100% tevredenheidsgarantie Direct beschikbaar na betaling Zowel online als in PDF Je zit nergens aan vast
logo-home
NMTCB Practice Exam - New book Nuclear Medicine Technology - Review Questions for the Board Examinations 5th ed. Mantel, Reddin, Cheng, Alavi | RATED A+ €10,28   In winkelwagen

Tentamen (uitwerkingen)

NMTCB Practice Exam - New book Nuclear Medicine Technology - Review Questions for the Board Examinations 5th ed. Mantel, Reddin, Cheng, Alavi | RATED A+

 17 keer bekeken  0 keer verkocht
  • Vak
  • NMTCB
  • Instelling
  • NMTCB

NMTCB Practice Exam - New book Nuclear Medicine Technology - Review Questions for the Board Examinations 5th ed. Mantel, Reddin, Cheng, Alavi | RATED A+

Voorbeeld 2 van de 15  pagina's

  • 2 januari 2024
  • 15
  • 2023/2024
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • NMTCB
  • NMTCB
avatar-seller
NMTCB Practice Exam - New book Nuclear Medicine Technology - Review Questions for the Board Examinations 5th ed. Mantel, Reddin, Cheng, Alav i | RATED A+ In which RP is Tc99m left in the valence state of +7 a. sulfur colloid b. MAA c. MAG3 d. sestamibi - A. Sulfur colloid a tech receives a request for a patient to receive Sm153 for palliation of pain from bone mets. the patient has a WBC count of 3500 and 40000 platelets. what should happen next? a. the order should be changed to Sr89 b. the tx should be delayed until the platelet ct is at least 60,000 c. the tx should be delayed until the WBC is below 2400 d. the Sm153 should be ordered - B. the tx should be delayed until the platelet ct is at least 60,000 a SC kit requires the addition of 1 -3 ml containing no more than 500mCi of TcO4 -. in addition, 1.5 ml of solution A must be added before boiling, and 1.5 ml of Solution B must be added after cooling. If the kit is correctly prepared, what is the max concentration of Tc99m it could contain? a. 83 mCi/ml b. 125 mCi/ml c. 167 mCi/ml d. 500 mCi/ml - B. 125 mCi/ml max. 1 ml TcO4 - containing 500 mCi 500/(1.5+1.5+1) = 125 mCi/ml A hine -duley phantom is useful for testing the spatial resolution and spatial linearity with only one image. a. true b. false - B. false the advantage of a lung ventilation scan performed with Xenon is a. the ability to match perfusion and vent positioni ng b. the ability to detect delayed washout c. the ability to perform the exam at the patient's bedside d. the ability to perform perfusion before ventilation without increasing the dose given for the vent study - B. the ability to detect delayed washout A diphosphonate kit contian 180 mCi of Tc99m in 30 ml when it is prepared at 8am. Immediately, a 20 mCi dose is withdrawn for a bone scan. if the patient arrives late at 9:30 and half the volume is accidentally discharged, how much volume from the kit must now be added to the syringe to correct the dose to 20 mCi? (no other doses have been withdrawn meanwhile, and the decay factor for 1.5 hrs is 0.841) a. 1.5 ml b. 2.0 ml c. 2.3 ml d. 2.5 ml e. 2.7 ml - C. 2.3 mL lots of math, sorry :( a WBS bone scan fil m shows a good posterior image, but the anterior view appears diffuse with greater soft tissue activity. what is the probable cause? a. wrong collimator used for anterior b. increased patient to detector distance on the ant relative to the post c. low tagg ing efficiency of the RP d. patient was not sufficiently hydrated e. none of the above - b. increased patient to detector distance on the ant relative to the post Which of the following will not reduce the probability of contamination from perspiration and saliva of a therapy patient? a. disposable eating utensils b. plastic covering over the mattress c. covering the phone receiver with plastic d. collecting the pat ient's waste and storing until decayed to background - d. collecting the patient's waste and storing until decayed to background bone marrow imaging is performed using: a. MDP b. HDP c. sulfur colloid d. Gd153 e. A and B - C. sulfur colloid why would an image of the brain be obtained during a lung perfusion scan using Tc99m MAA? a. rule out brain mets b. to detect low tagging efficiency c. to detect a R -L cardiac shunt

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

√  	Verzekerd van kwaliteit door reviews

√ Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper STUVATE. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €10,28. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 67096 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€10,28
  • (0)
  Kopen