100% tevredenheidsgarantie Direct beschikbaar na betaling Zowel online als in PDF Je zit nergens aan vast
logo-home
AMT 2 study guide exam 2024/2025 €12,35   In winkelwagen

Tentamen (uitwerkingen)

AMT 2 study guide exam 2024/2025

2 beoordelingen
 145 keer bekeken  2 keer verkocht
  • Vak
  • AMT 2
  • Instelling
  • AMT 2

AMT 2 study guide exam 2024/2025 Amtrak Conductors and Engineer are classified as class ______ employees - CORRECT ANSWER-C. [1.103] Should employees in electrified territory be familiar with the location and operation of radios and telephones? - CORRECT ANSWER-Yes [1.204] When using railroad...

[Meer zien]

Voorbeeld 2 van de 10  pagina's

  • 13 april 2024
  • 10
  • 2023/2024
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • AMT 2
  • AMT 2

2  beoordelingen

review-writer-avatar

Door: mrawf3 • 1 maand geleden

review-writer-avatar

Door: johnborbar1971 • 2 maanden geleden

avatar-seller
AMT 2 study guide exam 2024/2025

Amtrak Conductors and Engineer are classified as class ______ employees -
CORRECT ANSWER-C. [1.103]

Should employees in electrified territory be familiar with the location and operation of
radios and telephones? - CORRECT ANSWER-Yes [1.204]

When using railroad telephone lines or radios, and you hear the word "EMERGENCY"
repeated three times, what must be done? - CORRECT ANSWER-All others using the
phone line or radio channel must yield immediately. [1.205]

All occurrences or conditions which are likely to affect electric Operations must be
reported immediately to whom? - CORRECT ANSWER-The Power Director/Train
Dispatcher. [1.201]

Minimum Approach Distance means? - CORRECT ANSWER-The distance that must be
maintained between personnel and or equipment and all exposed energized lines.
Minimum Approach Distance is measured between the person or the end of a tool,
equipment, or material being used and the exposed energized parts. [1.301]

All overhead wires must be considered energized (Live) at all times except? -
CORRECT ANSWER-When it is known to be de-energized, tested de-energized and
grounded. [1.302]

The third rail must be considered energized (live) at all times except? - CORRECT
ANSWER-When it is known to be de-energized, tested de-energized and a Third Rail
Warning Device is applied. [1.303]

Electric engines and Multiple Units (MU) under overhead wires must be considered
energized (Live) except? - CORRECT ANSWER-When it is known that all Pantographs
are down and Pantograph grounding switches are closed, or overhead wires are de-
energized, tested de-energized and properly grounded. [1.501]

Can employees touch or remove unidentified dangling wires, trees, or foreign objects in
contact with overhead wires or third rail? - CORRECT ANSWER-NO ,employees must
take necessary precautions to protect others and equipment and maintain Minimum
Approach Distance . [1.206]

Conductive material such as steel tape measure, wire, wet or non-rated rope, or linen
tape-line containing metallic reinforcement can be used around energized wire,
apparatus, equipment, or third rail. True or False? - CORRECT ANSWER-False. [1.114]

, The Minimum Approach Distance for AMT-2 Qualified Employees whether or not
protected by Class A employee against Transmission Wires energized or de-energized
and not grounded is? - CORRECT ANSWER-8ft. [Table 1]

What is the Minimum Approach Distance for AMT-2 Qualified Employee whether or not
protected by a Class A employee against the Catenary, Signal Line, and Utility Wires
less than 35000 volts, energized or de-energized and not grounded? - CORRECT
ANSWER-3ft. [Table 1]

What is the Minimum Approach Distance for AMT-2 Qualified Employees against
Transmission Wires for equipment operating in the vicinity of wires energized or de-
energized and not grounded? - CORRECT ANSWER-15ft. [Table 1]

The Minimum Approach Distance for AMT-2 Qualified Employees against Catenary,
Signal Line, Utility Wires Less than 35000 volts for Equipment operating in the vicinity of
wires energized or de-energized and not grounded is/ - CORRECT ANSWER-3ft. [Table
1]

Personnel and Equipment being provided protection by Class A Employee, wires de-
energized, tested de-energized, and grounded will be allowed? - CORRECT ANSWER-
Full Contact. [Table 1]

The Minimum Approach Distance for Unidentified Dangling Wires is? - CORRECT
ANSWER-15ft. [Table 1]

What is the Minimum Approach Distance while walking over and around energized
Third Rail? - CORRECT ANSWER-6 inches. [Table 2]

what is the Minimum Approach Distance for AMT-2 Qualified Employees working with
conductive tools or equipment around Third Rail? - CORRECT ANSWER-4 feet. [Table
2]

The Typical Overhead Wire Profile for the Catenary system starting from The Wire that
contacts the Pantograph are? - CORRECT ANSWER-Contact wire, Auxiliary wire,
Messenger wire, Signal line, Transmission line, Static wire. [Figure 9]

What must be done prior to operating in electrified territory? - CORRECT ANSWER-A
job Briefing. [1.401]

When can Electric Locomotives be routed to tracks protected by a Plate Order? -
CORRECT ANSWER-Ensure that all electric equipment equipped with a Pantograph
(Pantographs) be lowered and locked and/or no third rail shoes are in contact with the
third rail in the area affected by the plate. When the pantograph or third rail shoe cannot
be retracted, the Main Circuit Breaker on the train must be opened and tagged. [2.904
F]

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

√  	Verzekerd van kwaliteit door reviews

√ Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper TIFFACADEMICS. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €12,35. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 72042 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen

Laatst bekeken door jou


€12,35  2x  verkocht
  • (2)
  Kopen