2022/2023

PEACE model correct answer: Planning, Event, Assess, Communicate, Enviroment STARR Model correct answer: Spread out, Transfer, Avoid, Accept, Reduce How many nicked wires are allowed in a conductor with 19 strands of wire per conductor? correct answer: 2 Nicked, None Broken or Severed What type of harness is preferred for maintenance considerations and why is it preferred? correct answer: Open harnesses are preferred for maintenance considerations. The wires or cables within the harness are uncovered which enables visual inspection and ease of repair when necessary. What is the MINIMUM clearance when wiring must be routed parallel to flammable lines for short distance and a 6 inch clearance cannot be maintained? correct answer: the bundle and flammable line shall be clamped with 2" minimum, so that there will be no relative motion between them. When a two inch clearance cannot be maintained, the bundle shall be clamped....The minimum clearance shall be 1/2 inch. Route the wires on a level with, or above, the plumbing lines. Space clamps so that if a wire is broken at a clamp it will not contact the line. What is the MAXIMUM wiring bend radius for a wire group, bundle or harness? correct answer: 10 time the diameter of the largest wire.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

AET2 SWE| 149 questions| with
complete solutions
PEACE model correct answer: Planning, Event, Assess, Communicate, Enviroment
STARR Model correct answer: Spread out, Transfer, Avoid, Accept, Reduce
How many nicked wires are allowed in a conductor with 19 strands of wire per conductor? correct answer: 2 Nicked, None Broken or Severed
What type of harness is preferred for maintenance considerations and why is it preferred? correct answer: Open harnesses are preferred for maintenance considerations. The wires or cables within the harness are uncovered which enables visual inspection and ease of repair when necessary.
What is the MINIMUM clearance when wiring must be routed parallel to flammable lines for short distance and a 6 inch clearance cannot be maintained? correct answer: the bundle and
flammable line shall be clamped with 2" minimum, so that there will be no relative motion between them.
When a two inch clearance cannot be maintained, the bundle shall be clamped....The minimum clearance shall be 1/2 inch. Route the wires on a level with, or above, the plumbing lines. Space clamps so that if a wire is broken at a clamp it will not contact the line. What is the MAXIMUM wiring bend radius for a wire group, bundle or harness? correct answer: 10 time the diameter of the largest wire.
What is step (a) of the general precautions for lacing or tying wire groups or bundles? correct answer: Lace or tie bundles tightly enough to prevent slipping, but not so tightly that the cord or tape cuts into or deforms the insulation. Be especially careful when lacing or tying coaxial cable, which has a soft dielectric insulation between the inner and outer conductors.
When is zip ties authorized to secure wire groups/bundles? correct answer: The use of plastic cable straps is strictly prohibited in all instances (refer to AS50881).
Which five heating tools are authorized to use on aircraft? correct answer: HT-900B, HT-920B, HT-71002, M and IR -
1759.
Which heating tools are authorized for the internal repair of fuel tanks and fuel cells? correct answer: The HT-900B, HT-920B, HT-71002, MC H-100-A and IR-1759 are the only authorized heat guns to be used when working on aircraft that have not been defueled and purged.
What is the MAXIMUM number of terminal lugs per post? correct answer: 4 terminal lugs per terminal post
Which wire size (AWG) should be used with a red terminal lug?
correct answer: Red 22-18 AWG What is the correct strip length for #22 AWG wire, when stripping length for small copper terminal lugs? correct answer: 6/32"
According to the NAVAIR 01-1A-505-1, Wire size with AWG of ___ and larger, shall be replaced in its entirety instead of being repaired? correct answer: WP14
What is used as an inspection aid during shield termination installation? correct answer: WP15
Which shield termination class is the only class authorized for military use? correct answer: WP15
List the characteristics of an unacceptable (overheated). correct answer: WP15
Which two letters identify terminal boards? correct answer: WP19
According to WP19 of the NAVAIR 01-1A-505-1, how should terminal lugs with various diameters be stacked? correct answer:
WP19
Summarize the meaning of the "WARNING" on Cadmium plate
material. correct answer: The use of cadmium has been restricted and/or banned for use in many countries due to environmental and health concerns.
List three different types of connector couplings. correct answer:
threaded, bayonet, breech, or push pull

Geschreven voor

Instelling
Vak

Documentinformatie

Geüpload op
27 april 2023
Aantal pagina's
20
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€12,12
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Classroom NURSING
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
4811
Lid sinds
3 jaar
Aantal volgers
3227
Documenten
54598
Laatst verkocht
3 uur geleden
NURSING

Assignments, Case Studies, Research, Essay writing service, Questions and Answers, Discussions etc. for students who want to see results twice as fast. I have done papers of various topics and complexities. I am punctual and always submit work on-deadline. I write engaging and informative content on all subjects. Send me your research papers, case studies, psychology papers, etc, and I’ll do them to the best of my abilities. Writing is my passion when it comes to academic work. I’ve got a good sense of structure and enjoy finding interesting ways to deliver information in any given paper. I love impressing clients with my work, and I am very punctual about deadlines. Send me your assignment and I’ll take it to the next level. I strive for my content to be of the highest quality. Your wishes come first— send me your requirements and I’ll make a piece of work with fresh ideas, consistent structure, and following the academic formatting rules. For every student you refer to me with an order that is completed and paid transparently, I will do one assignment for you, free of charge!!!!!!!!!!!!

Lees meer Lees minder
4,0

1176 beoordelingen

5
622
4
214
3
192
2
39
1
109

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen