Which of the following items should be read first on every lesson? - Answers-
Introductory Information

A competent electrician is one who has ___ , __ , and a positive ___ for his or her trade.
- Answers- skill / knowledge / attitude

The nucleus of what was to become the IBEW was formed in ? in the city of ? . -
Answers- 1890 / St. Louis

The ? Act of 1935 is more commonly referred to as the Wagner Act. - Answers-
National Labor Relations

Worker ? on the job is a major reason that job tasks cannot be performed in a timely
manner. - Answers- Absenteeism

? and ? are critically important to jobsite safety.
a. - Answers- Awareness / common sense

The term ? is used to identify the reference point or angle. - Answers- theta

The side next to the reference angle is called the ? side. - Answers- Adjacent

Since the ratios for sides of triangles are the same, when the angles are the same, ?
have been developed which show these ratios for every angle encountered in a triangle.
- Answers- trigonometric tables

The sine of θ is equal to the ? divided by the ? . - Answers- opposite / hypotenuse

The cos θ is equal to the ? side divided by the ? . - Answers- adjacent / hypotenuse

The tan θ is equal to the ? side divided by the ? side. - Answers- opposite / adjacent

What will happen if the time is not taken to properly measure and lay out a job before
trying to bend conduit? - Answers- I. Additional labor to re-bend
II. Conduit may need to be bent multiple times as a result of inaccurate measurements
IV. Increased amount of scrapped conduit

The only viable method to reduce the material cost itself is to reduce waste, and the
only practical way of doing that is to be skilled in measuring, calculating, and laying out
the conduit bends. - Answers- True

, What tool can be used to prevent an off-axis between bends in an offset (dog-legs)? -
Answers- No-dog level

A lightweight metallic raceway without threads is called ? in the National Electrical
Code. - Answers- Electrical Metallic Tubing

PVC is a form of what type of conduit? - Answers- rigid non-metallic conduit

Match the conduit/size with the appropriate protective cap. - Answers- 1/2" Rigid Metal
Conduit (RMC) → Black
3/4" Rigid Metal Conduit (RMC) → Red
1" Rigid Metal Conduit (RMC) → Blue

According to NEC Section ? , ? shall not be threaded. - Answers- 358.28(B) / EMT

Which types of conduit are typically threaded in order to couple them together or
connect them to boxes or fittings? - Answers- I. IMC
II. RMC

A "plumb 30" or a "plumb 45" bender will reliably produce an approximate 30°- or 45°-
bend when the conduit is horizontal and the handle is pulled up so that the handle is
vertical or plumb. - Answers- True

Note: There are too many variables to rely solely upon the position of the bender handle
to determine the angle of bend. Each bender should be checked initially to verify the
accuracy of the bender markings and the take-up value.

The recommended way to mark a conduit for bending is to place a short pencil or
marker marking where the bend will occur. - Answers- False

When fabricating a 90°-bend, the distance to the bending mark is equal to? - Answers-
The stub-up minus the take-up

Calculate the distance to the reference mark for a 12 3/4-inch stub-up length and match
it to the conduit size. - Answers- 1/2 " → 7 3/4"
3/4" → 6 3/4"
1" → 4 3/4"
1 1/4" → N/A

Choose the value that most closely equals the stub-up length needed for the 1/2-inch
EMT in the photo. Keep in mind that if the measurement is being taken to the side of the
box, instead of the inside of the connector, it will be necessary to subtract a slight
amount (1/16 to1/8 inch) to compensate for the ridge at the bottom of the connector. A
temporarily inserted conduit has been installed for a measurement. - Answers- Even
though it appears that the actual value required is 17 15/16", it is best to shorten the

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

√  	Verzekerd van kwaliteit door reviews

√ Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper GEEKA. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €11,29. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 66579 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€11,29
  • (0)
  Kopen