100% tevredenheidsgarantie Direct beschikbaar na betaling Zowel online als in PDF Je zit nergens aan vast
logo-home
RADIATION SAFETY PRACTICE EXAM QUESTIONS AND ANSWERS €13,19   In winkelwagen

Tentamen (uitwerkingen)

RADIATION SAFETY PRACTICE EXAM QUESTIONS AND ANSWERS

 2 keer bekeken  0 keer verkocht
  • Vak
  • RADIATION
  • Instelling
  • RADIATION

RADIATION SAFETY PRACTICE EXAM QUESTIONS AND ANSWERS

Voorbeeld 2 van de 7  pagina's

  • 8 november 2024
  • 7
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • RADIATION
  • RADIATION
avatar-seller
RADIATION SAFETY PRACTICE EXAM
QUESTIONS AND ANSWERS
The technologist chooses to use a grid for an exam. What effect will this have on the
patient exposure while ensuring proper image quality? - Answer-increase patient
exposure

Which of the following projections would result in a young female patient receiving a
significantly lower dose to her breast tissue during a scoliosis x-ray? - Answer-
Posteroanterior (PA)

What is the most effective and often used material in protective barriers? - Answer-Lead

Which of the following should be avoided if possible when imaging morbidly obese
patients using direct radiography (DR) image receptors? - Answer-The use of full
17x17" radiation field

During fluoroscopy, the Bucky tray is moved to the end of the examination table, leaving
an opening in the side of the table approximately two inches wide at the gonadal level.
This opening must be automatically covered with at least: - Answer-0.25 mm lead
equivalent material

The main purpose of adding filtration to the x-ray tube is to - Answer-decrease patient
dose

Which of the following would provide fluoroscopic imaging personnel with the BEST
radiation protection opportunity? - Answer-Controlling the fluoroscopic system remotely

Federal law on radiation protection requires which two of the following? - Answer-
Signage for radiation areas, maintaining personnel dose records

A shallow dose refers to which of the following? - Answer-Surface dose

For a mobile or portable fluoroscopic equipment (C-arm), inherent provisions must be
made so that the machine cannot be operated at less than: - Answer-12 inches (30 cm)
source-to-skin distance (SSD)

Which of the following beam restriction devices is the most versatile for defining the size
and shape of the radiographic beam? - Answer-Collimator

What is the annual dose equivalent limit for the lens of the eye for occupational
workers? - Answer-150 millisieverts (mSv)

, The National Council for Radiatin Protection and Measurement (NCRP) requires that
leakage radiation from the fluoroscopic tube must be below: - Answer-1 milligray/hour at
1 meter from the tube

A patient in the emergency department requires a mobile chest x-ray. What effort would
BEST reduce radiation exposure to the technologist? - Answer-standing 6 feet from the
x-ray tube during the exposure

What effect will decreasing collimation (larger exposure field) have on the patient's
effective dose when using a fixed technique - Answer-increases patient effective dose

Radiation dose reduction that is a result of using protective shielding is based on which
two of the following? - Answer-Material of the shield, thickness of the shield

Which of the following is the most commonly used beam restricting device? - Answer-
collimator

Increasing diagnostic filtration results in which three of the following? - Answer-
decreased patient dose, decreased contrast, decreased image receptor exposure

Fluoroscopic units display the radiation quantity used for the procedure as: - Answer-air
kerma

According to National Council on Radiation Protection and Measurement (NCRP)
guidelines, a medical x-ray tube must include aluminum equivalent filtration equal to a
minimum of: - Answer-2.5mm

What effect does decreaseing the primary beam field size (increasing collimation) have
on the amount of scatter radiation reaching the image receptor (IR)? - Answer-
decreases amount of scatter radiation reaching the IR

What is the annual dose equivalent limit for a radiographer's hands? - Answer-500
millisieverts (mSv)

Which of the following may alert fluoroscopic x-ray production after a preset period of
time? - Answer-Cumulative timer

Expectant mothers who are technologists should wear a fetal dosimeter at what
location? - Answer-at the waist

What thickness of protective shielding is required in the Bucky slot cover of a
fluoroscopic imaging unit? - Answer-0.25 mm lead equivalent

According to the National Council on Radiation Protection and Measurements (NCRP),
total filtration that is permanently fixed in the useful beam for fluoroscopic equipment

Voordelen van het kopen van samenvattingen bij Stuvia op een rij:

√  	Verzekerd van kwaliteit door reviews

√ Verzekerd van kwaliteit door reviews

Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!

Snel en makkelijk kopen

Snel en makkelijk kopen

Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.

Focus op de essentie

Focus op de essentie

Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper biggdreamer. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor €13,19. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 78252 samenvattingen verkocht

Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen

Start met verkopen
€13,19
  • (0)
  Kopen