EPA 608 Type 2 Practice Exam Questions With Correct Answers
5 keer bekeken 0 keer verkocht
Vak
EPA 608
Instelling
EPA 608
EPA 608 Type 2 Practice Exam Questions
With Correct Answers
If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be;
A retrofitted or retired within 3 months.
B retrofitted or retired within 12 months.
C replaced within 3 months.
D replaced within 12 months...
EPA 608 Type 2 Practice Exam Questions
With Correct Answers
If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be;
A retrofitted or retired within 3 months.
B retrofitted or retired within 12 months.
C replaced within 3 months.
D replaced within 12 months. - answer✔✔B
retrofitted or retired within 12 months.
A high-pressure appliance containing 210 lbs. of R-407C refrigerant must be evacuated
(recovered) to a level of;
A 15 inches of vacuum
B 10 inches of vacuum
C 4 inches of vacuum
D 0 inches of vacuum - answer✔✔B 10 inches of vacuum
What conditions allow for a system to be opened and repaired without recovering the refrigerant
to the required vacuum level?
A A system with a large leak and internal pressure of 0 psig
B A system that is undergoing a major component replacement
C A system that uses a CFC refrigerant
D A system that has a non-operational compressor - answer✔✔A
A system with a large leak and internal pressure of 0 psig
A crankcase heater is often used to prevent refrigerant from mixing with compressor oil during
periods of:
ALow ambient temperature
B High ambient temperature
D High humidity - answer✔✔A
Low ambient temperature
Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or
greater when the annualized leak rate reaches _____ or more.
A 10%
B 20%
C 30%
D 40% - answer✔✔C
30%
When dehydrating a system, it should be evacuated to a minimum level of;
A 30 inches of Mercury
B 25,000 Microns
C 500 Microns
D EPA does not have a requirement - answer✔✔C
500 Microns
All HVAC/R systems must be protected by a;
A Low-pressure switch
B High-pressure switch
C Compressor impedance overload
D Pressure relief valve - answer✔✔D
Pressure relief valve
Proper recovery techniques begin with the use of appropriate recovery equipment that has been
certified by;
A EPA only
B Manufacturers approved by UL
C EPA approved laboratory
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
√ Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper Thebright. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor €10,18. Je zit daarna nergens aan vast.