S12 Sprinkler Chart | 134 Questions and Answers 100% Correct | New Update 2024 How often shall the stem of an OS&Y Valve be lubricated - Answer Annually The 3 year dry pipe trip test is to be performed by whom? - Answer MP & MFSPC Fire department connections are to be inspected how often? - Answer Quarterly Water motor gongs are to be tested how often? - Answer Quarterly In a water spray fixed system inspection if the strainer is found corroded what color tag is required? - Answer Yellow A sprinkler head with a red frame has a temperature classification of? - Answer Extra High (325 - 375°F) The Hydraulic name plate shall be inspected how often? - Answer Quarterly What color tag is required when sprinkler heads are found to be lightly corroded? - Answer Orange Obstructions in sprinkler systems shall be investigated how often? - Answer 5 Years What color tag is required when the circuit breakers on a special service pump are over 2 years old? - Answer Orange What color tag is required when sprinkler heads made prior to 1920 have not been replaced? - Answer Orange, notify FDNY after 30 days During an operational test of a foam water sprinkler system, if the nozzles are plugged what color tag is used? - Answer Red Steel water storage tanks without corrosive protection are to be inspected how often? - Answer 3 years A sprinkler head with a white frame has a temperature rating of? - Answer 175 - 225°F The weekly test of an electric fire pump is how long? - Answer 10 minutes The weekly test of a Diesel fire pump is how long? - Answer 30 minutes Upon inspection of a sprinkler system, if the hydraulic nameplate is missing what color tag is used? - Answer Yellow When inspecting a preaction system, if the electrical components are not in service what color tag is used? - Answer Red Vane type water flow devices shall be tested how often? - Answer Semi -
annually Proper number of spare heads and wrenches shall be inspected how often? - Answer Annually The temperature rating of a sprinkler head with a green glass bulb is? - Answer 175 - 225°F When inspecting a sprinkler system if the spare sprinkler cabinet is missing what color tag should be used? - Answer Yellow On a dry pipe sprinkler head if no tests were conducted in 12 years what color tag should be used? - Answer Orange Red Tag - Answer Impairment (Notify FDNY , shall be fixed immediately) Orange Tag - Answer Critical Deficiency (Notify FDNY if not fixed after 30 days)
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
√ Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper StudySet. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €12,30. Je zit daarna nergens aan vast.