100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten
logo-home
Complete Test Bank Radiographic Image Analysis 5th Edition Martensen Questions & Answers with rationales (Chapter 1-12) €19,57
In winkelwagen

Tentamen (uitwerkingen)

Complete Test Bank Radiographic Image Analysis 5th Edition Martensen Questions & Answers with rationales (Chapter 1-12)

1 beoordeling
 8 keer verkocht
  • Vak
  • NURSING
  • Instelling
  • NURSING
  • Boek

Radiographic Image Analysis 5th Edition Martensen Test Bank Complete Test Bank Radiographic Image Analysis 5th Edition Martensen Questions & Answers with rationales (Chapter 1-12) PDF File All Pages All Chapters Grade A+ GRADEXAM This is NOT a book! This is a Test Bank (Study Questions) to help ...

[Meer zien]

Voorbeeld 4 van de 131  pagina's

  • 17 februari 2024
  • 131
  • 2023/2024
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • NURSING
  • NURSING

1  beoordeling

review-writer-avatar

Door: alirezasalehivaziri • 7 maanden geleden

avatar-seller
Test Bank for Radiographic Image
Analysis 5th Edition Martensen Chapter 1
- 12 Updated Guide 2022




If you need any other Test Banks or eTextbooks contact us:

,Radiographic Image Analysis 5th Edition Martensen
Test Bank
Chapter 01: Guidelines for Image Analysis
Martensen: Radiographic Image Analysis, 5th Edition
MULTIPLE CHOICE

1. The patient demographic requirements for radiographic images include all of the following
except
a. patient and facility identification.
b. time and date.
c. birth date.
d. technologist’s identification.

ANS: D

2. Which of the following is true about image markers?
1. They are radiopaque.
2. They should be reversed before being placed on the IR.
3. They should be positioned as close to the median plane as possible.
4. They will be magnified if positioned on the imaging table or patient.
a. 1 only
b. 1 and 4 only
c. 2 and 3 only
d. 4 only
ANS: B

3. What is the marker placemenN foR
tU heIpNrG
r tS ecB
ojT tio.nCoO
fM
lateral vertebrae?
a. Laterally on the side being identified
b. Anteriorly, identifying the side positioned closer to the IR
c. Anywhere within exposure field
d. Laterally, identifying the side situated closer to the IR

ANS: B

4. What is the marker placement for the projection of PA cranium?
a. Laterally on the side being identified
b. Anteriorly, identifying the side positioned closer to the IR
c. Anywhere within the exposure field
d. Laterally, identifying the side situated closer to the IR

ANS: A

5. What is the marker placement for the projection of PA oblique vertebrae?
a. Laterally on the side being identified
b. Anteriorly, identifying the side positioned closer to the IR
c. Anywhere within the exposure field
d. Laterally, identifying the side situated closer to the IR

ANS: D

6. What is the marker placement of the projection of lateral hand?




If you need any other Test Banks or eTextbooks contact us:

, a. Laterally on the side being identified
b. Anteriorly, identifying the side positioned closer to the IR
c. Anywhere within the exposure field
d. Laterally, identifying the side situated closer to the IR
ANS: C

7. Which guideline should be used to position the identification (ID) plate?
a. Place the ID plate within the collimated field whenever possible.
b. Position the ID plate toward the direction in which the central ray was angled.
c. Position the ID plate next to the narrowest anatomic structure.

ANS: C

8. Good collimation practices will do all of the following except
a. decrease the radiation dosage.
b. affect the amount of scatter radiation that reaches the IR.
c. reduce the visibility of recorded details.
d. reduce digital radiography histogram analysis errors.
ANS: C

9. Elongation occurs in all of the following situations except when the
a. part is off-center.
b. central ray is angled with the part.
c. central ray and part are perpendicular but the IR is angled.
d. central ray and IR are perpendicular and the part is angled.
ANS: D
10. For an open joint space to be obtained, the central ray must be aligned to the joint.
a. perpendicular
b. parallel
c. 5 degrees cephalic for each 4 inches of tissue thickness
d. 5 degrees caudal for each 4 inches of tissue thickness
ANS: B

11. When the central ray is angled, the structure situated is projected the most.
a. farther away from the IR
b. closer to the IR
c. proximal to the tube
d. distal to the tube

ANS: A

12. Three images were obtained on the same structure with a computed radiography system.
Image 1 was obtained using a 48-inch source–image receptor distance (SID) and a 5-inch
object–image receptor distance (OID); image 2 was obtained using a 48-inch SID and a 3-inch
OID; and image 3 was obtained with a 48-inch SID, a 3-inch OID, and a larger IR. Which
image will demonstrate the sharpest recorded detail?
a. Image 1
b. Image 2




If you need any other Test Banks or eTextbooks contact us:

, c. Image 3
d. There will be no difference in recorded detail.
ANS: B

13. Three images were obtained on the same structure with a computed radiography system.
Image 1 was obtained using a 48-inch source–image receptor distance (SID) and a 5-inch
object–image receptor distance (OID); image 2 was obtained using a 48-inch SID and a 3-inch
OID; and image 3 was obtained with a 48-inch SID, a 3-inch OID, and a larger IR. Which
image will demonstrate the greatest size distortion?
a. Image 1
b. Image 2
c. Image 3
d. There will be no difference in size distortion.

ANS: A

14. A small focal spot should be used for each of the following situations except when
a. fine detail demonstration is important.
b. extremities are imaged.
c. the milliamperage setting is above 300.
d. the patient can control motion.
ANS: C

15. An image demonstrating motion and adequate density was obtained using 100 mA at 0.5
seconds. If the time is changed to 0.25 seconds, what mA should be used to maintain density?
a. 100 mA
b. 200 mA
c. 300 mA
d. 400 mA
ANS: B

16. Anatomical relationships are affected by
1. varying degrees of patient obliquity and flexion.
2. off-centering.
3. geometrical factors of magnification, elongation, and foreshortening.
4. similar structures of shape and size.
a. 1 and 4 only
b. 1, 2, and 4 only
c. 1, 3, and 4 only
d. All of the above
ANS: D

17. Good collimation practices result in which of the following?
1. Reduces histogram analysis errors
2. Clearly delineates the VOI
3. Improves the visibility of recorded details by reducing the amount of scatter radiation that
reaches the IR
4. Decreases the radiation dosage by limiting the amount of scatter from the patient




If you need any other Test Banks or eTextbooks contact us:

Dit zijn jouw voordelen als je samenvattingen koopt bij Stuvia:

Bewezen kwaliteit door reviews

Bewezen kwaliteit door reviews

Studenten hebben al meer dan 850.000 samenvattingen beoordeeld. Zo weet jij zeker dat je de beste keuze maakt!

In een paar klikken geregeld

In een paar klikken geregeld

Geen gedoe — betaal gewoon eenmalig met iDeal, Bancontact of creditcard en je bent klaar. Geen abonnement nodig.

Focus op de essentie

Focus op de essentie

Studenten maken samenvattingen voor studenten. Dat betekent: actuele inhoud waar jij écht wat aan hebt. Geen overbodige details!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper winntampa. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €19,57. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 67418 samenvattingen verkocht

Opgericht in 2010, al 15 jaar dé plek om samenvattingen te kopen

Start met verkopen

Laatst bekeken door jou


€19,57  8x  verkocht
  • (1)
In winkelwagen
Toegevoegd