
-
- $17.49
- + learn more
Does a fire hood system and a kitchen need to be monitored by the fire alarm system? Answer - Yes 
 
What does PLFA stand for? Answer - Power Limited Fire Alarm 
 
What does NPLFA stand for? Answer - Non-Power Limited Fire Alarm 
 
What is the difference between PFLA and NPFLA? Answer - an NPLFA can operate at up to 600v, and the power output isn't limited 
 
a PLFA has the voltage and power limited by a listed power source. 
 
What material must NPFLA circuit conductors be made from? Answer - ...
Make study stress less painful
-
NFPA 72 Questions and Answers with Certified Solutions
- Exam (elaborations) • 17 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
NFPA 72 Questions and Answers with 
 
Certified Solutions 
 
What does PFLA stand for? Power Limited Fire Alarm. 
 
What does NPFLA stand for? Non-Power Limited Fire Alarm. 
 
What material must NPFLA circuit conductors be made from? Only solid or stranded copper 
is permitted. 
 
What is a single station detector? Battery powered smoke detectors that do not communicate 
off premises. 
 
What is a multiple station detector? Mains powered smoke detectors with battery backup that 
are linked toget...
-
Electrical Code Calculations lvl 1 Lesson 1 Midterm Exam With Correct Solutions.
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $9.49
- + learn more
The term ampacity is defined as the ? current, in ampheres, that a conductor can carry continuously under conditions of use without exceeding its temperature rating. - Answer Maximum 
 
A conductor's ampacity is directly related to the type of insulation used on the conductor. - Answer True 
 
The voltage rating of conductors covered by Table 310.16 is up to and including ? - Answer 2,000 V 
 
Table 310.16 can be used when there are not more than ? single insulated current-carrying con...
-
TFM 12 FIRE ALARM TECHNICAL EXAM 2024 WITH ACCURATE SOLUTIONS
- Exam (elaborations) • 10 pages • 2024
-
- $14.49
- + learn more
TFM 12 FIRE ALARM TECHNICAL EXAM 2024 WITH ACCURATE SOLUTIONS 
 
 
Does a fire hood system and a kitchen need to be monitored by the fire alarm system? Answer - Yes 
 
What does PLFA stand for? Answer - Power Limited Fire Alarm 
 
What does NPLFA stand for? Answer - Non-Power Limited Fire Alarm 
 
What is the difference between PFLA and NPFLA? Answer - an NPLFA can operate at up to 600v, and the power output isn't limited 
 
a PLFA has the voltage and power limited by a listed power source. 
 
...
-
Fire Alarm TFM 12 Exam Review
- Exam (elaborations) • 14 pages • 2024
-
- $9.99
- + learn more
Fire Alarm TFM 12 Exam Review 
 
What does PLFA stand for? - Power Limited Fire Alarm 
 
What does NPLFA stand for? - Non Power Limited Fire Alarm 
 
What material must NPLFA circuit conductors be made from - Only solid or stranded copper 
is permitted 
 
What is a single station detector? - Battery powered smoke detectors that do not 
communicate off premises. 
 
What is a multiple station detector? - Mains powered smoke detectors with battery backup 
that are linked together, so that if one un...
-
Texas Fire Alarm Exam Questions With Answers
- Exam (elaborations) • 6 pages • 2024
-
- $8.99
- + learn more
Texas Fire Alarm Exam Questions With Answers 
 
What does PLFA stand for? - Answer -Power Limited Fire Alarm 
 
What does NPLFA stand for? - Answer -Non-Power Limited Fire Alarm 
 
What material must NPLFA circuit conductors be made from? - Answer -Only solid or stranded copper is permitted. 
 
What is a single station detector? - Answer -Battery powered smoke detectors that do not communicate off premises. 
 
What is a multiple station detector? - Answer -Mains powered smoke detectors with batt...
Study stress? For sellers on Stuvia, these are actually golden times. KA-CHING! Earn from your study resources too and start uploading now. Discover all about earning on Stuvia