NEIEP Chapter 505 question n answers graded A+
NEIEP Chapter 505__________ contain and protect the wiring between component parts of the installation. - correct answer Raceways The __________ __________ __________ is a broad code regulating all electrical work in the United States from house wiring to factories and other large buildings. - correct answer National Electrical Code An installation is usually divided into three sections - __________ __________ , _________ , and __________. - correct answer machine room, hoistway; car Vertical wireways shall be securely supported at intervals not exceeding __________ feet and shall have no more than __________ joint between supports. - correct answer 15; 1 The bends in a run of EMT between access points shall not exceed __________ degrees. - correct answer 360 The __________ __________ on a thin wall bender locates the finish line of a back to back bend. - correct answer star point A three bend saddle consists of a __________ degree bend approaching the obstacle, a __________ degree bend around the obstacle, and another __________ degree bend to return the conduit to the extension of its original centerline. - correct answer 22 1/2; 45; 22 1/2 Other information will sometimes only be found on the __________. This includes the approved type hall fixtures, car panel, car lighting, and other vital data. The __________ also shows the main and alternate fire service floors. Any additional special features will also be found on the __________. - correct answer abstract What is the point where each wire is connected called? - correct answer Terminal A __________ may be a stud, screw, wire wrap, taper tab, or any other type of connection means. - correct answer terminal Where multiple traveling cables are installed, each cable is __________ so it can be identified. - correct answer numbered The closest traveling cable to the rail is number __________, the next is number __________, and so on. - correct answer one; two __________ ___________ diagrams are like a road map. You can begin tracing the path of an electrical circuit at the positive or the negative side of the drawing and follow the path to the opposite side. - correct answer Straight line According to the NEC, the interlocks must be wired with __________ __________ wire. - correct answer flame retardant Wire sizes larger than 4/0 are designated in __________ __________. - correct answer circular mils Operating and control circuits cannot use wire smaller than __________ AWG in traveling cables and not smaller than __________ AWG outside of the traveling cables. - correct answer 20; 24
Geschreven voor
- Instelling
- Neiep
- Vak
- Neiep
Documentinformatie
- Geüpload op
- 15 april 2024
- Aantal pagina's
- 2
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Onbekend
Onderwerpen
-
neiep chapter 505
Ook beschikbaar in voordeelbundel