Overcurrent protection - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Overcurrent protection? On this page you'll find 623 study documents about Overcurrent protection.

Page 4 out of 623 results

Sort by

TRANSFORMERS NIVEL DOS: REVENGE OF THE XFRMR OCPD W/ ASSOC. TAP RULES
  • TRANSFORMERS NIVEL DOS: REVENGE OF THE XFRMR OCPD W/ ASSOC. TAP RULES

  • Exam (elaborations) • 6 pages • 2024
  • In general, transformer secondary conductors are not considered to be protected by the primary overcurrent protective device. TRUE 240.4(F) An installation consists of a 10-kVA, single-phase transformer with a 440-volt primary and a 110-volt, 2-wire secondary using THWN copper conductors. No secondary OCPD is installed. The secondary loads are considered to be noncontinuous loads. Calculate the minimum size secondary conductors required to handle the secondary full-load current for this transf...
    (0)
  • $11.49
  • + learn more
NEC Master practice test 100% Correct!!
  • NEC Master practice test 100% Correct!!

  • Exam (elaborations) • 41 pages • 2024
  • If two 10-ohm resistors are connected in series, what is the total resistance of these resistors? - ANSWER20 ohms In a split-phase motor, how much greater is the starting current when compared to the full-load current? - ANSWER6 to 8 times The terminals of a motor can be identified using a battery and a ___ - ANSWERvoltmeter A 5-ohm and a 20-ohm resistor are connected in parallel. What is the total resistance of these two resistors? - ANSWER4 ohms The normal location to provide overcurrent p...
    (0)
  • $15.99
  • + learn more
Journeyman Electrician #4 Exam 100% Correct!!
  • Journeyman Electrician #4 Exam 100% Correct!!

  • Exam (elaborations) • 8 pages • 2024
  • Available in package deal
  • Where conduits enter a floor-standing switchboard or panelboard at the bottom, the conduits including their end fittings, shall not rise more than _____ above the bottom of the enclosure. a) 6 inches b) 4 inches c) 2 inches d) 3 inches - ANSWERD: 3 inches Ref: 408.5 When installed on the service of a building or structure, a type 2 SPD (TVSS) shall be connected _____. a)on the line side of the service disconnect overcurrent device b) on the load side of the service disconnect overc...
    (0)
  • $15.49
  • + learn more
IEC 4th Year Final Questions And Answers 100% Guaranteed Success.
  • IEC 4th Year Final Questions And Answers 100% Guaranteed Success.

  • Exam (elaborations) • 20 pages • 2024
  • IEC 4th Year Final Questions And Answers 100% Guaranteed Success. Duty on escalator and moving walk driving machine motors shall be rated as ___. Select one: a. continuous b. intermittent c. varying d. periodic e. short-time - correct answer. a. continuous Each carnival ride and concession shall be provided with a fused disconnect switch located within sight of and within ___ feet of the operator's station. Select one: a. 8 b. 10 c. 6 d. 25 e. 50 - correct answer....
    (0)
  • $10.49
  • + learn more
How to Perform Residential Electrical Inspections Course questions with correct answers
  • How to Perform Residential Electrical Inspections Course questions with correct answers

  • Exam (elaborations) • 19 pages • 2023
  • Available in package deal
  • A live wire is sometimes called a(n) __________. grounded conductor ungrounded conductor grounding conductor CORRECT ANSWER ungrounded conductor Branch circuit conductors are the ____________. wires to the outlets receptacle wires without insulation amp suppliers CORRECT ANSWER wires to the outlets For a 14-gauge copper wire, the maximum overcurrent protection rating is _____ amps. 30 15 20 CORRECT ANSWER 15 The following item is safe to insert into an electrical...
    (0)
  • $14.49
  • + learn more
ABYC Electrical Exam Questions And Correct Answers(2024 Latest Update)(Rated A+)
  • ABYC Electrical Exam Questions And Correct Answers(2024 Latest Update)(Rated A+)

  • Exam (elaborations) • 41 pages • 2024
  • Which tool is most approprite to clean battery connections? A. B. C. D. - ANSWER The minimum amp circuit breaker that should be used to protect 120V water heater circuit with a 1600-watt element would be rated at _________ amps. A. 15 B. 10 C. 20 D. 30 - ANSWER A. 15 When testing for excessive EMF emissions near a conductor or appliance, the tool of choice is a(an): A. Ohmmeter B. DVOM C. Gauss meter D. infrared sensor - ANSWER C. Gauss meter The primary problem with using a series circuit to su...
    (0)
  • $9.99
  • + learn more
GROUND & BONDING II STUDY QUESTIONS AND ANSWERS
  • GROUND & BONDING II STUDY QUESTIONS AND ANSWERS

  • Exam (elaborations) • 8 pages • 2024
  • A grounding electrode system is generally required for each building or structure served by a feeder - Answer-true Where a building or structure is supplied by an ungrounded system, the feeder from the ungrounded system must include an equipment grounding condcutor or supply-side bonding jumper with the conductors to the building disconnecting means, and it must be connected to the disconnecting means enclosure as well as the grounding electrode conductor - Answer-true NEC ____ provides th...
    (0)
  • $12.49
  • + learn more
Residential Wiring Final Exam Review || 100% verified answers.
  • Residential Wiring Final Exam Review || 100% verified answers.

  • Exam (elaborations) • 9 pages • 2024
  • Available in package deal
  • A(n) _______ is the circuit conductors between the final overcurrent device and the outlets. open circuit branch circuit feeder circuit service conductor correct answers branch circuit The circuit conductors between the service equipment and the final branch circuit overcurrent protection device is a(n) open circuit branch circuit feeder circuit service conductor correct answers feeder circuit When doing service entrance calculations, 1 volt-ampere equals 1 joule 1 watt 1 ohm 1...
    (0)
  • $11.39
  • + learn more
2024 Residential Wiring Final Exam Review Complete Questions And Answers With Verified Solutions
  • 2024 Residential Wiring Final Exam Review Complete Questions And Answers With Verified Solutions

  • Exam (elaborations) • 14 pages • 2024
  • Available in package deal
  • A(n) _______ is the circuit conductors between the final overcurrent device and the outlets. open circuit branch circuit feeder circuit service conductor - Answer-branch circuit The circuit conductors between the service equipment and the final branch circuit overcurrent protection device is a(n) open circuit branch circuit feeder circuit service conductor - Answer-feeder circuit When doing service entrance calculations, 1 volt-ampere equals 1 joule 1 watt 1 ohm 1 mil - Answer-1 w...
    (0)
  • $7.99
  • + learn more
Journeyman Electrician #4 Exam Questions and Answers
  • Journeyman Electrician #4 Exam Questions and Answers

  • Exam (elaborations) • 11 pages • 2024
  • Available in package deal
  • Journeyman Electrician #4 Exam Questions and Answers Where conduits enter a floor-standing switchboard or panelboard at the bottom, the conduits including their end fittings, shall not rise more than _____ above the bottom of the enclosure. a) 6 inches b) 4 inches c) 2 inches d) 3 inches -Answer-D: 3 inches Ref: 408.5 When installed on the service of a building or structure, a type 2 SPD (TVSS) shall be connected _____. a)on the line side of the service disconnect overcurrent device ...
    (0)
  • $12.49
  • + learn more