Evitp load calculations - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Evitp load calculations? On this page you'll find 7 study documents about Evitp load calculations.

All 7 results

Sort by

EVITP Load calculation Feeders and services Level 4 Module 1 Questions and Answers 100% Correct
  • EVITP Load calculation Feeders and services Level 4 Module 1 Questions and Answers 100% Correct

  • Exam (elaborations) • 4 pages • 2024
  • EVITP Load calculation Feeders and services Level 4 Module 1 Questions and Answers 100% Correct
    (0)
  • $12.99
  • + learn more
EVITP Load Calculation Feeders And Services Level 4 Module 1: Questions With Complete Answers
  • EVITP Load Calculation Feeders And Services Level 4 Module 1: Questions With Complete Answers

  • Exam (elaborations) • 3 pages • 2024
  • EVITP Load Calculation Feeders And Services Level 4 Module 1: Questions With Complete Answers
    (0)
  • $8.99
  • + learn more
EVITP: Load Calculations: Feeders and Services Exam Questions with 100% Correct Answers | Latest Version 2024 | Verified
  • EVITP: Load Calculations: Feeders and Services Exam Questions with 100% Correct Answers | Latest Version 2024 | Verified

  • Exam (elaborations) • 12 pages • 2024
  • What NEC Article covers feeder circuits? NEC Article 215 3 multiple choice options The conductors and equipment for delivering electric energy from the serving utility to the wiring system of the premises served is a? Service 3 multiple choice options The overhead conductors between the utility electric supply system and the service point is _____? Service drop 3 multiple choice options What sections make up electrical Calculations? Feeders, Services, & Branch Circuits 3 multiple ch...
    (0)
  • $11.00
  • + learn more
26401 EVITP: Load Calculations - Feeders and Services Exam Questions with Correct Answers | Latest Version 2024 | Verified
  • 26401 EVITP: Load Calculations - Feeders and Services Exam Questions with Correct Answers | Latest Version 2024 | Verified

  • Exam (elaborations) • 11 pages • 2024
  • Load calculated at 2 circuit 1500VA. - Small Appliance Ciruit Voltage drop formula 1 VD = (2*L*R*I)/1,000 - VD = voltage drop (in volts) L = load center or total length in feet R = conductor resistance per NEC Chapter 9, Table 8 I = current The number 1,000 represents 1,000' or less of conductor. Show window loads should be calculated at _____ per linear foot of show window. - 200VA What is the minimum demand required for the portion of a feeder that supplies 30' of show windows? 6,...
    (0)
  • $11.00
  • + learn more
26401 EVITP: Load and Feeder Calculations Exam Questions with 100% Correct Answers | Latest Version 2024 | Verified
  • 26401 EVITP: Load and Feeder Calculations Exam Questions with 100% Correct Answers | Latest Version 2024 | Verified

  • Exam (elaborations) • 11 pages • 2024
  • What is the minimum demand required for the portion of a feeder that supplies 30ft of show window? 30ft x 200va = 6000 va Residential Small apliance circuits must be rated at __________ per NEC 220.52(A) 1500 va When performing load calculations for farm buildings the load that must be included in the calculation at 100% demand must be at least _______ . 60 amps The demand lighting load for a 20,000 square foot motel with no dining room or ballroom is ____ per NEC 220.12 and 220.42 18...
    (0)
  • $11.00
  • + learn more
NCCER 26401 EVITP: Load Calculations - Feeders and Services Exam Questions with 100% Correct Answers | Latest Version 2024 | Verified
  • NCCER 26401 EVITP: Load Calculations - Feeders and Services Exam Questions with 100% Correct Answers | Latest Version 2024 | Verified

  • Exam (elaborations) • 3 pages • 2024
  • The smallest size locking and grounding type receptacle that may be used to provide shore power for boats is _____. - 30A A commercial kitchen with more than six pieces of kitchen equipment is subject to a demand factor of _____. - 65% What is the load for 40 non-dwelling unit receptacles? (Assume that the load is not continuous.) - 7,200VA Refer to the figure provided. What is the total load of a feeder serving four 230V motors rated 5hp, 15hp, 20hp, and 40hp? - 241.2A The demand lighti...
    (0)
  • $10.00
  • + learn more
EVITP: LOAD CALCULATION FEEDERS AND SERVICES LEVEL 4 MODULE 1|EVITP ACTUAL FINAL EXAM|LATEST UPDATE 2024-2025|BRAND NEW EXAM QUESTIONS AND CORRECT ANSWERS ALL GRADED A+|GUARANTEED SUCCESS.
  • EVITP: LOAD CALCULATION FEEDERS AND SERVICES LEVEL 4 MODULE 1|EVITP ACTUAL FINAL EXAM|LATEST UPDATE 2024-2025|BRAND NEW EXAM QUESTIONS AND CORRECT ANSWERS ALL GRADED A+|GUARANTEED SUCCESS.

  • Exam (elaborations) • 9 pages • 2024
  • EVITP: LOAD CALCULATION FEEDERS AND SERVICES LEVEL 4 MODULE 1|EVITP ACTUAL FINAL EXAM|LATEST UPDATE |BRAND NEW EXAM QUESTIONS AND CORRECT ANSWERS ALL GRADED A+|GUARANTEED SUCCESS. What is the demand factor allowed by the NEC® for calculating the neutral conductor size for electric range load? - ANSWER-70% Using the VA/linear foot method, the total VA that must be used in a service calculation for a 50' show window is - ANSWER-12,500VA Before it is considered a continuous load,...
    (0)
  • $13.49
  • + learn more