Larger capacity, high pressure fuel trains are - Answer-more complex 
 
The main burner test firing valve should be opened - Answer-before starting the main burner 
 
What is the recommended boiler water pH for wet layup? - Answer-10 
 
R4B Failure to _____ the furnace thoroughly before light-up can cause a furnace explosion. - Answer-purge 
 
R4B When cooling down a steam boiler that has been taken out of service, a vent valve on a steam drum ...
-
4th TSSA Part A Unit 1 Exam Questions and Answers
- Exam (elaborations) • 9 pages • 2023
- Available in package deal
-
- $12.09
- + learn more
4th TSSA Part A Unit 1 Exam Questions and Answers
-
4th TSSA Part A Unit 1 Exam Questions and Answers
- Exam (elaborations) • 9 pages • 2024
-
Available in package deal
-
- $8.99
- + learn more
4th TSSA Part A Unit 1 
Exam Questions and 
Answers 
 
(4-009-2.3) The ability of a body to do work due to its motion is called ____________ 
energy. - Answer-Kinetic 
(4-009-1.7) The change of position (in meters) per unit time is: - Answer-Velocity 
(4-015-1.5) The force of friction is: - Answer-Not affected by the area of the two surfaces 
in contact. 
(4-012-1.11) With reference to scalars and vectors, a space diagram: - AnswerIllustrates a system of vectors. 
(4-016-3.3) A 1.5m long round b...
-
4th TSSA Part B Unit 4 Exam Questions and Answers
- Exam (elaborations) • 7 pages • 2023
-
- $9.99
- + learn more
4th TSSA Part B Unit 4 
Exam Questions and 
Answers 
 
Larger capacity, high pressure fuel trains are - Answer-more complex 
The main burner test firing valve should be opened - Answer-before starting the main 
burner 
What is the recommended boiler water pH for wet layup? - Answer-10 
R4B Failure to _____ the furnace thoroughly before light-up can cause a 
furnace explosion. - Answer-purge 
R4B When cooling down a steam boiler that has been taken out of service, 
a vent valve on a steam drum sh...
Make study stress less painful
-
Test bank for 4th TSSA Part A & B Unit 4 Exam Questions and Answers.
- Package deal • 2 items • 2023
-
- $19.96
- + learn more
Exam (elaborations)
4th TSSA Part A Unit 1 Exam Questions and Answers

Exam (elaborations)
4th TSSA Part B Unit 4 Exam Questions and Answers.
-
4th TSSA Part B Unit 4 Exam Questions and Answers
- Exam (elaborations) • 7 pages • 2023
-
Available in package deal
-
- $10.99
- + learn more
4th TSSA Part B Unit 4 
Exam Questions and 
Answers 
 
Larger capacity, high pressure fuel trains are - Answer-more complex 
The main burner test firing valve should be opened - Answer-before starting the main 
burner 
What is the recommended boiler water pH for wet layup? - Answer-10 
R4B Failure to _____ the furnace thoroughly before light-up can cause a 
furnace explosion. - Answer-purge 
R4B When cooling down a steam boiler that has been taken out of service, 
a vent valve on a steam drum sh...
-
TSSA 4th Part B - Unit 9 Exam Latest Update
- Exam (elaborations) • 8 pages • 2024
-
- $8.99
- + learn more
TSSA 4th Part B - Unit 9 Exam Latest Update ...
-
4th TSSA Part B Unit 4 Exam Questions and Answers
- Exam (elaborations) • 7 pages • 2023
-
- $10.89
- + learn more
4th TSSA Part B Unit 4 
Exam Questions and 
Answers 
 
Larger capacity, high pressure fuel trains are - Answer-more complex 
The main burner test firing valve should be opened - Answer-before starting the main 
burner 
What is the recommended boiler water pH for wet layup? - Answer-10 
R4B Failure to _____ the furnace thoroughly before light-up can cause a 
furnace explosion. - Answer-purge 
R4B When cooling down a steam boiler that has been taken out of service, 
a vent valve on a steam drum sh...
-
4th TSSA Part A (I) Questions with 100% answers.
- Exam (elaborations) • 10 pages • 2024
-
Available in package deal
-
- $11.49
- + learn more
4th TSSA Part A (I) 
Questions with 100% answers. 
 
A process flow diagram (PFD) shows: - Major piping to do with a process 
 
(4-017-1.1) Which of the following statements about belt drive systems is FALSE? - Tension in the bottom belt is always double that in the top belt. 
 
(4-001-1.9) Power engineers can usually expect to work: - Rotating shifts 
 
(4-117-2.4) The refrigeration condenser design that requires the tubes to be cleaned with acid and then neutralized, is the: - Shell and coil c...