When testing a water level supervisory switch serving a pressure tank a signal shall indicate if
the water level _____________from the required level
(NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS - rises or falls over 3 inches
If combination audible/visible appliances are installed the location of t...
nicet level 1 study guide questions | 150 questions with 100 correct answers | updated amp verified
Geschreven voor
Nicet Level 1
Nicet Level 1
1
beoordeling
Door: gabebmesa • 1 jaar geleden
Verkoper
Volgen
Tulloch
Ontvangen beoordelingen
Voorbeeld van de inhoud
Nicet Level 1 Study Guide Questions When testing a water level supervisory switch serving a pressu re tank a signal shall indicate if the water level _____________from the required level (NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS - rises or falls over 3 inches If combination audible/visible appliances are installed the location of the installed applian ce shall be determined by the requirements of _______. (Nfpa 72 18.4.8.1) - ANS - the visible appliance What is the maximum number of 12 gauge THHN wires that can be installed in 1" EMT? (Nec Annex C tables) - ANS - 26 Two resistors are connected in pa rallel. R1 = 300 Ohms, R2 = 300 Ohms. What is their equivalent resistance? - ANS - 150 ohms A Room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A spot type heat detector has been selected that is listed for a 50' maximum spacing between detectors. According to NFPA 72 how many detectors will be needed to protect this room? x = - ANS - 12 According to NFPA 72 the minimum number of restorable fixed temperature spot type heat detectors that must be tested during e ach annual test is? (NFPA 72 14.4.4.5.1) - ANS - Two detectors or more on each initiating device circuit According to NFPA 72 how many spot type heat detectors are required for a space that is 80' long and 55 floor wide with a smooth 10' ceiling? the detector is listed for a maximum space between detectors of 30' - ANS - 6 What color code requirement for a s pot type heat detector rated at 200 ゚F - ANS - White (NFPA 72, Table 17.6.2.1) Unless otherwise recommended by the manufacturers published instructions single and multiple stations smoke alarms installed in one and 2 family dwellings shall be replaced ever y - ANS - 10 years from the day -of manufacture. (NFPA 72, 14.4.7.1) Fire alarm cables are permitted to be strapped to conduit to support the cable - ANS - False (NEC 760.143) Where non power limited wiring is installed exposed it must be mechanically pro tected within_____of the finished floor - ANS - 7' ft Fire-Warning equipment to be installed in residential occupancies shall produce the audible emergency evacuation signal described in - ANS - ANSI S3.41 According to NFPA 72, visible notification appli ance for non -sleeping areas must be mounted between ___ and ___ inches above the finished floor - ANS - 80 & 96 If system impairment occurs, the owner must be notified ___ within ___ - ANS - in writing & within 24 hours A 20 X 20' ft room with a 20'ft hi gh ceiling requires at a minimum a ___ ceiling mounted strobe - ANS - 30 candela According to NFPA 72, a 40 x 40'ft room or area with a 10'ft ceiling is best covered by a ___ cd visible notification appliance, centered on one wall. - ANS - 60 Conductors returning to the fire alarm control panel (FACP) from the last field device on the circuit might indicate a _____ circuit - ANS - Class A Secondary power supplies for an emergency voice/alarm communication fire alarm system shall be capable of operating f or minimum of ___ of standby followed by ___ of alarm. - ANS - 24 hrs & 15 mins The fire alarm system primary power branch circuit disconnecting means must be ___ in color. - ANS - Red The secondary power supply for protected premises shall automatically provide power within ___ seconds when primary power fails. - ANS - 10 seconds Under which of the following conditions shall spot -type smoke detectors NOT be installed? - ANS - When the temperature is over 100*F Who is responsible for maintaining Personal Protective Equipment? - ANS - YOU, the employee What does GFCI stand for ? - ANS - Ground Fault Circuit Interrupter A fixed -temperature, non -restorable spot type heat detector shall be tested ____ from initial installation. - ANS - 15 years after Heat detectors should be selected to operate at least ___ degrees Farenheit above the maximum expected ambient temperature at the ceiling of the protected space. - ANS - 20*F According to the NFPA 72, testing records of the fire alarm system shall be kept until the next test and ____ year thereafter. - ANS - 1 Who is responsible for storing and maintaining testing records of the fire alarm system? - ANS - The Owner of the system
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
√ Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Tulloch. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €14,69. Je zit daarna nergens aan vast.